Particle size distributions and compositions of aerosols produced by near-IR femto- and nanosecond laser ablation of brass

Particle size distributions and compositions of primary aerosols produced by means of near-IR femtosecond laser ablation (λ = 775 nm) of brass in He or Ar at atmospheric pressure have been measured. Aerosols were characterized using a 13-stage low-pressure impactor covering a size range from 5 nm up to 5 μm and subsequently analyzed applying total reflection X-ray fluorescence spectrometry. The results indicate, that for femtosecond laser ablation in the low-fluence regime (<5 J cm−2) ultra-fine aerosols (mean diameter dp ≈ 10 nm/peak width wp ≈ 35 nm) are produced. Furthermore, the total Cu/Zn ratio of these aerosols corresponds to the composition of the bulk material. In contrast, ablation above 10 J cm−2 results in the formation of polydisperse, bimodal aerosols, which are distributed around dp1 ≈ 20 nm (wp1 ≈ 50 nm) and dp2 ≈ 1 μm (wp2 ≈ 5 µm), respectively, and whose total Cu/Zn ratio slightly deviates from the bulk composition. In order to examine the influence of pulse duration on particle size distribution and aerosol composition, comparative measurements by means of near-IR nanosecond ablation were also performed. The data show that nanosecond ablation generally leads to an intensified formation of particles in the micrometer range. Moreover, the composition of these aerosols strongly departs from the stoichiometry of the bulk. Aspects concerning the formation of particles during ablation as well as implications for the element-selective analysis by inductively coupled plasma spectrometry are discussed.

[1]  Steven Frederick Durrant,et al.  Laser ablation inductively coupled plasma mass spectrometry: achievements, problems, prospects , 1999 .

[2]  N. Arnold,et al.  Spherical expansion of the vapor plume into ambient gas: an analytical model , 1999 .

[3]  D. Günther,et al.  Elemental fractionation studies in laser ablation inductively coupled plasma mass spectrometry on laser-induced brass aerosols. , 2003, Analytical chemistry.

[4]  H. Stephanowitz,et al.  Collection and separation of particles by size from laser ablated material , 2002 .

[5]  D. Günther,et al.  Effect of particle size distribution on ICP-induced elemental fractionation in laser ablation-inductively coupled plasma-mass spectrometry , 2002 .

[6]  K. Niemax Laser ablation – reflections on a very complex technique for solid sampling , 2001, Fresenius' journal of analytical chemistry.

[7]  M. Chaker,et al.  Critical-point phase separation in laser ablation of conductors. , 2001, Physical review letters.

[8]  J. Becker,et al.  A new strategy of solution calibration in laser ablation inductively coupled plasma mass spectrometry for multielement trace analysis of geological samples , 2000, Fresenius' journal of analytical chemistry.

[9]  Xianglei Mao,et al.  Laser ablation in analytical chemistry-a review. , 2002, Talanta.

[10]  D. Grégoire,et al.  The formation of trace element-enriched particulates during laser ablation of refractory materials , 1996 .

[11]  S. I. Anisimov,et al.  Condensation of Vapor and Nanoclusters Formation within the Vapor Plume, Produced by ns-Laser Ablation of Si , 2003 .

[12]  A. Bohlen,et al.  Total reflection X-ray fluorescence—an efficient method for micro-, trace and surface layer analysis. Invited lecture , 1992 .

[13]  R. Russo,et al.  Optimization and Calibration of Laser Ablation–InductivelyCoupled Plasma Atomic Emission Spectrometry by Measuring Vertical SpatialIntensity Profiles , 1997 .

[14]  K. Niemax,et al.  Elemental composition of laser ablation aerosol particles deposited in the transport tube to an ICP , 2002 .

[15]  Xianglei Mao,et al.  Femtosecond laser ablation ICP-MS , 2002 .

[16]  D. Günther,et al.  Elemental fractionation in laser ablation inductively coupled plasma mass spectrometry , 1996, Analytical and bioanalytical chemistry.