CT image quality improvement using adaptive iterative dose reduction with wide-volume acquisition on 320-detector CT

ObjectivesTo evaluate the impact of Adaptive Iterative Dose Reduction (AIDR) on image quality and radiation dose in phantom and patient studies.MethodsA phantom was examined in volumetric mode on a 320-detector CT at different tube currents from 25 to 550 mAs. CT images were reconstructed with AIDR and with Filtered Back Projection (FBP) reconstruction algorithm. Image noise, Contrast-to-Noise Ratio (CNR), Signal-to-Noise Ratio (SNR) and spatial resolution were compared between FBP and AIDR images. AIDR was then tested on 15 CT examinations of the lumbar spine in a prospective study. Again, FBP and AIDR images were compared. Image noise and SNR were analysed using a Wilcoxon signed-rank test.ResultsIn the phantom, spatial resolution assessment showed no significant difference between FBP and AIDR reconstructions. Image noise was lower with AIDR than with FBP images with a mean reduction of 40%. CNR and SNR were also improved with AIDR. In patients, quantitative and subjective evaluation showed that image noise was significantly lower with AIDR than with FBP. SNR was also greater with AIDR than with FBP.ConclusionCompared to traditional FBP reconstruction techniques, AIDR significantly improves image quality and has the potential to decrease radiation dose.Key PointsThis study showed that Adaptive Iterative Dose Reduction (AIDR) reduces image noise.In a phantom image noise was reduced without altering spatial resolution.In patients AIDR reduced the image noise in lumbar spine CT.AIDR can potentially reduce the dose for lumbar spine CT by 52%.

[1]  M F McNitt-Gray,et al.  Application of the noise power spectrum in modern diagnostic MDCT: part II. Noise power spectra and signal to noise , 2007, Physics in medicine and biology.

[2]  Harlan M Krumholz,et al.  Exposure to low-dose ionizing radiation from medical imaging procedures. , 2009, The New England journal of medicine.

[3]  Jean-Baptiste Thibault,et al.  A three-dimensional statistical approach to improved image quality for multislice helical CT. , 2007, Medical physics.

[4]  A. Blum,et al.  Réduction de dose dans l’exploration du rachis lombaire grâce au scanner 320-détecteurs : étude initiale , 2010 .

[5]  Jingyan Xu,et al.  Is iterative reconstruction ready for MDCT? , 2009, Journal of the American College of Radiology : JACR.

[6]  L. Tanoue Computed Tomography — An Increasing Source of Radiation Exposure , 2009 .

[7]  E. Spangfort,et al.  The lumbar disc herniation. A computer-aided analysis of 2,504 operations. , 1972, Acta orthopaedica Scandinavica. Supplementum.

[8]  P. Gevenois,et al.  Multidetector CT in patients suspected of having lumbar disk herniation: comparison of standard-dose and simulated low-dose techniques. , 2007, Radiology.

[9]  B. Tins Technical aspects of CT imaging of the spine , 2010, Insights into imaging.

[10]  H. M. Krumholz,et al.  Exposure to Low-Dose Ionizing Radiation from Medical Imaging Procedures , 2009 .

[11]  F. Guillemin,et al.  [Dose reduction at CT of the lumbar spine using a 320-detector row scanner: initial results]. , 2010, Journal de radiologie.

[12]  K. P. Kim,et al.  Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer. , 2009, Archives of internal medicine.

[13]  J. Remy,et al.  Chest computed tomography using iterative reconstruction vs filtered back projection (Part 2): image quality of low-dose CT examinations in 80 patients , 2011, European Radiology.

[14]  Willi A Kalender,et al.  Technical approaches to the optimisation of CT. , 2008, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[15]  A. Sodickson,et al.  Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risks from CT of adults. , 2009, Radiology.

[16]  H. Alkadhi,et al.  Radiation dose of cardiac computed tomography – what has been achieved and what needs to be done , 2011, European Radiology.

[17]  Rebecca S Lewis,et al.  Projected cancer risks from computed tomographic scans performed in the United States in 2007. , 2009, Archives of internal medicine.

[18]  M. Galanski,et al.  Informatics in radiology: sliding-thin-slab averaging for improved depiction of low-contrast lesions with radiation dose savings at thin-section CT. , 2010, Radiographics : a review publication of the Radiological Society of North America, Inc.

[19]  G Allan Johnson,et al.  Optimization of eight-element multi-detector row helical CT technology for evaluation of the abdomen. , 2003, Radiology.

[20]  Jiang Hsieh,et al.  Diffuse lung disease: CT of the chest with adaptive statistical iterative reconstruction technique. , 2010, Radiology.

[21]  C. McCollough,et al.  Dose reduction in helical CT: dynamically adjustable z-axis X-ray beam collimation. , 2010, AJR. American journal of roentgenology.

[22]  William P. Shuman,et al.  Adaptive statistical iterative reconstruction versus filtered back projection in the same patient: 64 channel liver CT image quality and patient radiation dose , 2011, European Radiology.

[23]  J. Remy,et al.  Chest computed tomography using iterative reconstruction vs filtered back projection (Part 1): evaluation of image noise reduction in 32 patients , 2011, European Radiology.

[24]  Rebecca S Lewis,et al.  Projected cancer risks from computed tomographic scans performed in the United States in 2007. , 2009, Archives of internal medicine.

[25]  Alvin C. Silva,et al.  Iterative Reconstruction Technique for Reducing Body Radiation Dose at Ct: Feasibility Study Hara Et Al. Ct Iterative Reconstruction Technique Gastrointestinal Imaging Original Research , 2022 .

[26]  T. Mulkens,et al.  Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: clinical evaluation. , 2005, Radiology.

[27]  Alvin C. Silva,et al.  Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm. , 2010, AJR. American journal of roentgenology.

[28]  C Ghetti,et al.  CT iterative reconstruction in image space: a phantom study. , 2012, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.