Detection of coronary calcifications from computed tomography scans for automated risk assessment of coronary artery disease.

A fully automated method for coronary calcification detection from non-contrast-enhanced, ECG-gated multi-slice computed tomography (CT) data is presented. Candidates for coronary calcifications are extracted by thresholding and component labeling. These candidates include coronary calcifications, calcifications in the aorta and in the heart, and other high-density structures such as noise and bone. A dedicated set of 64 features is calculated for each candidate object. They characterize the object's spatial position relative to the heart and the aorta, for which an automatic segmentation scheme was developed, its size and shape, and its appearance, which is described by a set of approximated Gaussian derivatives for which an efficient computational scheme is presented. Three classification strategies were designed. The first one tested direct classification without feature selection. The second approach also utilized direct classification, but with feature selection. Finally, the third scheme employed two-stage classification. In a computationally inexpensive first stage, the most easily recognizable false positives were discarded. The second stage discriminated between more difficult to separate coronary calcium and other candidates. Performance of linear, quadratic, nearest neighbor, and support vector machine classifiers was compared. The method was tested on 76 scans containing 275 calcifications in the coronary arteries and 335 calcifications in the heart and aorta. The best performance was obtained employing a two-stage classification system with a k-nearest neighbor (k-NN) classifier and a feature selection scheme. The method detected 73.8% of coronary calcifications at the expense of on average 0.1 false positives per scan. A calcium score was computed for each scan and subjects were assigned one of four risk categories based on this score. The method assigned the correct risk category to 93.4% of all scans.

[1]  Anil K. Jain,et al.  Statistical Pattern Recognition: A Review , 2000, IEEE Trans. Pattern Anal. Mach. Intell..

[2]  R. Detrano,et al.  Quantification of coronary artery calcium using ultrafast computed tomography. , 1990, Journal of the American College of Cardiology.

[3]  D. Rader,et al.  Electron beam computed tomographic coronary calcium scanning: a review and guidelines for use in asymptomatic persons. , 1999, Mayo Clinic proceedings.

[4]  T. Callister,et al.  Coronary artery disease: improved reproducibility of calcium scoring with an electron-beam CT volumetric method. , 1998, Radiology.

[5]  Sabee Molloi,et al.  Feasibility of real time dual-energy imaging based on a flat panel detector for coronary artery calcium quantification. , 2006, Medical physics.

[6]  R. Detrano,et al.  Calcified coronary artery plaque measurement with cardiac CT in population-based studies: standardized protocol of Multi-Ethnic Study of Atherosclerosis (MESA) and Coronary Artery Risk Development in Young Adults (CARDIA) study. , 2005, Radiology.

[7]  B. van Ginneken,et al.  Automated coronary calcification detection and scoring , 2005, ISPA 2005. Proceedings of the 4th International Symposium on Image and Signal Processing and Analysis, 2005..

[8]  M. Leon,et al.  Patterns of calcification in coronary artery disease. A statistical analysis of intravascular ultrasound and coronary angiography in 1155 lesions. , 1995, Circulation.

[9]  C. Becker,et al.  Reproducibility of coronary calcium quantification in repeat examinations with retrospectively ECG-gated multisection spiral CT , 2002, European Radiology.

[10]  Ivana Išgum,et al.  A pattern recognition approach to automated coronary calcium scoring , 2004, ICPR 2004.

[11]  Anil K. Jain,et al.  Feature Selection: Evaluation, Application, and Small Sample Performance , 1997, IEEE Trans. Pattern Anal. Mach. Intell..

[12]  S. Blair,et al.  Coronary artery calcium score and coronary heart disease events in a large cohort of asymptomatic men and women. , 2005, American journal of epidemiology.

[13]  W. Janowitz,et al.  Ultrafast computed tomography-detected coronary calcium reflects the angiographic extent of coronary arterial atherosclerosis. , 1994, The American journal of cardiology.

[14]  Paul A. Viola,et al.  Detecting Pedestrians Using Patterns of Motion and Appearance , 2005, International Journal of Computer Vision.

[15]  Paul A. Viola,et al.  Rapid object detection using a boosted cascade of simple features , 2001, Proceedings of the 2001 IEEE Computer Society Conference on Computer Vision and Pattern Recognition. CVPR 2001.

[16]  V. Fuster,et al.  Computed Tomography and Magnetic Resonance Imaging for Noninvasive Coronary Angiography and Plaque Imaging: Current and Potential Future Concepts , 2002, Circulation.

[17]  Y. Arad,et al.  Objectives Background Methods Results Conclusions , 2022 .

[18]  Michael Motro,et al.  Coronary artery calcium measurement with multi-detector row CT and low radiation dose: comparison between 55 and 165 mAs. , 2005, Radiology.

[19]  Kiang Liu,et al.  Electron-Beam Tomography Coronary Artery Calcium and Cardiac Events: A 37-Month Follow-Up of 5635 Initially Asymptomatic Low- to Intermediate-Risk Adults , 2003, Circulation.

[20]  Michael McNitt-Gray,et al.  Coronary calcium measurements: effect of CT scanner type and calcium measure on rescan reproducibility--MESA study. , 2005, Radiology.

[21]  Timothy F. Cootes,et al.  Active Shape Models-Their Training and Application , 1995, Comput. Vis. Image Underst..

[22]  R. Detrano,et al.  Coronary artery calcium score combined with Framingham score for risk prediction in asymptomatic individuals. , 2004, JAMA.