True Aneurysm in a Femoro-Popliteal Dacron Graft — A Case Report and Literature Review

Infection and anastomotic pseudo-aneurysm formation are the usually reported complications in the use of dacron prosthesis in arterial by-pass surgery. We report a case of true aneurysm formation in the body of a knitted dacron graft used to by-pass a symptomatic above knee occlusion of the superficial femoral artery when suitable long saphenous vein was not available. This was diagnosed 10 years after surgery. A true aneurysm may be a result of pre-implantation trauma to the graft or to late fibre degeneration. Microscopic examination revealed that the dacron fibres had stretched to form a local aneurysm before rupturing to form an associated false aneurysm. Two other areas of the graft had small saccular aneurysms without rupture. The damaged portion was excised and replaced by an interposition graft of the same material.

[1]  A. AbuRahma,et al.  Multiple nonanastomotic aneurysms in an external velour ringed Dacron femoropopliteal vascular prosthesis , 1995, Annals of vascular surgery.

[2]  P. Aarnio,et al.  Dacron Graft Aneurysm: A Report of Five Cases , 1992 .

[3]  K. Sugimachi,et al.  Recurrent multiple aneurysms in an axillofemoral graft with coagulopathy. , 1990, Acta chirurgica Scandinavica.

[4]  A. Zelikovski,et al.  True aneurysm in a prosthetic aorto-femoral dacron graft. , 1989, The Journal of cardiovascular surgery.

[5]  K. Sugimachi,et al.  Aneurysm in a double velour knitted Dacron graft. , 1987, The Journal of cardiovascular surgery.

[6]  J. W. Lord,et al.  Aneurysm and seroma formation in a velour Dacron prosthesis. , 1986, New York state journal of medicine.

[7]  M. Truini,et al.  Multiple aneurysmal dilatations in a knitted dacron velour graft. , 1985, The Journal of cardiovascular surgery.

[8]  W. Gryboski,et al.  Aneurysms of a double velour aortic graft. , 1984, Archives of surgery.

[9]  J. E. Hutton,et al.  Dilation of knitted Dacron aortic prostheses and anastomotic false aneurysms: etiologic considerations. , 1983, Surgery.

[10]  L. Sauvage,et al.  Late fiber deterioration in Dacron arterial grafts. , 1981, Annals of surgery.

[11]  M. Koopmann,et al.  Degenerative changes in Dacron external velour vascular prostheses (a report of three cases). , 1980, The Journal of cardiovascular surgery.

[12]  T. Riles,et al.  Dilation of synthetic grafts and junctional aneurysms. , 1979, Archives of surgery.

[13]  M. H. Freeman,et al.  Postoperative Alterations in Size of Dacron Aortic Grafts: An Ultrasonic Evaluation , 1979, Annals of surgery.

[14]  A. Gerein,et al.  True aneurysms in prosthetic femoropopliteal grafts. , 1978, The American surgeon.

[15]  J. May,et al.  Multiple aneurysms in dacron velour graft. , 1978, Archives of Surgery.

[16]  M. Webster,et al.  Aneurysm formation in expanded polytetrafluoroethylene prostheses. , 1976, Review of surgery.

[17]  R. Darling,et al.  Failure of ultralightweight knitted Dacron grafts in arterial reconstruction. , 1976, Archives of surgery.