Fault-tolerant strategy using neutral-shift method for cascaded multilevel inverters based on level-shifted PWM

Most proposed methods for a fault-tolerant operation in many of studies are based on a phase-shifted PWM (PS-PWM) method. However these methods are not applied directly to multilevel inverter systems using a level-shifted PWM (LS-PWM). This paper focuses on fault-tolerant operation for a cascaded multilevel inverter based on LS-PWM. During the occurrence of a single-inverter-cell fault, reconfiguration of the carrier bands scheme is implemented and modulation assignment of inverter cells is modified in this proposed fault-tolerant operation. It is possible to generate balanced three-phase line-to-line voltages and line currents with the proposed strategy when a device failure occurs in cascaded multilevel inverters using LS-PWM. The feasibility of the proposed method is proved by simulation results.

[1]  June-Seok Lee,et al.  Cascaded H-bridge multilevel inverter for increasing output voltage levels , 2014, 2014 IEEE Conference on Energy Conversion (CENCON).

[2]  Bin Wu,et al.  High-Power Converters and ac Drives: Wu/High-Power Converters and ac Drives , 2006 .

[3]  Alex Q. Huang,et al.  Control Strategy for Fault-Tolerant Cascaded Multilevel Converter based STATCOM , 2007, APEC 07 - Twenty-Second Annual IEEE Applied Power Electronics Conference and Exposition.

[4]  June-Seok Lee,et al.  A detection method for an open-switch fault in cascaded H-bridge multilevel inverters , 2014, 2014 IEEE Energy Conversion Congress and Exposition (ECCE).

[5]  Hirofumi Akagi,et al.  Fault-Tolerant Operation of a Battery-Energy-Storage System Based on a Multilevel Cascade PWM Converter With Star Configuration , 2010, IEEE Transactions on Power Electronics.

[6]  Ahmed Hammoda,et al.  Evaluation of modulation techniques for 5-level inverter based on multicarrier level shift PWM , 2014, MELECON 2014 - 2014 17th IEEE Mediterranean Electrotechnical Conference.

[7]  Bin Wu,et al.  Control method for cascaded H-bridge multilevel inverter with faulty power cells , 2003, Eighteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2003. APEC '03..

[8]  Lei Hu,et al.  Reconfiguration of Carrier-Based Modulation Strategy for Fault Tolerant Multilevel Inverters , 2007, IEEE Transactions on Power Electronics.

[9]  Pablo Lezana,et al.  Operation of a medium-voltage drive under faulty conditions , 2004, IEEE Transactions on Industrial Electronics.

[10]  Mariusz Malinowski,et al.  A Survey on Cascaded Multilevel Inverters , 2010, IEEE Transactions on Industrial Electronics.

[11]  L.M. Tolbert,et al.  Fault Detection and Reconfiguration Technique for Cascaded H-bridge 11-level Inverter Drives Operating under Faulty Condition , 2007, 2007 7th International Conference on Power Electronics and Drive Systems.

[12]  Ji-Yoon Yoo,et al.  Unbalanced three-phase control using offset-voltage for H-bridge multilevel inverter with faulty power cells , 2008, 2008 IEEE Power Electronics Specialists Conference.

[13]  P. Hammond,et al.  Neutral shift [five years of continuous operation with adjustable frequency drives] , 2003 .

[14]  Brendan Peter McGrath,et al.  Multicarrier PWM strategies for multilevel inverters , 2002, IEEE Trans. Ind. Electron..

[15]  Bin Wu,et al.  Multilevel Voltage-Source-Converter Topologies for Industrial Medium-Voltage Drives , 2007, IEEE Transactions on Industrial Electronics.