Flow cytometric detection of micronuclei by combined staining of DNA and membranes.

A new staining method is presented for flow cytometric measurement of micronuclei (MN) in cell cultures and human lymphocytes using membrane-specific fluorescent dyes in addition to DNA staining. Several combinations of fluorescent membrane and DNA dyes were studied for a better discrimination of MN from debris in a suspension of nuclei and micronuclei. For staining of membranes, the lipophilic dyes 2-hydroxyethyl-7,12,17-tris(methoxyethyl)porphycene (HEPn) and 1,6-diphenyl-1,3,5-hexatriene (DPH) were used in combination with ethidium bromide (EB), proflavine (PF), and Hoechst 33258 (HO). Due to their spectral properties, HO or EB combined with HEPn were not as suitable for the discrimination of MN from debris as was HEPn in combination with PF. With HEPn in combination with PF, however, additional noise was found at low fluorescence intensities, probably due to free fluorescent dye molecules in the solution. The optimal simultaneous staining of membranes and DNA was obtained using a combination of DPH and EB. The induction of MN in Chinese hamster and mouse NIH-3T3 cells by UV-B illumination was studied with this new staining technique. UV-B illumination (280-360 nm) induced MN in both cell lines. Chinese hamster cells were found to be more sensitive to these wavelengths. Illumination with wavelengths above 360 nm did not induce MN in either cell line. The results obtained from human lymphocytes using the combination of EB and DPH were comparable to the results obtained with the combination of EB and HO.

[1]  G. Seckmeyer,et al.  A new sunlight simulator for ecological research on plants , 1993 .

[2]  I. B. Berlman Handbook of flourescence spectra of aromatic molecules , 1971 .

[3]  M. Fenech,et al.  Preliminary studies on scoring micronuclei by computerised image analysis. , 1988, Mutation research.

[4]  M. Nüsse,et al.  Micronuclei induced by 2-chlorobenzylidene malonitrile contain single chromosomes as demonstrated by the combined use of flow cytometry and immunofluorescent staining with anti-kinetochore antibodies. , 1992, Mutagenesis.

[5]  M. Nüsse,et al.  Factors influencing the DNA content of radiation-induced micronuclei. , 1992, International journal of radiation biology.

[6]  M. Bauchinger,et al.  Multiparametric flow cytometric analysis of radiation-induced micronuclei in mammalian cell cultures. , 1992, Cytometry.

[7]  K. Wirtz,et al.  A comparative fluorescence polarization study of cis-parinaroyl-phosphatidylcholine and diphenylhexatriene in membranes containing different amounts of cholesterol. , 1984, Chemistry and physics of lipids.

[8]  A. Tates,et al.  The present state of the automated micronucleus test for lymphocytes. , 1990, International journal of radiation biology.

[9]  A. Carrano,et al.  The DNA content of micronuclei induced in mouse bone marrow by gamma-irradiation: evidence that micronuclei arise from acentric chromosomal fragments. , 1977, Mutation research.

[10]  H. Braselmann,et al.  Flow cytometric analysis of micronuclei in the CD2+/- subpopulation of human lymphocytes enriched by magnetic separation. , 1995, International journal of radiation biology.

[11]  C. Richert A long-time-stable liposome formulation for porphyrinoid photosensitizers , 1993 .

[12]  John G. Collard,et al.  Localization of the lipid probe 1,6-diphenyl-1,3,5 hexatriene (DPH) in intact cells by fluorescence microscopy. , 1978, Experimental cell research.

[13]  M. Nüsse,et al.  Flow cytometric analysis of in vitro micronucleus induction in hepatocytes treated with carcinogens. , 1993, Toxicology in vitro : an international journal published in association with BIBRA.

[14]  K. Johanson,et al.  Microscopic and flow cytometric study of micronuclei in iododeoxyuridine labelled cells irradiated with soft x-rays. , 1990, Acta oncologica.

[15]  W Beisker,et al.  A new combined integral-light and slit-scan data analysis system (DAS) for flow cytometry. , 1994, Computer methods and programs in biomedicine.

[16]  J. Vanderkooi,et al.  Temperature dependence of 1,6-diphenyl-1,3,5-hexatriene fluorescence in phophoslipid artificial membranes. , 1976, Biochemistry.

[17]  M. Pincu,et al.  DNA content of micronuclei in human lymphocytes. , 1985, International journal of radiation biology and related studies in physics, chemistry, and medicine.

[18]  M. Nüsse,et al.  Flow cytometric analysis of micronuclei found in cells after irradiation. , 1984, Cytometry.

[19]  H. Braselmann,et al.  An automated flow cytometric micronucleus assay for human lymphocytes. , 1992, International journal of radiation biology.