Quality of nonmydriatic digital fundus photography obtained by nurse practitioners in the emergency department: the FOTO-ED study.

OBJECTIVE Nonmydriatic fundus photography by non-ophthalmic-trained personnel has recently been shown to be a potential alternative to direct ophthalmoscopy in the emergency department (ED). We evaluated the reliability of a novel quality rating scale and applied this scale to nonmydriatic fundus photographs taken during routine ED patient encounters to determine factors associated with diminished photograph quality. DESIGN Prospective, cross-sectional study. PARTICIPANTS We included 350 patients enrolled in the Fundus photography versus Ophthalmoscopy Trials Outcomes in the Emergency Department study who were photographed by nurse practitioners after <30 minutes of training followed by supervision. METHODS Photographs of both eyes were graded for quality on 2 occasions by 2 neuro-ophthalmologists. Four regions were independently evaluated for quality: Optic disc, macula, and superior and inferior vascular arcades. Quality as a function of the number of photographs taken was evaluated by Kaplan-Meier analysis. Mixed effects ordinal logistic regression was used to evaluate for predictors of image quality while accounting for the repeated measures design. MAIN OUTCOME MEASURES Overall photographic quality (1-5 scale; 5 best). RESULTS We evaluated 1734 photographs. Inter- and intraobserver agreements between neuro-ophthalmologists were very good (weighted kappa, 0.84-0.87). Quality of the optic disc area was better than those of other retinal areas (P<0.002). Kaplan-Meier analysis showed that if a high-quality photograph of an eye was not obtained by the third attempt, it was unlikely that one would be obtained at all. A 10-second increase in the interphotograph interval before a total of 40 seconds increased the odds of a 1-unit higher quality rating by 1.81 times (95% confidence interval [CI], 1.68-1.98), and a 10-year increase in age decreased the odds by 0.76 times (95% CI, 0.69-0.85). Black patients had 0.42 times (95% CI, 0.28-0.63) the odds of a 1-unit higher quality rating compared with whites. CONCLUSIONS Our 5-point scale is a reliable measure of nonmydriatic photograph quality. The region of interest, interphotograph interval, and patient age and race are significant predictors of image quality for nonmydriatic photographs taken by nurse practitioners in the ED. Addressing these factors may have a direct impact on the successful implementation of nonmydriatic fundus photography into the ED.

[1]  F. Delori,et al.  Spectral reflectance of the human ocular fundus. , 1989, Applied optics.

[2]  Valérie Biousse,et al.  Nonmydriatic ocular fundus photography in the emergency department. , 2011, The New England journal of medicine.

[3]  R. Klein,et al.  Detection of age-related macular degeneration using a nonmydriatic digital camera and a standard film fundus camera. , 2004, Archives of ophthalmology.

[4]  J. Lim,et al.  A comparison of digital nonmydriatic fundus imaging with standard 35-millimeter slides for diabetic retinopathy. , 2000, Ophthalmology.

[5]  C. Walton,et al.  A national survey of the current state of screening services for diabetic retinopathy: ABCD–Diabetes UK survey of specialist diabetes services 2006 , 2009, Diabetic medicine : a journal of the British Diabetic Association.

[6]  Family Practices' Achievement of Diabetes Quality of Care Targets and Risk of Screen-Detected Diabetic Retinopathy , 2010, PloS one.

[7]  S. Jain,et al.  Screening for age-related macular degeneration using nonstereo digital fundus photographs , 2006, Eye.

[8]  I. Constable,et al.  Diabetic screening in Western Australia: A photographer’s perspective , 2006, Journal of visual communication in medicine.

[9]  L. Aiello,et al.  Stereo nonmydriatic digital-video color retinal imaging compared with Early Treatment Diabetic Retinopathy Study seven standard field 35-mm stereo color photos for determining level of diabetic retinopathy. , 2001, Ophthalmology.

[10]  P. Massin,et al.  Evaluation of a new non‐mydriatic digital camera for detection of diabetic retinopathy , 2003, Diabetic medicine : a journal of the British Diabetic Association.

[11]  David W Wright,et al.  Feasibility of nonmydriatic ocular fundus photography in the emergency department: Phase I of the FOTO-ED study. , 2011, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[12]  G. Leese,et al.  Use of mobile screening unit for diabetic retinopathy in rural and urban areas. , 1993, BMJ.

[13]  K. Alberti,et al.  Comparison of non-mydriatic retinal photography with ophthalmoscopy in 2159 patients: mobile retinal camera study. , 1990, BMJ.

[14]  D. Owens,et al.  Non-mydriatic Polaroid photography in screening for diabetic retinopathy: evaluation in a clinical setting , 1988, British medical journal.

[15]  M. Tyrberg,et al.  Colour slides or digital photography in diabetes screening--a comparison. , 2000, Acta ophthalmologica Scandinavica.

[16]  R. Klein,et al.  Diabetic retinopathy as detected using ophthalmoscopy, a nonmydriatic camera and a standard fundus camera. , 1985, Ophthalmology.

[17]  E. Souied,et al.  Interobserver and intraobserver reliability of detecting age-related macular degeneration using a nonmydriatic digital camera. , 2008, American journal of ophthalmology.

[18]  P. Scanlon,et al.  The effectiveness of screening for diabetic retinopathy by digital imaging photography and technician ophthalmoscopy , 2003, Diabetic medicine : a journal of the British Diabetic Association.

[19]  Emily Y Chew,et al.  Screening options for diabetic retinopathy. , 2006, Current opinion in ophthalmology.

[20]  S. Nussey,et al.  Assessment of non-mydriatic fundus photography in detection of diabetic retinopathy. , 1986, British medical journal.

[21]  J. Ellis,et al.  Effect of mydriasis and different field strategies on digital image screening of diabetic eye disease , 2004, British Journal of Ophthalmology.

[22]  A. Erginay,et al.  OPHDIAT: a telemedical network screening system for diabetic retinopathy in the Ile-de-France. , 2008, Diabetes & metabolism.