Controlled colonic insufflation by a remotely triggered capsule for improved mucosal visualization

BACKGROUND AND STUDY AIMS Capsule endoscopy is an attractive alternative to colorectal cancer screening by conventional colonoscopy, but is currently limited by compromised mucosal visibility because of the lack of safe, controlled colonic insufflation. We have therefore developed a novel system of untethered, wireless-controlled carbon dioxide (CO2) insufflation for use in colonic capsule endoscopy, which this study aims to assess in vivo. MATERIAL AND METHODS This observational, nonsurvival, in vivo study used five Yorkshire-Landrace cross swine. A novel insufflation capsule was placed in the porcine colons, and we recorded volume of insufflation, time, force, visualization, and a pathologic assessment of the colon. RESULTS The mean (standard deviation [SD]) diameter of insufflation was 32.1 (3.9) mm. The volume of CO2 produced successfully allowed complete endoscopic visualization of the mucosa and safe proximal passage of the endoscope. Pathologic examination demonstrated no evidence of trauma caused by the capsule. CONCLUSIONS These results demonstrate the feasibility of a novel method of controlled colonic insufflation via an untethered capsule in vivo. This technological innovation addresses a critical need in colon capsule endoscopy.

[1]  Byron F. Smith,et al.  Novel approach for colonic insufflation via an untethered capsule (with video). , 2013, Gastrointestinal endoscopy.

[2]  P. Bassett,et al.  Dynamic patient position changes during colonoscope withdrawal increase adenoma detection: a randomized, crossover trial. , 2011, Gastrointestinal endoscopy.

[3]  G. Friedman,et al.  A case-control study of screening sigmoidoscopy and mortality from colorectal cancer. , 1992, The New England journal of medicine.

[4]  Antoni Castells,et al.  Low adherence to colonoscopy in the screening of first-degree relatives of patients with colorectal cancer , 2007, Gut.

[5]  N. Shaheen,et al.  The use of carbon dioxide for insufflation during GI endoscopy: a systematic review. , 2009, Gastrointestinal endoscopy.

[6]  C. Hassan,et al.  Literature review and recommendations for clinical application of Colon Capsule Endoscopy. , 2011, Digestive and liver disease : official journal of the Italian Society of Gastroenterology and the Italian Association for the Study of the Liver.

[7]  R. Turnock,et al.  Colonic transit time--what is normal? , 2004, Journal of pediatric surgery.

[8]  Guido Costamagna,et al.  Second-generation colon capsule endoscopy compared with colonoscopy. , 2011, Gastrointestinal endoscopy.

[9]  M. Pennazio Small-bowel endoscopy endoscopy , 2008 .

[10]  Mostafa Ibrahim,et al.  Video capsule endoscopy: what is the future? , 2010, Gastroenterology clinics of North America.

[11]  C. Mulrow,et al.  Colorectal cancer screening: clinical guidelines and rationale. , 1997, Gastroenterology.

[12]  M. Pennazio Small-Bowel Endoscopy , 2000, Endoscopy.

[13]  S. Moss,et al.  Randomised controlled trial of faecal-occult-blood screening for colorectal cancer , 1989, The Lancet.

[14]  M. Tada,et al.  Small-bowel endoscopy. , 1984, Scandinavian journal of gastroenterology. Supplement.

[15]  Robert J. Mayer,et al.  Erratum: Colorectal cancer screening: Clinical guidelines and rationale (Gastroenterology (1997) 112 (594-642)) , 1997 .

[16]  Pietro Valdastri,et al.  Wireless Insufflation of the Gastrointestinal Tract , 2013, IEEE Transactions on Biomedical Engineering.

[17]  Yasser M Bhat,et al.  Methods of luminal distention for colonoscopy. , 2013, Gastrointestinal endoscopy.

[18]  M. Moshkowitz,et al.  A novel device for rapid cleaning of poorly prepared colons. , 2010, Endoscopy.

[19]  J. Olsen,et al.  Randomised study of screening for colorectal cancer with faecal-occult-blood test , 1996, The Lancet.