The numerical calculation of heat transfer performance for annular flow of liquid nitrogen in a vertical annular channel

Abstract According to a separated phase flow model for vertical annular two-phase flow in an annular channel, the liquid film thickness, distributions of velocities and temperatures in the liquid layer are predicted in the range of heat fluxes: 6000–12000 W/m 2 , mass flux: 500–1100 kg/m 2 s . The pressure drop along the flow channel and heat transfer coefficient are also calculated. The liquid film thickness is in the order of micrometers and heat transfer coefficient is 2800–7800 W/m 2 K of liquid nitrogen boiling in narrow annular channels. The measured heat transfer coefficient is 29% higher than the calculated values. With the mass flux increasing and the gap of the annular channel decreasing, pressure drop and heat transfer coefficient increase.