Robust Thermal Performance of a Flat-Plate Oscillating Heat Pipe During High-Gravity Loading

The thermal performance of a miniature, three-dimensional flat-plate oscillating heat pipe (3D FP-OHP) was experimentally investigated during high-gravity loading with nonfavorable evaporator positioning. The heat pipe had dimensions of 3.0 x 3.0 x 0.254 cm 3 and utilized a novel design concept incorporating a two-layer channel arrangement. The device was charged with acetone and tested at a heat input of 95 W within a spin-table centrifuge. It was found that the heat pipe operated and performed near-independent of the investigated hypergravity loading up to 10 g. Results show that at ten times the acceleration due to gravity (10 g), the effective thermal conductivity was almost constant and even slightly increased which is very different from a conventional heat pipe. The gravity-independent heat transfer performance provides a unique feature of OHPs.

[1]  J. van Es,et al.  High-Acceleration Performance of the Flat Swinging Heat Pipe , 2000 .

[2]  Peng Cheng,et al.  An Investigation of Flat-Plate Oscillating Heat Pipes , 2010 .

[3]  Guoping Xu,et al.  Thermal characterization of pulsating heat pipes , 2006, Thermal and Thermomechanical Proceedings 10th Intersociety Conference on Phenomena in Electronics Systems, 2006. ITHERM 2006..

[4]  Shung-Wen Kang,et al.  Fabrication of polydimethylsiloxane (PDMS) pulsating heat pipe , 2009 .

[5]  Sameer,et al.  Visual Study on Flow and Operational Characteristics of Flat Plate ClosedLoop Pulsating Heat Pipes , 2009 .

[6]  Sameer Khandekar,et al.  Closed loop pulsating heat pipes: Part A: parametric experimental investigations , 2003 .

[7]  Hongbin Ma,et al.  Experimental Investigation of Oscillating Motions in a Flat Plate Pulsating Heat Pipe , 2007 .

[8]  S. Khandekar THERMOFLUID DYNAMIC STUDY OF FLAT-PLATE CLOSED-LOOP PULSATING HEAT PIPES , 2003 .

[9]  Daniel S. Hussey,et al.  Visual Observation of Oscillating Heat Pipes Using Neutron Radiography , 2008 .

[10]  Manfred Groll,et al.  Operational limit of closed loop pulsating heat pipes , 2008 .

[11]  Scott M. Thompson,et al.  Experimental Investigation of Miniature Three-Dimensional Flat-Plate Oscillating Heat Pipe , 2009 .

[12]  Manfred Groll,et al.  Performance characteristics of pulsating heat pipes as integral thermal spreaders , 2009 .

[13]  J. Gu,et al.  Effects of gravity on the performance of pulsating heat pipes , 2004 .

[14]  Yuwen Zhang,et al.  Advances and Unsolved Issues in Pulsating Heat Pipes , 2008 .