Single-shot line scan imaging using stimulated echoes.

A new high-speed MRI method is described for single-shot line scan imaging (LSI) based on stimulated echoes (STE). To allow for multislice imaging, the technique comprises a series of slice-selective preparation pulses (each corresponding to the first RF pulse of a STE sequence), a slab-selective refocusing pulse (second RF pulse), and multiple line-selective read pulses (third RF pulses). An alternative version employs packages of two slice-selective pulses followed by multiple line-selective read pulses. Experimental applications deal with human brain imaging on a clinical MRI system at 2.0 T. The technique offers user-selectable trade-offs between volume coverage (1-15 sections) and in-plane spatial resolution (1-5 mm linear pixel dimension) within total acquisition times of less than 500 ms. Although LSI yields a lower signal-to-noise ratio than Fourier imaging, single-shot LSI with STEs is free from resonance offset effects (e.g., magnetic field inhomogeneities and susceptibility differences) that are typical for echo-planar imaging. Moreover, the technique exhibits considerable robustness against motion and provides access to arbitrary fields-of-view, i.e., localized imaging of inner volumes without aliasing artifacts due to phase wrapping.

[1]  P. Mansfield,et al.  Medical imaging by NMR. , 1977, The British journal of radiology.

[2]  P G Morris,et al.  Human whole body line-scan imaging by NMR. , 1978, The British journal of radiology.

[3]  Andrew A. Maudsley,et al.  Multiple-line-scanning spin density imaging , 1980 .

[4]  W. Edelstein,et al.  Spin warp NMR imaging and applications to human whole-body imaging. , 1980, Physics in medicine and biology.

[5]  L. Crooks Selective Irradiation Line Scan Techniques for NMR Imaging , 1980 .

[6]  Jens Frahm,et al.  Rapid NMR imaging using stimulated echoes , 1985 .

[7]  J Hennig,et al.  RARE imaging: A fast imaging method for clinical MR , 1986, Magnetic resonance in medicine.

[8]  Robert Turner,et al.  Diffusion and perfusion magnetic resonance imaging , 1992 .

[9]  A time encoding method for single‐shot imaging , 1995, Magnetic resonance in medicine.

[10]  Jonathan S. Lewin,et al.  Diffusion and Perfusion Magnetic Resonance Imaging , 1996, Neurology.

[11]  F A Jolesz,et al.  Double line scan diffusion imaging , 1997, Magnetic resonance in medicine.

[12]  A Briguet,et al.  STEAM‐Burst: A single‐shot, multi‐slice imaging sequence without rapid gradient switching , 1997, Magnetic resonance in medicine.