Broad-band Mach-Zehnder interferometers as high performance refractive index sensors: theory and monolithic implementation.

Broad-band Mach-Zehnder interferometry is analytically described and experimentally demonstrated as an analytical tool capable of high accuracy refractive index measurements over a wide spectral range. Suitable photonic engineering of the interferometer sensing and reference waveguides result in sinusoidal TE and TM spectra with substantially different eigen-frequencies. This allows for the instantaneous deconvolution of multiplexed polarizations and enables large spectral shifts and noise reduction through filtering in the Fourier Transform domain. Due to enhanced sensitivity, optical systems can be designed that employ portable spectrum analyzers with nm range resolution without compromising the sensor analytical capability. Practical detection limits in the 10(-6)-10(-7) RIU range are achievable, including temperature effects. Finally, a proof of concept device is realized on a silicon microphotonic chip that monolithically integrates broad-band light sources and single mode silicon nitride waveguides. Refractive index detection limits rivaling that of ring resonators with externally coupled laser sources are demonstrated. Sensitivities of 20 μm/RIU and spectral shifts in the tens of a pm are obtained.

[1]  Ioannis Raptis,et al.  Integrated optical frequency-resolved Mach-Zehnder interferometers for label-free affinity sensing. , 2010, Optics express.

[2]  R. Heideman,et al.  Remote opto-chemical sensing with extreme sensitivity: design, fabrication and performance of a pigtailed integrated optical phase-modulated Mach-Zehnder interferometer system , 1999 .

[3]  Carlo Edoardo Campanella,et al.  Label-free optical resonant sensors for biochemical applications , 2013 .

[4]  Mario La Notte,et al.  Ultra high sensitivity chemical photonic sensing by Mach–Zehnder interferometer enhanced Vernier-effect , 2013 .

[5]  A. G. Chynoweth,et al.  Photon Emission from Avalanche Breakdown in Silicon , 1956 .

[6]  Ioannis Raptis,et al.  A monolithic photonic microcantilever device for in situ monitoring of volatile compounds. , 2009, Lab on a chip.

[7]  Xudong Fan,et al.  On the performance quantification of resonant refractive index sensors. , 2008, Optics express.

[8]  Konstantinos Misiakos,et al.  Real-time detection of BRCA1 gene mutations using a monolithic silicon optocoupler array. , 2009, Biosensors & bioelectronics.

[9]  Konstantinos Misiakos,et al.  A monolithic silicon optoelectronic transducer as a real-time affinity biosensor. , 2004, Analytical chemistry.

[10]  Zeger Hens,et al.  Selective and reversible ammonia gas detection with nanoporous film functionalized silicon photonic micro-ring resonator. , 2012, Optics express.

[11]  Yuze Sun,et al.  Sensitive optical biosensors for unlabeled targets: a review. , 2008, Analytica chimica acta.

[12]  Guo-Qiang Lo,et al.  Highly sensitive Mach–Zehnder interferometer biosensor based on silicon nitride slot waveguide , 2013 .

[13]  Laura M Lechuga,et al.  All-optical phase modulation for integrated interferometric biosensors. , 2012, Optics express.