Interaction and aggregated modeling of multiple paralleled inverters with LCL filter

This paper discusses the dynamic interaction of multi-paralleled inverters within a weak grid. Interactive current and common current models are proposed to explain the interaction among these inverters, which are studied with both open loop and closed loop analysis. An aggregated model is proposed to describe the totality of multi-inverters. Additionally, system stability is explicitly studied and classified as interactively and commonly stable. The study is validated by simulations and experiments.

[1]  Guan-Chyun Hsieh,et al.  Phase-locked loop techniques. A survey , 1996, IEEE Trans. Ind. Electron..

[2]  Rui Li,et al.  Influence of Delay on System Stability and Delay Optimization of Grid-Connected Inverters With LCL Filter , 2014, IEEE Transactions on Industrial Informatics.

[3]  F. Blaabjerg,et al.  Power electronics as efficient interface in dispersed power generation systems , 2004, IEEE Transactions on Power Electronics.

[4]  D. G. Holmes,et al.  Optimized Design of Stationary Frame Three Phase AC Current Regulators , 2009, IEEE Transactions on Power Electronics.

[5]  Donald Grahame Holmes,et al.  Regions of active damping control for LCL filters , 2012, 2012 IEEE Energy Conversion Congress and Exposition (ECCE).

[6]  D.G. Infield,et al.  Power quality from multiple grid-connected single-phase inverters , 2004, IEEE Transactions on Power Delivery.

[7]  Poh Chiang Loh,et al.  Exploring inherent damping characteristic of LCL-filters for three-phase grid-connected voltage source inverters , 2010, 2010 IEEE Energy Conversion Congress and Exposition.

[8]  P.J.M. Heskes,et al.  Harmonic interaction between a large number of distributed power inverters and the distribution network , 2004, IEEE Transactions on Power Electronics.

[9]  C.M. Johnson,et al.  Low order harmonic cancellation in a grid connected multiple inverter system via current control parameter randomization , 2005, IEEE Transactions on Power Electronics.

[10]  Thomas Ellinger,et al.  Dynamic Interaction Analysis of APF Systems , 2014, IEEE Transactions on Industrial Electronics.

[11]  Yun Wei Li,et al.  Investigation and Active Damping of Multiple Resonances in a Parallel-Inverter-Based Microgrid , 2013, IEEE Transactions on Power Electronics.

[12]  Bangyin Liu,et al.  Stability Analysis of Grid-Connected Inverter With LCL Filter Adopting a Digital Single-Loop Controller With Inherent Damping Characteristic , 2013, IEEE Transactions on Industrial Informatics.

[13]  Ian Postlethwaite,et al.  Multivariable Feedback Control: Analysis and Design , 1996 .

[14]  Paolo Mattavelli,et al.  Digital Control in Power Electronics , 2006, Digital Control in Power Electronics.

[15]  J L Agorreta,et al.  Modeling and Control of $N$ -Paralleled Grid-Connected Inverters With LCL Filter Coupled Due to Grid Impedance in PV Plants , 2011, IEEE Transactions on Power Electronics.

[16]  Frede Blaabjerg,et al.  An Active Damper for Stabilizing Power-Electronics-Based AC Systems , 2014 .

[17]  Bangyin Liu,et al.  Photovoltaic DC-Building-Module-Based BIPV System—Concept and Design Considerations , 2011, IEEE Transactions on Power Electronics.