Computer-assisted optimization of an immobilized-enzyme flow-injection system for the determination of glucose

Abstract A flow-injection system utilizing the Trinder reaction for the determination of glucose is designed and optimized. Glucose is converted to gluconic acid by passing it through a single-bead-string reactor (SBSR) onto which glucose oxidase enzyme has been immobilized. As it flows through a second SBSR, the gluconic acid reacts with a reagent stream of horseradish peroxidase, 4-aminoantipyrine and 3,5-dichloro-2-hydroxyphenyl sulfonate. The absorbance of the quinoneimine dye produced is then monitored at 510 nm in a flow-through cell. Optimum operating conditions were sought by using both univariate and Composite Modified Simplex procedures. Seven variables were considered. The performance of the system was improved by a factor of 22.5 relative to the starting conditions. A calibration curve obtainedat the optimum conditions was linear for 0–3.3 mM glucose and usable for 0–5.5 mM glucose. The optimization procedures revealed some interesting aspects of the Trinder reaction. scatter diagrams generated from the simplex data showed definite trends for each of the seven variables. These are discussed.

[1]  P. Rao,et al.  Determination of isonicotinic acid hydrazide in pharmaceutical preparations. , 1973, Analytica Chimica Acta.

[2]  F. E. Semersky,et al.  Development of a glucose analyzer based on immobilized glucose oxidase , 1979 .

[3]  A. Townshend,et al.  Determination of glucose in blood by flow injection analysis and an immobilized glucose oxidase column , 1985 .

[4]  H. Mottola Enzymatic preparations in analytical continuous-flow systems , 1983 .

[5]  L. Gorton,et al.  Flow injection analysis for glucose and urea with enzyme reactors and on-line dialysis , 1981 .

[6]  H. Poppe,et al.  Dispersion in open tubes and tubes packed with large glass beads , 1981 .

[7]  Paul J. Worsfold,et al.  The bio-analytical potential of flow injection analysis , 1983 .

[8]  R. Bovara,et al.  High performance enzyme reactors. , 1976, Biotechnology and bioengineering.

[9]  P. Trinder,et al.  An improved colour reagent for the determination of blood glucose by the oxidase system. , 1972, The Analyst.

[10]  S. Deming,et al.  Teaching the fundamentals of experimental design , 1983 .

[11]  P. Trinder Determination of Glucose in Blood Using Glucose Oxidase with an Alternative Oxygen Acceptor , 1969 .

[12]  D. Burns,et al.  The determination of glucose with immobilized glucose oxidase and peroxidase. , 1977, Analytica chimica acta.

[13]  S. Deming,et al.  Simplex optimization of analytical chemical methods , 1974 .

[14]  Adrian P. Wade,et al.  Computer-assisted optimization for flow injection analysis of isoprenaline , 1983 .

[15]  D. Betteridge,et al.  Reflections on the modified simplex-I. , 1985, Talanta.

[16]  G. Johansson,et al.  An enzymatic flow injection method for the determination of oxygen , 1983 .

[17]  S. R. Crouch,et al.  Experimental comparison of flow-injection analysis and air-segmented continuous flow analysis , 1986 .

[18]  J. Lott,et al.  Evaluation of Trinder's glucose oxidase method for measuring glucose in serum and urine. , 1975, Clinical chemistry.

[19]  D. Keilin,et al.  Properties of glucose oxidase (notatin): Addendum. Sedimentation and diffusion of glucose oxidase (notatin). , 1948, The Biochemical journal.

[20]  Masayoshi Tabata,et al.  Highly sensitive flow injection analysis of glucose and uric acid in serum using an immobilized enzyme column and chemiluminescence. , 1984, Journal of applied biochemistry.

[21]  M. Toriyama,et al.  The Flow-injection Analysis of D-Glucose Using a Flow-cell with Immobilized Peroxidase and Its Application to Serum , 1982 .

[22]  M. Weibel,et al.  Immobilized enzymes: a prototype apparatus for oxidase enzymes in chemical analysis utilizing covalently bound glucose oxidase. , 1973, Analytical biochemistry.

[23]  Christie G. Enke,et al.  A Modular Twin Bus Microprocessor System for Laboratory Automation. , 1984 .

[24]  T. Yao,et al.  Flow injection analysis for glucose by the combined use of an immobilized glucose oxidase reactor and a peroxidase electrode , 1984 .