Search for optimal tube voltage for image plate radiography

Purpose: To search for the tube voltage which results in the highest clinical image quality per effective dose unit for chest and pelvis radiography respectively, using image plates. Methods: Two anthropomorphic phantoms were imaged with several different tube voltages. For the chest phantom, the tube voltage was varied between 70 and 150 kV, and for the pelvis phantom between 50 and 102 kV. The mAs settings were chosen so that the effective dose to the phantom was the same, regardless of the tube voltage, for the two examinations re-spectively. The clinical image quality of the resulting images was evaluated by a panel of experienced radiologists with vis-ual grading analysis of defined anatomical structures taken from the European Image Criteria. Images produced with the standard tube voltage settings (125 kV for chest and 70 kV for pelvis) were used as reference. These two kV settings were previously used for screen film radiography. Results: For both the chest and the pelvis examinations the image quality at a constant level of effective dose increased when the tube voltage was reduced. Concl usions: The image quality of image plate radiography can be increased by lowering the tube voltage compared to what was used for screen film radiography.

[1]  R. F. Bury,et al.  Towards image quality, beam energy and effective dose optimisation in digital thoracic radiography , 2001, European Radiology.

[2]  S. Kheddache,et al.  In search of optimum chest radiography techniques. , 1993, The British journal of radiology.

[3]  James T. Dobbins Image Quality Metrics for Digital Systems , 2000 .

[4]  Dev P. Chakraborty,et al.  The FROC, AFROC and DROC Variants of the ROC Analysis , 2000 .

[5]  P ? ? ? ? ? ? ? % ? ? ? ? , 1991 .

[6]  M Båth,et al.  The influence of different technique factors on image quality of chest radiographs as evaluated by modified CEC image quality criteria. , 2002, The British journal of radiology.

[7]  G D Gillan,et al.  Development of a radiographic chest phantom with disease simulation. , 1979, Investigative radiology.

[8]  Charles E. Metz Fundamental ROC Analysis , 2000 .

[9]  Patrik Sund,et al.  Evaluation of lumbar spine images with added pathology , 2000, Medical Imaging.

[10]  J A Rowlands,et al.  X-ray detectors for digital radiography. , 1997, Physics in medicine and biology.

[11]  B. Wall,et al.  Estimation of effective dose in diagnostic radiology from entrance surface dose and dose-area product measurements , 1994 .

[12]  S. Mattsson,et al.  Comparison of two methods for evaluating image quality of chest radiographs , 2000, Medical Imaging.

[13]  Patrik Sund,et al.  What is worse: decreased spatial resolution or increased noise? , 2002, SPIE Medical Imaging.

[14]  Anders Tingberg Quantifying the quality of medical x-ray images. An evaluation based on normal anatomy for lumbar spine and chest radiography. , 2000 .

[15]  Lars Gunnar Månsson Evaluation of radiographic procedures : investigations related to chest imaging , 1994 .

[16]  C E Ravin,et al.  Digital chest radiography with photostimulable storage phosphors: signal-to-noise ratio as a function of kilovoltage with matched exposure risk. , 1993, Radiology.

[17]  D R Dance,et al.  A Monte Carlo study of grid performance in diagnostic radiology: task-dependent optimization for digital imaging. , 1994, Physics in medicine and biology.

[18]  C E Ravin,et al.  Threshold perception performance with computed and screen-film radiography: implications for chest radiography. , 1992, Radiology.