An RF breast coil for 0.2TMRI: RF Breast Coil for 0.2T MRI

Breast cancer is the most frequently diagnosed cancer in women. High field studies have shown the diagnostic value of breast MRI, but the examination costs greatly exceed those of competing conventional mammography. Low field MRI offers typical MRI contrast at substantially lower cost, but has suffered from lower spatial resolution. Specificity of breast MRI can potentially be increased by acquiring MR imaging with higher spatial or temporal resolution, but the signal-to-noise ratio (SNR) achievable in a given imaging time becomes limiting. SNR for the particular pulse sequence and magnet field strength is strongly influenced by the characteristics of the radio-frequency coil. An optimal breast coil should yield excellent SNR but also generate a homogeneous B1 field, while allowing imaging of the both breasts simultaneously and maintaining patient comfort. RF receiver coil design is a key determinant of image quality, thus to address this we have designed and constructed a low field breast imaging coil. The coil was tested with a 4-post 0.2T MRI providing high quality breast images. Designed and constructed saddle rf coil allows to obtain good quality image of the breast using low 0.2 T MRI system within 2 minutes. The coil provides patient comfort as breast compression is not required and minimizes artefacts caused by respiration or motion. A high contrast, low-cost and pain-free breast examination using optimized low field MRI system has the potential to serve a large patient population for whom current technologies have deficiencies. © 2015 Wiley Periodicals, Inc. Concepts Magn Reson Part B (Magn Reson Engineering), 2015

[1]  E Atalar,et al.  Switchable multicoil array for MR micro‐imaging of breast lesions , 1999, Magnetic resonance in medicine.

[2]  S. Zangos,et al.  MR-guided biopsies with a newly designed cordless coil in an open low-field system: Initial findings , 2006, European Radiology.

[3]  Localization and biopsy of breast lesions by magnetic resonance imaging guidance , 2001, Journal of magnetic resonance imaging : JMRI.

[4]  J O Olsen,et al.  Design and optimization of a breast coil for magnetic resonance imaging. , 1993, Magnetic resonance imaging.

[5]  M D Schnall,et al.  MR imaging of the breast for the detection, diagnosis, and staging of breast cancer. , 2001, Radiology.

[6]  J T Ennis,et al.  Breast disease: tissue characterization with Gd-DTPA enhancement profiles. , 1990, Radiology.

[7]  C. Boetes,et al.  MRI screening for breast cancer in women with familial or genetic predisposition: design of the Dutch National Study (MRISC) , 2001, Familial Cancer.

[8]  Breast coil design for low‐field mri , 1992, Magnetic resonance in medicine.

[9]  T. Wolfson,et al.  The efficacy of breast MRI in predicting breast conservation therapy , 2006, Journal of surgical oncology.

[10]  S. Heywang,et al.  MR imaging of the breast with Gd-DTPA: use and limitations. , 1989, Radiology.

[11]  V. Jackson,et al.  The current role of ultrasonography in breast imaging. , 1995, Radiologic clinics of North America.

[12]  S. Plevritis,et al.  Breast magnetic resonance image screening and ductal lavage in women at high genetic risk for breast carcinoma , 2004, Cancer.

[13]  W. Rubinstein,et al.  Prospective screening study of 0.5 Tesla dedicated magnetic resonance imaging for the detection of breast cancer in young, high-risk women , 2006, BMC women's health.

[14]  S E Harms,et al.  MR imaging of the breast with rotating delivery of excitation off resonance: clinical experience with pathologic correlation. , 1993, Radiology.

[15]  H. Degani,et al.  Phosphocholine as a biomarker of breast cancer: Molecular and biochemical studies , 2007, International journal of cancer.

[16]  Ellen Warner,et al.  Surveillance of BRCA1 and BRCA2 mutation carriers with magnetic resonance imaging, ultrasound, mammography, and clinical breast examination , 2004, JAMA.

[17]  C. Boetes,et al.  Breast MRI: guidelines from the European Society of Breast Imaging , 2008, European Radiology.

[18]  R. Weissleder,et al.  Imaging in the era of molecular oncology , 2008, Nature.

[19]  D I Hoult,et al.  Probe with chest shielding for improved breast MRI , 2000, Magnetic resonance in medicine.

[20]  S E Harms,et al.  Magnetic resonance imaging of the breast. , 1992, Magnetic resonance quarterly.

[21]  P. L. Davis,et al.  Sensitivity of enhanced MRI for the detection of breast cancer: new, multicentric, residual, and recurrent , 1997, European Radiology.

[22]  Dmitri Artemov,et al.  MR molecular imaging of the Her‐2/neu receptor in breast cancer cells using targeted iron oxide nanoparticles , 2003, Magnetic resonance in medicine.

[23]  M D Schnall,et al.  Suspicious breast lesions: MR imaging with radiologic-pathologic correlation. , 1994, Radiology.

[24]  W. Kaiser,et al.  MR imaging of the breast: fast imaging sequences with and without Gd-DTPA. Preliminary observations. , 1989, Radiology.

[25]  Carlos Ernesto Garrido Salmon,et al.  Optimization of saddle coils for magnetic resonance imaging , 2006 .

[26]  E. Pääkkö,et al.  Low-field versus high-field MRI in diagnosing breast disorders , 2005, European Radiology.

[27]  Deborah Rhodes,et al.  Molecular breast imaging , 2009, Expert review of anticancer therapy.

[28]  Rankin Sc,et al.  MRI of the breast. , 2000 .

[29]  L. Baker,et al.  Breast cancer detection demonstration project: Five‐year summary report , 1982, CA: a cancer journal for clinicians.

[30]  B. Tomanek,et al.  An optimized solenoidal head radiofrequency coil for low-field magnetic resonance imaging. , 2009, Magnetic resonance imaging.

[31]  M D Schnall,et al.  Multicoil array for high resolution imaging of the breast , 1997, Magnetic resonance in medicine.

[32]  C. Gatsonis,et al.  MRI evaluation of the contralateral breast in women with recently diagnosed breast cancer. , 2007, The New England journal of medicine.

[33]  S E Harms,et al.  MR imaging of the breast , 1993, Journal of magnetic resonance imaging : JMRI.

[34]  T. Helbich,et al.  Contrast-enhanced magnetic resonance imaging of the breast. , 2000, European journal of radiology.