OPTICS; ATOMS and MOLECULES; SPECTROSCOPY 1589 Progress in multipass tandem Fabry-Perot interferometry: I. A fully automated, easy to use, self-aligning spectrometer with increased stability and flexibility

A computer control for a Sandercock-type multipath tandem Fabry–Perot interferometer is described, which offers many advantages over conventionally used analog control: The range of stability is increased due to active control of the laser light intensity and the mirror dither amplitude. The alignment is fully automated enabling start of a measurement within a minute after start of align, including optionally finding the optimum focus on the sample. The software control enables a programmable series of measurements with control of, e.g., the position and rotation of the sample, the angle of light incidence, the sample temperature, or the strength and direction of an applied magnetic field. Built-in fitting routines allow for a precise determination of frequency positions of excitation peaks combined with increased frequency accuracy due to a correction of a residual nonlinearity of the mirror stage drive.

[1]  D. Bechtle Digital stabilizer for scanning Fabry–Perot , 1976 .

[2]  S. Lindsay,et al.  Linear scanning circuit for a piezoelectrically controlled Fabry–Perot etalon , 1977 .

[3]  J. R. Sanderocock Light scattering from surface acoustic phonons in metals and semiconductors , 1978 .

[4]  S. Lindsay,et al.  Construction and alignment of a high performance multipass vernier tandem Fabry–Perot interferometer , 1981 .

[5]  R. Aarts,et al.  Tandem multipass Fabry-Perot interferometer for Brillouin scattering. , 1981, Applied optics.

[6]  J. R. Sandercock,et al.  Trends in brillouin scattering: Studies of opaque materials, supported films, and central modes , 1982 .

[7]  J. R. Sandercock A Dynamic Antivibration System , 1987, Other Conferences.

[8]  B. Hillebrands,et al.  Construction and performance of a Brillouin scattering set-up using a triple-pass tandem Fabry-Perot interferometer , 1987 .

[9]  Stamps,et al.  Magnetic anisotropies of ultrathin Co(001) films on Cu(001). , 1992, Physical review letters.

[10]  A. Yoshihara Construction of a Vernier Tandem (3+3)-Pass Brillouin Spectrometer and Its Application to Surface Acoustic Wave Study in Metallic Multilayer Films. , 1994 .

[11]  Roberts,et al.  Suppression of the magnetocrystalline bulk anisotropy in thin epitaxial Co(110) films on Cu(110). , 1996, Physical review. B, Condensed matter.

[12]  R. Bukowski,et al.  Fabry–Perot interferometer in Brillouin scattering experiments , 1996 .

[13]  B. Hillebrands,et al.  Interface anisotropy and magnetization reversal in epitaxial Fe(001)/Pd double layers , 1997 .

[14]  B. Hillebrands,et al.  DIRECT OBSERVATION OF TWO-DIMENSIONAL SELF-FOCUSING OF SPIN WAVES IN MAGNETIC FILMS , 1997 .

[15]  B. Hillebrands,et al.  ABSENCE OF ELASTIC ANOMALIES FOR CO/NI SUPERLATTICES WITH OSCILLATORY TRANSPORT , 1997 .

[16]  C. Chappert,et al.  Brillouin light scattering investigations of structured permalloy films , 1997 .

[17]  K. Weishaupt,et al.  A new design for a versatile Fabry-Pérot interferometer for Brillouin spectroscopy , 1997 .

[18]  C. Chappert,et al.  Anisotropic magnetic coupling of permalloy micron dots forming a square lattice , 1997 .

[19]  C. Chappert,et al.  Lateral quantization of spin waves in micron size magnetic wires , 1998 .

[20]  B. Hillebrands,et al.  Brillouin light scattering investigations of exchange biased (110)-oriented NiFe/FeMn bilayers , 1998 .

[21]  Burkard Hillebrands,et al.  Observation of spatiotemporal self-focusing of spin waves in magnetic films , 1998 .

[22]  Matthew T. Johnson,et al.  Correlation between structure and magnetic anisotropies of Co on Cu(110) , 1998 .

[23]  B. Hillebrands Brillouin light scattering from layered magnetic structures , 2000 .