From twitch to tetanus for human muscle: experimental data and model predictions for m. triceps surae

Abstract. In models describing the excitation of muscle by the central nervous system, it is often assumed that excitation during a tetanic contraction can be obtained by the linear summation of responses to individual stimuli, from which the active state of the muscle is calculated. We investigate here the extent to which such a model describes the excitation of human muscle in vivo. For this purpose, experiments were performed on the calf muscles of four healthy subjects. Values of parameters in the model describing the behaviour of the contractile element (CE) and the series elastic element (SEE) of this muscle group were derived on the basis of a set of isokinetic release contractions performed on a special-purpose dynamometer as well as on the basis of morphological data. Parameter values describing the excitation of the calf muscles were optimized such that the model correctly predicted plantar flexion moment histories in an isometric twitch, elicited by stimulation of the tibial nerve. For all subjects, the model using these muscle parameters was able to make reasonable predictions of isometric moment histories at higher stimulation frequencies. These results suggest that the linear summation of responses to individual stimuli can indeed give an adequate description of the process of human muscle excitation in vivo.

[1]  A V HILL The series elastic component of muscle. , 1950, Proceedings of the Royal Society of London. Series B, Biological sciences.

[2]  Maarten F. Bobbert,et al.  From twitch to tetanus: performance of excitation dynamics optimized for a twitch in predicting tetanic muscle forces , 1996, Biological Cybernetics.

[3]  T. Brubaker,et al.  Nonlinear Parameter Estimation , 1979 .

[4]  L. Shampine,et al.  Computer solution of ordinary differential equations : the initial value problem , 1975 .

[5]  S. R. Taylor,et al.  Calcium transients in amphibian muscle. , 1975, Federation proceedings.

[6]  W S Levine,et al.  An optimal control model for maximum-height human jumping. , 1990, Journal of biomechanics.

[7]  Maarten F. Bobbert,et al.  How to obtain CE force velocity and SEE force -extension relationships from isokinetic releases , 1997 .

[8]  M. Pandy,et al.  Optimal muscular coordination strategies for jumping. , 1991, Journal of biomechanics.

[9]  S. Ebashi,et al.  Calcium ion and muscle contraction. , 1968, Progress in biophysics and molecular biology.

[10]  J. Desmedt,et al.  Kinetics of Myofilament Activation in Potentiated Contraction: Staircase Phenomenon in Human Skeletal Muscle , 1968, Nature.

[11]  J. van den Berg,et al.  EMG to force processing II: Estimation of parameters of the Hill muscle model for the human triceps surae by means of a calfergometer. , 1981, Journal of biomechanics.

[12]  J. Quintern,et al.  Physiologically Based Multi-Input Model of Muscle Activation , 1996 .

[13]  Maarten F. Bobbert,et al.  Evaluation of a self-consistent method for calculating muscle parameters from a set of isokinetic releases , 1997, Biological Cybernetics.

[14]  J. Quintern,et al.  A physiologically based model of muscle activation verified by electrical stimulation , 1997 .

[15]  S. Walker,et al.  I segment lengths and thin filament periods in skeletal muscle fibers of the rhesus monkey and the human , 1974, The Anatomical record.

[16]  A L Hof Correcting for limb inertia and compliance in fast ergometers. , 1997, Journal of biomechanics.

[17]  F.E. Zajac,et al.  Paraplegic standing controlled by functional neuromuscular stimulation. I. Computer model and control-system design , 1989, IEEE Transactions on Biomedical Engineering.

[18]  A L Hof A controlled-release ergometer for the human ankle. , 1997, Journal of biomechanics.

[19]  Maarten F. Bobbert,et al.  Dependence of human maximum jump height on moment arms of the bi-articular m. gastrocnemius; a simulation study , 1994 .

[20]  P Klein,et al.  Moment arm length variations of selected muscles acting on talocrural and subtalar joints during movement: an in vitro study. , 1996, Journal of biomechanics.

[21]  A. Prochazka,et al.  The bionic glove: an electrical stimulator garment that provides controlled grasp and hand opening in quadriplegia. , 1997, Archives of physical medicine and rehabilitation.