Monte Carlo calculations of the absorbed dose and energy dependence of plastic scintillators.

Detector systems using plastic scintillators can provide instantaneous measurements with high spatial resolution in many applications including small field and high dose gradient field applications. Energy independence and water equivalence are important dosimetric properties that determine whether a detector will be useful in a clinical setting. Using Monte Carlo simulations, we calculated the energy dependence of plastic scintillators when exposed to photon beams in the radiotherapeutic range. These calculations were performed for a detector comprised of a BC-400 plastic scintillator surrounded by a polystyrene wall. Our results showed the plastic scintillation detector to be nearly energy independent over a range of energies from 0.5 to 20 MeV. The ratio of the dose absorbed by the scintillator to that absorbed by water was nearly a constant, approximately equal to 0.98 over the entire energy range of interest. These results confirm the water equivalence of the plastic scintillation detector and are in very good agreement with earlier results obtained using Burlin cavity theory.

[1]  Natalka Suchowerska,et al.  Plastic scintillation dosimetry: optimization of light collection efficiency. , 2003, Physics in medicine and biology.

[2]  P N Johnston,et al.  A temporal method of avoiding the Cerenkov radiation generated in organic scintillator dosimeters by pulsed mega-voltage electron and photon beams. , 2002, Physics in medicine and biology.

[3]  J. W. Epstein,et al.  Towards two-dimensional brachytherapy dosimetry using plastic scintillator: new highly efficient water equivalent plastic scintillator materials. , 1999, Medical physics.

[4]  J. M. Fontbonne,et al.  Scintillating fiber dosimeter for radiation therapy accelerator , 2001 .

[5]  J. Halbleib,et al.  Structure and Operation of the ITS Code System , 1988 .

[6]  F. H. Attix,et al.  Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements. , 1992, Physics in medicine and biology.

[7]  D. Sheikh-Bagheri,et al.  Sensitivity of megavoltage photon beam Monte Carlo simulations to electron beam and other parameters. , 2002, Medical physics.

[8]  C. Sibata,et al.  A miniature "scintillator-fiberoptic-PMT" detector system for the dosimetry of small fields in stereotactic radiosurgery , 2001 .

[9]  J. Pouliot,et al.  Miniature scintillating detector for small field radiation therapy. , 1999, Medical physics.

[10]  F. H. Attix,et al.  Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical consideration. , 1992, Physics in medicine and biology.

[11]  T. E. Burlin A general theory of cavity ionisation. , 1966, The British journal of radiology.

[12]  R. Mohan,et al.  Determining the incident electron fluence for Monte Carlo-based photon treatment planning using a standard measured data set. , 2003, Medical physics.

[13]  C. Ma,et al.  BEAM: a Monte Carlo code to simulate radiotherapy treatment units. , 1995, Medical physics.

[14]  S. Seltzer,et al.  Dosimetry characterization of 32P catheter-based vascular brachytherapy source wire. , 2000, Medical physics.

[15]  Yves Charon,et al.  SIC, an intracerebral radiosensitive probe for in vivo neuropharmacology investigations in small laboratory animals: theoretical considerations and practical characteristics , 2000 .

[16]  R A Sutton,et al.  Water equivalence of plastic organic scintillators in megavoltage radiotherapy bremsstrahlung beams. , 2000, Physics in medicine and biology.

[17]  Firas Mourtada,et al.  Dosimetry characterization of a 32P source wire used for intravascular brachytherapy with automated stepping. , 2003, Medical physics.

[18]  F. Mourtada,et al.  Dosimetry of beta-ray ophthalmic applicators: comparison of different measurement methods. , 2001, Medical physics.

[19]  A. Beddar A new scintillator detector system for the quality assurance of 60Co and high-energy therapy machines. , 1994, Physics in medicine and biology.

[20]  D Flühs,et al.  Direct reading measurement of absorbed dose with plastic scintillators--the general concept and applications to ophthalmic plaque dosimetry. , 1996, Medical physics.

[21]  R. Mohan,et al.  Reference photon dosimetry data and reference phase space data for the 6 MV photon beam from varian clinac 2100 series linear accelerators. , 2004, Medical physics.

[22]  Philippe Hantraye,et al.  In vivo quantification of localized neuronal activation and inhibition in the rat brain using a dedicated high temporal-resolution β+-sensitive microprobe , 2002, Proceedings of the National Academy of Sciences of the United States of America.

[23]  J. Dempsey,et al.  Plastic scintillator response to low-energy photons. , 1999, Physics in medicine and biology.

[24]  Natalka Suchowerska,et al.  Plastic scintillation dosimetry for radiation therapy: minimizing capture of Cerenkov radiation noise. , 2004, Physics in medicine and biology.