Efficient Joint Estimation of Tracer Distribution and Background Signals in Magnetic Particle Imaging Using a Dictionary Approach

Background signals are a primary source of artifacts in magnetic particle imaging and limit the sensitivity of the method since background signals are often not precisely known and vary over time. The state-of-the art method for handling background signals uses one or several background calibration measurements with an empty scanner bore and subtracts a linear combination of these background measurements from the actual particle measurement. This approach yields satisfying results in case that the background measurements are taken in close proximity to the particle measurement and when the background signal drifts linearly. In this work, we propose a joint estimation of particle distribution and background signal based on a dictionary that is capable of representing typical background signals. Reconstruction is performed frame-by-frame with minimal assumptions on the temporal evolution of background signals. Thus, even non-linear temporal evolution of the latter can be captured. Using a singular-value decomposition, the dictionary is derived from a large number of background calibration scans that do not need to be recorded in close proximity to the particle measurement. The dictionary is sufficiently expressive and represented by its principle components. The proposed joint estimation of particle distribution and background signal is expressed as a linear Tikhonov-regularized least squares problem, which can be efficiently solved. In phantom experiments it is shown that the method strongly suppresses background artifacts and even allows to estimate and remove the direct feed-through of the excitation field.

[1]  B Gleich,et al.  Weighted iterative reconstruction for magnetic particle imaging , 2010, Physics in medicine and biology.

[2]  Paris Smaragdis,et al.  Singing-voice separation from monaural recordings using robust principal component analysis , 2012, 2012 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP).

[3]  T Knopp,et al.  Correction of linear system drifts in magnetic particle imaging , 2019, Physics in medicine and biology.

[4]  Bernhard Gleich,et al.  Quantitative “Hot-Spot” Imaging of Transplanted Stem Cells Using Superparamagnetic Tracers and Magnetic Particle Imaging , 2015, Tomography.

[5]  Mark A Griswold,et al.  Magnetic Particle Imaging Tracers: State-of-the-Art and Future Directions. , 2015, The journal of physical chemistry letters.

[6]  Sanjiv Sam Gambhir,et al.  Tomographic magnetic particle imaging of cancer targeted nanoparticles. , 2017, Nanoscale.

[7]  T Knopp,et al.  Online reconstruction of 3D magnetic particle imaging data , 2016, Physics in medicine and biology.

[8]  T Knopp,et al.  Hybrid system calibration for multidimensional magnetic particle imaging , 2017, Physics in medicine and biology.

[9]  Lawrence L. Wald,et al.  Rodent Cerebral Blood Volume (CBV) changes during hypercapnia observed using Magnetic Particle Imaging (MPI) detection , 2018, NeuroImage.

[10]  J. Duerk,et al.  Magnetic Resonance Fingerprinting , 2013, Nature.

[11]  Tobias Knopp,et al.  MPIReco.jl: Julia Package for Image Reconstruction in MPI , 2019 .

[12]  Tobias Knopp,et al.  Sensitivity Enhancement in Magnetic Particle Imaging by Background Subtraction , 2016, IEEE Transactions on Medical Imaging.

[13]  T Knopp,et al.  Human-sized magnetic particle imaging for brain applications , 2018, Nature Communications.

[14]  Daniel K Sodickson,et al.  Rapid and accurate T2 mapping from multi–spin‐echo data using Bloch‐simulation‐based reconstruction , 2015, Magnetic resonance in medicine.

[15]  C. Gerloff,et al.  Monitoring Intracranial Cerebral Hemorrhage Using Multi-Contrast Real-Time Magnetic Particle Imaging. , 2020, ACS nano.

[16]  Matthias Graeser,et al.  Magnetic Particle Imaging for Real-Time Perfusion Imaging in Acute Stroke. , 2017, ACS nano.

[17]  Tobias Knopp,et al.  Magnetic Particle Imaging for High Temporal Resolution Assessment of Aneurysm Hemodynamics , 2016, PloS one.

[18]  Jonathan Carter,et al.  Magnetic Particle Imaging for Highly Sensitive, Quantitative, and Safe in Vivo Gut Bleed Detection in a Murine Model. , 2017, ACS nano.

[19]  Toon van Waterschoot,et al.  Multi-channel linear prediction-based speech dereverberation with low-rank power spectrogram approximation , 2015, 2015 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP).

[20]  Jörn Borgert,et al.  Magnetic Particle Imaging (MPI): Experimental Quantification of Vascular Stenosis Using Stationary Stenosis Phantoms , 2017, PloS one.

[21]  Bernhard Gleich,et al.  Tomographic imaging using the nonlinear response of magnetic particles , 2005, Nature.

[22]  Patrick Vogel,et al.  Low Latency Real-time Reconstruction for MPI Systems , 2017 .

[23]  Volkmar Schulz,et al.  Joint Reconstruction of Tracer Distribution and Background in Magnetic Particle Imaging , 2018, IEEE Transactions on Medical Imaging.

[24]  Tobias Knopp,et al.  Magnetic particle imaging: from proof of principle to preclinical applications , 2017, Physics in medicine and biology.

[25]  Jochen Franke,et al.  System Characterization of a Highly Integrated Preclinical Hybrid MPI-MRI Scanner , 2016, IEEE Transactions on Medical Imaging.

[26]  Bo Zheng,et al.  First in vivo magnetic particle imaging of lung perfusion in rats , 2017, Physics in medicine and biology.

[27]  Emmanuel Vincent,et al.  Audio Source Separation and Speech Enhancement , 2018 .