A Multimodal, SU-8 - Platinum - Polyimide Microelectrode Array for Chronic In Vivo Neurophysiology

Utilization of polymers as insulator and bulk materials of microelectrode arrays (MEAs) makes the realization of flexible, biocompatible sensors possible, which are suitable for various neurophysiological experiments such as in vivo detection of local field potential changes on the surface of the neocortex or unit activities within the brain tissue. In this paper the microfabrication of a novel, all-flexible, polymer-based MEA is presented. The device consists of a three dimensional sensor configuration with an implantable depth electrode array and brain surface electrodes, allowing the recording of electrocorticographic (ECoG) signals with laminar ones, simultaneously. In vivo recordings were performed in anesthetized rat brain to test the functionality of the device under both acute and chronic conditions. The ECoG electrodes recorded slow-wave thalamocortical oscillations, while the implanted component provided high quality depth recordings. The implants remained viable for detecting action potentials of individual neurons for at least 15 weeks.

[1]  Takafumi Suzuki,et al.  Simultaneous recording of ECoG and intracortical neuronal activity using a flexible multichannel electrode-mesh in visual cortex , 2011, NeuroImage.

[2]  Evon S. Ereifej,et al.  Comparative assessment of iridium oxide and platinum alloy wires using an in vitro glial scar assay , 2013, Biomedical Microdevices.

[3]  Chih-Wei Chang,et al.  A Wireless and Batteryless Microsystem with Implantable Grid Electrode/3-Dimensional Probe Array for ECoG and Extracellular Neural Recording in Rats , 2013, 2011 16th International Solid-State Sensors, Actuators and Microsystems Conference.

[4]  Juha Töyräs,et al.  Fabrication and testing of polyimide-based microelectrode arrays for cortical mapping of evoked potentials. , 2009, Biosensors & bioelectronics.

[5]  Nima Dehghani,et al.  The Human K-Complex Represents an Isolated Cortical Down-State , 2009, Science.

[6]  S. Hughes,et al.  The slow (<1 Hz) rhythm of non-REM sleep: a dialogue between three cardinal oscillators , 2010, Nature Neuroscience.

[7]  P H Crandall,et al.  Brain tissue reaction to some chronically implanted metals. , 1970, Journal of neurosurgery.

[8]  I. Ulbert,et al.  A polymer-based spiky microelectrode array for electrocorticography , 2015 .

[9]  Kensall D. Wise,et al.  Integrated sensors, MEMS, and microsystems: Reflections on a fantastic voyage , 2007 .

[10]  Lynn Hazan,et al.  Klusters, NeuroScope, NDManager: A free software suite for neurophysiological data processing and visualization , 2006, Journal of Neuroscience Methods.

[11]  Y. Chen,et al.  Design and fabrication of a polyimide-based microelectrode array: Application in neural recording and repeatable electrolytic lesion in rat brain , 2009, Journal of Neuroscience Methods.

[12]  Rosa Villa,et al.  SU-8 based microprobes for simultaneous neural depth recording and drug delivery in the brain. , 2013, Lab on a chip.

[13]  R. Mattson,et al.  Intracerebral masses in patients with intractable partial epilepsy , 1984, Neurology.

[14]  E. Halgren,et al.  Laminar Analysis of Human Neocortical Interictal Spike Generation and Propagation: Current Source Density and Multiunit Analysis In Vivo , 2004, Epilepsia.

[15]  Alfredo Fontanini,et al.  Ketamine-Xylazine-Induced Slow (< 1.5 Hz) Oscillations in the Rat Piriform (Olfactory) Cortex Are Functionally Correlated with Respiration , 2003, The Journal of Neuroscience.

[16]  Barjor Gimi,et al.  In vitro and in vivo evaluation of SU-8 biocompatibility. , 2013, Materials science & engineering. C, Materials for biological applications.

[17]  P. Renaud,et al.  Flexible polyimide probes with microelectrodes and embedded microfluidic channels for simultaneous drug delivery and multi-channel monitoring of bioelectric activity. , 2004, Biosensors & bioelectronics.

[18]  Vikramaditya G. Yadav,et al.  Cell and protein compatibility of parylene-C surfaces. , 2007, Langmuir : the ACS journal of surfaces and colloids.

[19]  Thomas Stieglitz,et al.  The effects of annealing on mechanical, chemical, and physical properties and structural stability of Parylene C , 2013, Biomedical microdevices.

[20]  Yasushi Miyagi,et al.  Correlation between scalp-recorded electroencephalographic and electrocorticographic activities during ictal period , 2007, Seizure.

[21]  D. Barth,et al.  Spatiotemporal organization of fast (>200 Hz) electrical oscillations in rat Vibrissa/Barrel cortex. , 1999, Journal of neurophysiology.

[22]  T. Stieglitz,et al.  Polymers for neural implants , 2011 .

[23]  M. Ward,et al.  Toward a comparison of microelectrodes for acute and chronic recordings , 2009, Brain Research.

[24]  T. Stieglitz,et al.  A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve. , 2010, Biosensors & bioelectronics.

[25]  K. Wise,et al.  An integrated-circuit approach to extracellular microelectrodes. , 1970, IEEE transactions on bio-medical engineering.

[26]  M. Steriade,et al.  A novel slow (< 1 Hz) oscillation of neocortical neurons in vivo: depolarizing and hyperpolarizing components , 1993, The Journal of neuroscience : the official journal of the Society for Neuroscience.

[27]  István Ulbert,et al.  Multiple microelectrode-recording system for human intracortical applications , 2001, Journal of Neuroscience Methods.

[28]  Patrick Ruther,et al.  In vivo validation of the electronic depth control probes , 2014, Biomedizinische Technik. Biomedical engineering.

[29]  T. Stieglitz,et al.  Micromachined, Polyimide-Based Devices for Flexible Neural Interfaces , 2000 .

[30]  Hidenori Sugano,et al.  Efficacy of intraoperative electrocorticography for assessing seizure outcomes in intractable epilepsy patients with temporal-lobe-mass lesions , 2007, Seizure.

[31]  David J. Anderson,et al.  Novel multi-sided, microelectrode arrays for implantable neural applications , 2011, Biomedical microdevices.

[32]  E. Halgren,et al.  Laminar analysis of slow wave activity in humans. , 2010, Brain : a journal of neurology.

[33]  Kensuke Kawai,et al.  Simultaneous Recording of Single-Neuron Activities and Broad-Area Intracranial Electroencephalography: Electrode Design and Implantation Procedure , 2013, Neurosurgery.

[34]  P. Renaud,et al.  Demonstration of cortical recording using novel flexible polymer neural probes , 2008 .

[35]  M M Haglund,et al.  Intraoperative hippocampal electrocorticography to predict the extent of hippocampal resection in temporal lobe epilepsy surgery. , 2000, Journal of neurosurgery.

[36]  T. Stieglitz,et al.  A biohybrid system to interface peripheral nerves after traumatic lesions: design of a high channel sieve electrode. , 2002, Biosensors & bioelectronics.

[37]  G. Paxinos,et al.  The Rat Brain in Stereotaxic Coordinates , 1983 .

[38]  Maxim Volgushev,et al.  Properties of Slow Oscillation during Slow-Wave Sleep and Anesthesia in Cats , 2011, The Journal of Neuroscience.

[39]  Babak Ziaie,et al.  A hybrid PDMS-Parylene subdural multi-electrode array , 2013, Biomedical microdevices.

[40]  J. Anthony Movshon,et al.  Comparison of Recordings from Microelectrode Arrays and Single Electrodes in the Visual Cortex , 2007, The Journal of Neuroscience.

[41]  Gergely Marton,et al.  In Vivo Measurements With Robust Silicon-Based Multielectrode Arrays With Extreme Shaft Lengths , 2013, IEEE Sensors Journal.

[42]  István Ulbert,et al.  Durability of high surface area platinum deposits on microelectrode arrays for acute neural recordings , 2014, Journal of Materials Science: Materials in Medicine.

[43]  Maxim Volgushev,et al.  Origin of Active States in Local Neocortical Networks during Slow Sleep Oscillation , 2010, Cerebral cortex.

[44]  István Ulbert,et al.  A novel multisite silicon probe for high quality laminar neural recordings , 2011 .

[45]  G. Kotzar,et al.  Evaluation of MEMS materials of construction for implantable medical devices. , 2002, Biomaterials.

[46]  K. VANSELOW,et al.  Untersuchungen über die elektrostatisch-mechanischen Kräfte an der Nervenmembran bei der Auslösung des Aktionspotentials , 1966 .

[47]  Brian J. Kim,et al.  3D Parylene sheath neural probe for chronic recordings , 2013, Journal of neural engineering.

[48]  S. Micera,et al.  Development, manufacturing and application of double-sided flexible implantable microelectrodes , 2014, Biomedical microdevices.

[49]  K. Cheung Implantable microscale neural interfaces , 2007, Biomedical microdevices.

[50]  P. Tresco,et al.  Response of brain tissue to chronically implanted neural electrodes , 2005, Journal of Neuroscience Methods.

[51]  James Weiland,et al.  Artificial vision: needs, functioning, and testing of a retinal electronic prosthesis. , 2009, Progress in brain research.