Energy efficiency of a reversible refrigeration unit using R410A or R32

The aim of this article is twofold: first, to compare the performance of R410A with that of R32, which is considered a possible HFC substitute with lower global warming potential (675 instead of 2088); second, to exploit the effect of the circuit length in the finned coil of a packaged air-to-water reversible unit with given water plate heat exchanger and scroll compressor. Both scopes are pursued through the analysis of a case study, a system with nominal cooling capacity of about 74 kW at 35°C dry-bulb outdoor air temperature and a nominal heating capacity of about 70 kW at 2°C dry-bulb and 1°C wet-bulb ambient temperature. The performance of the two refrigerants inside a “real” machine is simulated by means of an advanced numerical model of a packaged reversible refrigeration unit. The system consists of a single refrigerating circuit with two identical scroll compressors. The compressor was characterized by its experimental performance curve according to Standard EN 12900 (EN 2013a) for both R410A and R32. Off-the-shelf copper tubes and louvered aluminum fins were considered for the condenser and typical brazed-plate heat exchanger for the evaporator of the chiller configuration. The finned coil heat exchanger was first thermodynamically optimized for R410A and R32 for both condenser and evaporator operation with regard to the number of internal circuits according to the total temperature penalization performance evaluation criteria (Cavallini et al. 2010; Brown et al. 2013), without changing the overall heat exchanger dimensions. The effect of finned coil circuit length on the performance of the investigated reversible unit with the two refrigerants was then analyzed at nominal design conditions and under a seasonal perspective. Based on the modeling work, it is possible to conclude that R32 system efficiency performance is acceptable as alternative to R410A for packaged air-to-water reversible unit.

[1]  Ezio Fornasieri,et al.  Energy efficiency of a household air conditioner using new HFC refrigerants. , 2003 .

[2]  Marco Corradi,et al.  A simplified method to evaluate the seasonal energy performance of water chillers , 2010 .

[3]  J. M. Coulson,et al.  Heat Transfer , 2018, Finite Element Method for Solids and Structures.

[4]  Alberto Cavallini,et al.  Working fluids for mechanical refrigeration — Invited paper presented at the 19th International Congress of Refrigeration, The Hague, August 1995 , 1996 .

[5]  Hung M. Pham,et al.  R32 And HFOs As Low-GWP Refrigerants For Air Conditioning , 2012 .

[6]  Davide Del Col,et al.  An innovative model for the simulation of finned coil evaporators , 2002 .

[7]  Davide Del Col,et al.  R32 partial condensation inside a brazed plate heat exchanger , 2012 .

[8]  J. Thome,et al.  Flow pattern based two-phase frictional pressure drop model for horizontal tubes, Part II: New phenomenological model , 2007 .

[9]  P. Domanski,et al.  Performance of a finned-tube evaporator optimized for different refrigerants and its effect on system efficiency * , 2005 .

[10]  J Yu,et al.  Comparative experimental researches of air-to-water heat pump with R32 and R410A for household. , 2011 .

[11]  M. McLinden,et al.  NIST Standard Reference Database 23: Reference Fluid Thermodynamic and Transport Properties-REFPROP, Version 8.0 , 2007 .

[12]  R. M. Manglik,et al.  Experimental Study of Turbulent Flow Heat Transfer and Pressure Drop in a Plate Heat Exchanger With Chevron Plates , 1999 .

[13]  David A. Yashar,et al.  Optimization of finned-tube condensers using an intelligent system * , 2007 .

[14]  Davide Del Col,et al.  Condensation of Halogenated Refrigerants Inside Smooth Tubes , 2002 .

[15]  Z. Ayub Plate Heat Exchanger Literature Survey and New Heat Transfer and Pressure Drop Correlations for Refrigerant Evaporators , 2003 .

[16]  Reinhard Radermacher,et al.  Performance comparison of R410A and R32 in vapor injection cycles , 2013 .

[17]  M. McLinden,et al.  NIST Standard Reference Database 23: Reference Fluid Thermodynamic and Transport Properties-REFPROP, Version 9.1 | NIST , 2013 .

[18]  J. Thome,et al.  Investigation of Flow Boiling in Horizontal Tubes: Part I, A New Diabatic Two-Phase Flow Pattern Map , 2005 .

[19]  Davide Del Col,et al.  In-tube condensation performance of refrigerants considering penalization terms (exergy losses) for heat transfer and pressure drop , 2010 .

[20]  S. Rouhani,et al.  CALCULATION OF VOID VOLUME FRACTION IN THE SUBCOOLED AND QUALITY BOILING REGIONS , 1970 .

[21]  Riccardo Brignoli,et al.  Heat transfer and pressure drop penalization terms (exergy losses) during flow boiling of refrigerants , 2013 .

[22]  Susan W. Stewart,et al.  Finned-Tube Heat Exchanger Optimization Methodology , 2005 .

[23]  Andrea Gasparella,et al.  Refrigerant R134a vaporisation heat transfer and pressure drop inside a small brazed plate heat exchanger , 2007 .

[24]  J. W. Ramsey,et al.  Thermal Environmental Engineering , 1970 .