An Analytical Equivalent Circuit Model for Optimization Design of a Broadband Piezoelectric Micromachined Ultrasonic Transducer With an Annular Diaphragm

This paper presents an equivalent circuit model, a systematic design, and optimization method for developing a broadband annular diaphragm piezoelectric micromachined ultrasonic transducer (A-PMUT). By utilizing array analysis methods, an annular diaphragm is regarded as an array consisting of equally spaced sector diaphragms influencing each other by crosstalk effect. The model successfully explains the phenomenon of multi-resonance peaks in the frequency response curve, sharing the same vibration mode. The study finds that the analytical predictions of the model are in good agreement with the simulation and experimental results. Meanwhile, based on the phenomenon of multi-resonance peaks, a systematic design method is proposed to extend the bandwidth of the A-PMUT. In this method, the radiation impedance of the A-PMUT is separated into crosstalk-free and crosstalk contributed parts. This method enables the determination of the optimal structure counting for the influences on the frequency response of A-PMUTs for broadband applications. The model here can also be further generalized to be a guideline for the design and optimization of broadband PMUTs.

[1]  Charles H. Sherman,et al.  Transducers and Arrays for Underwater Sound , 2008 .

[2]  Bernhard E. Boser,et al.  11.8 Integrated ultrasonic system for measuring body-fat composition , 2015, 2015 IEEE International Solid-State Circuits Conference - (ISSCC) Digest of Technical Papers.

[3]  Sang-Gook Kim,et al.  Working equations of a circular multimorph piezoelectric micromachined ultrasonic transducer , 2012, IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society.

[4]  Liwei Lin,et al.  Broadband ring-shaped PMUTS based on an acoustically induced resonance , 2017, 2017 IEEE 30th International Conference on Micro Electro Mechanical Systems (MEMS).

[5]  Liwei Lin,et al.  An accurate equivalent circuit for the clamped circular multiple-electrode PMUT with residual stress , 2013, 2013 IEEE International Ultrasonics Symposium (IUS).

[6]  Sang-Gook Kim,et al.  Analytic solution for N-electrode actuated piezoelectric disk with application to piezoelectric micromachined ultrasonic transducers , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[7]  J. Xie,et al.  Highly Accurate Airflow Volumetric Flowmeters via pMUTs Arrays Based on Transit Time , 2019, Journal of Microelectromechanical Systems.

[8]  Chengkuo Lee,et al.  Micromachined piezoelectric ultrasonic transducer with ultra-wide frequency bandwidth , 2015 .

[9]  O. Oralkan,et al.  Next-gen ultrasound , 2009, IEEE Spectrum.

[10]  Martin Schoeppler,et al.  Three-dimensional micro electromechanical system piezoelectric ultrasound transducer , 2012 .

[11]  T. Ikeda Fundamentals of piezoelectricity , 1990 .

[12]  J. Ryu,et al.  Review of piezoelectric micromachined ultrasonic transducers and their applications , 2017 .

[13]  Firas Sammoura,et al.  Multiple electrode piezoelectric micromachined ultrasonic transducers , 2014, 2014 IEEE International Ultrasonics Symposium.

[14]  Paul D. Wilcox,et al.  Ultrasonic arrays for non-destructive evaluation: A review , 2006 .

[15]  Norman William. McLachlan Loud speakers : Theory, performance, testing and design , 1960 .

[16]  R. Guldiken,et al.  MEMS ultrasonic transducers for biomedical applications , 2012 .

[17]  Yufeng Zhou,et al.  Enhancement of the Transmission of Piezoelectric Micromachined Ultrasonic Transducer With an Isolation Trench , 2016, Journal of Microelectromechanical Systems.

[18]  Firas Sammoura,et al.  Optimizing the electrode size of circular bimorph plates with different boundary conditions for maximum deflection of piezoelectric micromachined ultrasonic transducers. , 2013, Ultrasonics.

[19]  D. Blackstock Fundamentals of Physical Acoustics , 2000 .

[20]  Bernhard E. Boser,et al.  12.1 3D ultrasonic gesture recognition , 2014, 2014 IEEE International Solid-State Circuits Conference Digest of Technical Papers (ISSCC).

[21]  A. Atalar,et al.  Radiation impedance of an array of circular capacitive micromachined ultrasonic transducers , 2010, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[22]  Liwei Lin,et al.  An equivalent circuit model for curved piezoelectric micromachined ultrasonic transducers with spherical-shape diaphragms , 2014, 2014 IEEE International Ultrasonics Symposium.

[23]  D J Hagler,et al.  Two-dimensional real-time ultrasonic imaging of the heart and great vessels. Technique, image orientation, structure identification, and validation. , 1978, Mayo Clinic proceedings.

[24]  Richard J. Przybyla,et al.  Improved acoustic coupling of air-coupled micromachined ultrasonic transducers , 2014, 2014 IEEE 27th International Conference on Micro Electro Mechanical Systems (MEMS).

[25]  K. Kirk Shung,et al.  Ultrasonic transducers and arrays , 1996 .

[26]  Firas Sammoura,et al.  An analytical analysis of the sensitivity of circular piezoelectric micromachined ultrasonic transducers to residual stress , 2012, 2012 IEEE International Ultrasonics Symposium.

[27]  A. Atalar,et al.  Rayleigh–bloch waves in CMUT arrays , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[28]  Yongqiang Qiu,et al.  Piezoelectric Micromachined Ultrasound Transducer (PMUT) Arrays for Integrated Sensing, Actuation and Imaging , 2015, Sensors.

[29]  Liwei Lin,et al.  Bimorph Piezoelectric Micromachined Ultrasonic Transducers , 2016, Journal of Microelectromechanical Systems.

[30]  B. Boser,et al.  Short-range and high-resolution ultrasound imaging using an 8 MHz aluminum nitride PMUT array , 2015, 2015 28th IEEE International Conference on Micro Electro Mechanical Systems (MEMS).

[31]  Abdullah Atalar,et al.  An improved lumped element nonlinear circuit model for a circular CMUT cell , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[32]  R. Pritchard Mutual Acoustic Impedance between Radiators in an Infinite Rigid Plane , 1960 .

[33]  D. Horsley,et al.  Highly responsive curved aluminum nitride pMUT , 2014, 2014 IEEE 27th International Conference on Micro Electro Mechanical Systems (MEMS).

[34]  Paul Lukowicz,et al.  Using ultrasonic hand tracking to augment motion analysis based recognition of manipulative gestures , 2005, Ninth IEEE International Symposium on Wearable Computers (ISWC'05).

[35]  J. Reddy Theory and Analysis of Elastic Plates and Shells , 2006 .

[36]  Annett Wechsler,et al.  Formulas For Natural Frequency And Mode Shape , 2016 .

[37]  Liwei Lin,et al.  An analytical solution for curved piezoelectric micromachined ultrasonic transducers with spherically shaped diaphragms , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[38]  P.-C. Eccardt,et al.  Linear and nonlinear equivalent circuit modeling of CMUTs , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[39]  Sang-Gook Kim,et al.  Experiment and simulation validated analytical equivalent circuit model for piezoelectric micromachined ultrasonic transducers , 2015, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[40]  H. Koymen,et al.  Equivalent circuit-based analysis of CMUT cell dynamics in arrays , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[41]  Liwei Lin,et al.  Equivalent Circuit Models for Large Arrays of Curved and Flat Piezoelectric Micromachined Ultrasonic Transducers , 2016, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[42]  Liwei Lin,et al.  RING-SHAPED PIEZOELECTRIC MICROMACHINED ULTRASONIC TRANSDUCERS (PMUT) WITH INCREASED PRESSURE GENERATION , 2016 .

[43]  Samir Mitragotri,et al.  Healing sound: the use of ultrasound in drug delivery and other therapeutic applications , 2005, Nature Reviews Drug Discovery.

[44]  J F Dias Construction and Performance of an Experimental Phased Array Acoustic Imaging Transducer , 1981, Ultrasonic imaging.

[45]  Kullervo Hynynen,et al.  Overview of Therapeutic Ultrasound Applications and Safety Considerations , 2012, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[46]  Xiaoyue Jiang,et al.  3-D Ultrasonic Fingerprint Sensor-on-a-Chip , 2016, IEEE Journal of Solid-State Circuits.

[47]  B. Boser,et al.  Piezoelectric micromachined ultrasonic transducers for human-machine interfaces and biometric sensing , 2015, 2015 IEEE SENSORS.

[48]  B.T. Khuri-Yakub,et al.  Analytically calculating membrane displacement and the equivalent circuit model of a circular CMUT cell , 2008, 2008 IEEE Ultrasonics Symposium.