A new microcontroller-based RADFET dosimeter reader

Abstract A new reader for radiation dose measurements using RADFET (pMOSFET) dosemeters has been developed. The threshold voltage ( V T ) of the pMOSFETs is measured using a “one-point” method that determines V T as the gate voltage for a given drain current. Using V T , the absorbed dose, which is directly proportional to the threshold voltage shift, is calculated. The reader is based on a low cost 8-bit PIC 18F4520 microcontroller (MCU), and works independently of a personal computer, uses a touch screen and stores the data in microcontroller memory. Good agreement in threshold voltage values, obtained using a high-quality source-measure unit and the reader, was obtained. In addition, the reader can be used for threshold voltage measurement with other types of MOSFETs, especially in long duration experiments, as well as for the real-time measurements in radiotherapy, either as an autonomous system or integrated in a larger monitoring configuration.

[1]  Per H Halvorsen,et al.  Dosimetric evaluation of a new design MOSFET in vivo dosimeter. , 2004, Medical physics.

[2]  N Suchowerska,et al.  Clinical application of the OneDose™ Patient Dosimetry System for total body irradiation , 2005, Physics in medicine and biology.

[3]  Goran S. Ristić,et al.  Influence of ionizing radiation and hot carrier injection on metal-oxide-semiconductor transistors , 2008 .

[4]  A. Faigón,et al.  Electrically Erasable Metal–Oxide–Semiconductor Dosimeters , 2007, IEEE Transactions on Nuclear Science.

[5]  Muhammad Arsalan,et al.  Wireless Dosimeter: System-on-Chip Versus System-in-Package for Biomedical and Space Applications , 2008, IEEE Transactions on Circuits and Systems II: Express Briefs.

[6]  A. Albadri,et al.  The empirical dependence of radiation-induced charge neutralization on negative bias in dosimeters based on the metal-oxide-semiconductor field-effect transistor , 2006 .

[7]  A B Rosenfeld,et al.  MOSFET dosimetry on modern radiation oncology modalities. , 2002, Radiation protection dosimetry.

[8]  Andrew Holmes-Siedle,et al.  The space-charge dosimeter: General principles of a new method of radiation detection , 1974 .

[9]  E. Yilmaz,et al.  Use of Al2O3 layer as a dielectric in MOS based radiation sensors fabricated on a Si substrate , 2008 .

[10]  D. Verellen,et al.  An in-house developed resettable MOSFET dosimeter for radiotherapy , 2010, Physics in medicine and biology.

[11]  Milic M. Pejovic,et al.  Gamma-ray irradiation and post-irradiation responses of high dose range RADFETs , 2001, RADECS 2001. 2001 6th European Conference on Radiation and Its Effects on Components and Systems (Cat. No.01TH8605).

[12]  E. B. Gurp In vivo dosimetry using MOSFET detectors in radiotherapy , 2009 .

[13]  Alberto J. Palma,et al.  Readout techniques for linearity and resolution improvements in MOSFET dosimeters , 2010 .

[14]  L. Adams,et al.  RADFET: A review of the use of metal-oxide-silicon devices as integrating dosimeters , 1986 .

[15]  A. Gloskovskii,et al.  Time-of-flight photoelectron spectromicroscopy of single MoS2 nanotubes , 2006 .

[16]  Energy and integrated dose dependence of MOSFET dosimeter sensitivity for irradiation energies between 30kV and Co60. , 2006, Medical physics.

[17]  Evaluation of commercial programmable floating gate devices as radiation dosimeters , 2009 .