Haemodynamic effects of stent diameter and compaction ratio on flow-diversion treatment of intracranial aneurysms: A numerical study of a successful and an unsuccessful case.

BACKGROUND Compacting a flow-diverting (FD) stent is an emerging technique to create a denser configuration of wires across the aneurysm ostium. However, quantitative analyses of post-stenting haemodynamics affected by the compaction level of different stent sizes remain inconclusive. OBJECTIVE To compare the aneurysmal haemodynamic alterations after virtual FD treatments with different device diameters at different compaction ratios. METHODS We virtually implanted three sizes of FD stent, with each size deployed at four compaction ratios, into two patient aneurysms previously treated with the Silk+FD-one successful case and the other unsuccessful. Wire configurations of the FD in the 24 treatment scenarios were examined, and aneurysmal haemodynamic alterations were resolved by computational fluid dynamics (CFD) simulations. We investigated the aneurysmal flow patterns, aneurysmal average velocity (AAV), mass flowrate (MF), and energy loss (EL) in each scenario. RESULTS Compactions of the stent in the successful case resulted in a greater metal coverage rate than that achieved in the unsuccessful one. A 25% increment in compaction ratio further decreased the AAV (12%), MF (11%), and EL (9%) in both cases (average values). The averaged maximum differences attributable to device size were 10% (AAV), 8% (MF), and 9% (EL). CONCLUSIONS Both stent size and compaction level could markedly affect the FD treatment outcomes. It is therefore important to individualise the treatment plan by selecting the optimal stent size and deployment procedure. CFD simulation can be used to investigate the treatment outcomes, thereby assisting doctors in choosing a favourable treatment plan.

[1]  Y. Qian,et al.  Computational Hemodynamics Analysis of Intracranial Aneurysms Treated with Flow Diverters: Correlation with Clinical Outcomes , 2014, American Journal of Neuroradiology.

[2]  Y Zhang,et al.  Investigation of intracranial aneurysm hemodynamics following flow diverter stent treatment. , 2013, Medical engineering & physics.

[3]  J. Gabrillargues,et al.  Flow-Diverter Silk Stent for the Treatment of Intracranial Aneurysms: 1-year Follow-Up in a Multicenter Study , 2012, American Journal of Neuroradiology.

[4]  J. Xiang,et al.  Enhanced Aneurysmal Flow Diversion Using a Dynamic Push-Pull Technique: An Experimental and Modeling Study , 2014, American Journal of Neuroradiology.

[5]  D. Kallmes,et al.  Patency of the ophthalmic artery after flow diversion treatment of paraclinoid aneurysms. , 2012, Journal of neurosurgery.

[7]  C. Gandhi,et al.  The Pipeline Embolization Device for the Intracranial Treatment of Aneurysms Trial , 2012 .

[8]  Amy Henderson Squilacote The Paraview Guide , 2008 .

[9]  Y. Ventikos,et al.  Personalizing flow‐diverter intervention for cerebral aneurysms: from computational hemodynamics to biochemical modeling , 2014, International journal for numerical methods in biomedical engineering.

[10]  J. Raymond,et al.  The Varying Porosity of Braided Self-Expanding Stents and Flow Diverters: An Experimental Study , 2013, American Journal of Neuroradiology.

[11]  Philipp Berg,et al.  An automatic CFD-based flow diverter optimization principle for patient-specific intracranial aneurysms. , 2015, Journal of biomechanics.

[12]  M Umezu,et al.  Risk Analysis of Unruptured Aneurysms Using Computational Fluid Dynamics Technology: Preliminary Results , 2011, American Journal of Neuroradiology.

[13]  J. Pruvo,et al.  Flow-Diverter Stent for the Endovascular Treatment of Intracranial Aneurysms: A Prospective Study in 29 Patients With 34 Aneurysms , 2010, Stroke.

[14]  Isabel Wanke,et al.  High-Profile Flow Diverter (Silk) Implantation in the Basilar Artery: Efficacy in the Treatment of Aneurysms and the Role of the Perforators , 2010, Stroke.

[15]  Philipp Berg,et al.  Endothelialization of over- and undersized flow-diverter stents at covered vessel side branches: An in vivo and in silico study. , 2016, Journal of biomechanics.

[16]  Bongjae Chung,et al.  CFD for Evaluation and Treatment Planning of Aneurysms: Review of Proposed Clinical Uses and Their Challenges , 2014, Annals of Biomedical Engineering.

[17]  Sebastian Fischer,et al.  Pipeline embolization device (PED) for neurovascular reconstruction: initial experience in the treatment of 101 intracranial aneurysms and dissections , 2011, Neuroradiology.

[18]  F. Mut,et al.  Effects of Flow-Diverting Device Oversizing on Hemodynamics Alteration in Cerebral Aneurysms , 2012, American Journal of Neuroradiology.

[19]  V. Pereira,et al.  Flow diversion treatment: intra-aneurismal blood flow velocity and WSS reduction are parameters to predict aneurysm thrombosis , 2012, Acta Neurochirurgica.

[20]  Jianping Xiang,et al.  High-fidelity virtual stenting: modeling of flow diverter deployment for hemodynamic characterization of complex intracranial aneurysms. , 2015, Journal of neurosurgery.

[21]  Hiroyuki Kosukegawa,et al.  High Fidelity Virtual Stenting (HiFiVS) for Intracranial Aneurysm Flow Diversion: In Vitro and In Silico , 2013, Annals of Biomedical Engineering.

[22]  Adnan H Siddiqui,et al.  Computer modeling of deployment and mechanical expansion of neurovascular flow diverter in patient-specific intracranial aneurysms. , 2012, Journal of biomechanics.

[23]  Jianping Xiang,et al.  Increasing flow diversion for cerebral aneurysm treatment using a single flow diverter. , 2014, Neurosurgery.

[24]  F. Mut,et al.  Analysis of Hemodynamics and Aneurysm Occlusion after Flow-Diverting Treatment in Rabbit Models , 2014, American Journal of Neuroradiology.

[25]  Chander Sadasivan,et al.  Endoluminal scaffolds for vascular reconstruction and exclusion of aneurysms from the cerebral circulation. , 2010, Stroke.

[26]  Gouthami Chintalapani,et al.  Metal coverage ratio of pipeline embolization device for treatment of unruptured aneurysms: Reality check , 2016, Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences.

[27]  K Spranger,et al.  Comparison and calibration of a real-time virtual stenting algorithm using Finite Element Analysis and Genetic Algorithms , 2015, Computer methods in applied mechanics and engineering.

[28]  David A. Steinman,et al.  Image-Based Computational Fluid Dynamics Modeling in Realistic Arterial Geometries , 2002, Annals of Biomedical Engineering.

[29]  Y. Ventikos,et al.  Towards Predicting Patient-Specific Flow-Diverter Treatment Outcomes for Bifurcation Aneurysms: From Implantation Rehearsal to Virtual Angiograms , 2015, Annals of Biomedical Engineering.