Microfab-less Microfluidic Capillary Electrophoresis Devices.

Compared to conventional bench-top instruments, microfluidic devices possess advantageous characteristics including great portability potential, reduced analysis time (minutes), and relatively inexpensive production, putting them on the forefront of modern analytical chemistry. Fabrication of these devices, however, often involves polymeric materials with less-than-ideal surface properties, specific instrumentation, and cumbersome fabrication procedures. In order to overcome such drawbacks, a new hybrid platform is proposed. The platform is centered on the use of 5 interconnecting microfluidic components that serve as the injector or reservoirs. These plastic units are interconnected using standard capillary tubing, enabling in-channel detection by a wide variety of standard techniques, including capacitively-coupled contactless conductivity detection (C4D). Due to the minimum impact on the separation efficiency, the plastic microfluidic components used for the experiments discussed herein were fabricated using an inexpensive engraving tool and standard Plexiglas. The presented approach (named 52-platform) offers a previously unseen versatility: enabling the assembly of the platform within minutes using capillary tubing that differs in length, diameter, or material. The advantages of the proposed design are demonstrated by performing the analysis of inorganic cations by capillary electrophoresis on soil samples from the Atacama Desert.

[1]  Nancy Allbritton,et al.  Surface modification of poly(dimethylsiloxane) microfluidic devices by ultraviolet polymer grafting. , 2002, Analytical chemistry.

[2]  Emanuel Carrilho,et al.  A rapid and reliable bonding process for microchip electrophoresis fabricated in glass substrates , 2010, Electrophoresis.

[3]  Peter C Hauser,et al.  High-voltage capacitively coupled contactless conductivity detection for microchip capillary electrophoresis. , 2002, Analytical chemistry.

[4]  Gang Chen,et al.  Electrophoretic microchip with dual‐opposite injection for simultaneous measurements of anions and cations , 2003, Electrophoresis.

[5]  H. Mirzadeh,et al.  Modification of polysiloxane polymers for biomedical applications: a review , 2001 .

[6]  Tingrui Pan,et al.  Fit-to-Flow (F2F) interconnects: universal reversible adhesive-free microfluidic adaptors for lab-on-a-chip systems. , 2011, Lab on a chip.

[7]  Bingcheng Lin,et al.  Electrophoretic separations on microfluidic chips , 2007, Journal of Chromatography A.

[8]  J. Kutter Liquid phase chromatography on microchips. , 2012, Journal of chromatography. A.

[9]  P. Morin,et al.  Effect of the concentration of 18-crown-6 added to the electrolyte upon the separation of ammonium, alkali and alkaline-earth cations by capillary electrophoresis , 1995 .

[10]  Y. Wang,et al.  Capillary Modification by Noncovalent Polycation Adsorption: Effects of Polymer Molecular Weight and Adsorption Ionic Strength , 1999 .

[11]  M. Parameswaran,et al.  Microwave-induced, thermally assisted solvent bonding for low-cost PMMA microfluidic devices , 2010 .

[12]  Claudimir Lucio do Lago,et al.  Unmanned platform for long‐range remote analysis of volatile compounds in air samples , 2012, Electrophoresis.

[13]  W. Coltro,et al.  Instrumentation design for hydrodynamic sample injection in microchip electrophoresis: A review , 2012, Electrophoresis.

[14]  G. Whitesides,et al.  Patterned paper as a platform for inexpensive, low-volume, portable bioassays. , 2007, Angewandte Chemie.

[15]  Jana Lauzon,et al.  An inexpensive and portable microchip-based platform for integrated RT-PCR and capillary electrophoresis. , 2008, The Analyst.

[16]  Steven A Soper,et al.  Physiochemical properties of various polymer substrates and their effects on microchip electrophoresis performance. , 2006, Journal of chromatography. A.

[17]  I. Rodríguez,et al.  Capacitively coupled contactless conductivity detection with dual top–bottom cell configuration for microchip electrophoresis , 2010, Electrophoresis.

[18]  Mark A Burns,et al.  Microfluidic assembly blocks. , 2008, Lab on a chip.

[19]  H. Becker,et al.  Polymer microfluidic devices. , 2002, Talanta.

[20]  Lucas Blanes,et al.  Understanding Capacitively Coupled Contactless Conductivity Detection in Capillary and Microchip Electrophoresis. Part 2. Peak Shape, Stray Capacitance, Noise, and Actual Electronics , 2005 .

[21]  Martin Pumera,et al.  Contactless conductivity detector for microchip capillary electrophoresis. , 2002, Analytical chemistry.

[22]  Detlev Belder,et al.  Surface modification in microchip electrophoresis , 2003, Electrophoresis.

[23]  Xue-feng Yin,et al.  Negative pressure pinched sample injection for microchip-based electrophoresis. , 2006, Lab on a chip.

[24]  Paulo T. Garcia,et al.  Polyester‐toner electrophoresis microchips with improved analytical performance and extended lifetime , 2012, Electrophoresis.

[25]  G. Whitesides,et al.  Three-dimensional microfluidic devices fabricated in layered paper and tape , 2008, Proceedings of the National Academy of Sciences.

[26]  Fabrication of a microfluidic enzyme reactor utilizing magnetic beads , 2009, Electrophoresis.

[27]  Po Ki Yuen,et al.  SmartBuild-a truly plug-n-play modular microfluidic system. , 2008, Lab on a chip.

[28]  M. Schwarz,et al.  Improved capacitively coupled conductivity detector for capillary electrophoresis , 2002 .

[29]  V. Kuban,et al.  Simultaneous determination of inorganic and organic anions, alkali, alkaline earth and transition metal cations by capillary electrophoresis with contactless conductometric detection , 2002, Electrophoresis.

[30]  Martin A. M. Gijs,et al.  Powder blasting for the realisation of microchips for bio-analytic applications , 2001 .

[31]  S. F. Li,et al.  Conventional capillary electrophoresis in comparison with short-capillary capillary electrophoresis and microfabricated glass chip capillary electrophoresis for the analysis of fluorescein isothiocyanate anti-human immunoglobulin G. , 1997, Journal of chromatography. A.

[32]  Amanda M. Stockton,et al.  Capillary Electrophoresis and Microchip Capillary Electrophoresis , 2013 .

[33]  Lucas Blanes,et al.  Understanding Capacitively Coupled Contactless Conductivity Detection in Capillary and Microchip Electrophoresis. Part 1. Fundamentals , 2005 .

[34]  Charles S Henry,et al.  Comparison of surfactants for dynamic surface modification of poly(dimethylsiloxane) microchips , 2005, Electrophoresis.

[35]  G. Whitesides,et al.  Diagnostics for the developing world: microfluidic paper-based analytical devices. , 2010, Analytical chemistry.

[36]  A. Svatoš,et al.  Chemical modification of polymeric microchip devices. , 2007, Talanta.

[37]  A. Skelley,et al.  Organic amine biomarker detection in the Yungay region of the Atacama Desert with the Urey instrument , 2007 .

[38]  Claudimir Lucio do Lago,et al.  An Oscillometric Detector for Capillary Electrophoresis , 1998 .

[39]  V. Dolnik,et al.  Capillary electrophoresis on microchip , 2000, Electrophoresis.

[40]  Agustín Costa-García,et al.  Poly(methylmethacrylate) and Topas capillary electrophoresis microchip performance with electrochemical detection , 2005, Electrophoresis.

[41]  P. Grodzinski,et al.  Microfabricated polycarbonate CE devices for DNA analysis. , 2001, Analytical chemistry.

[42]  M. Mori,et al.  Capillary ion electrophoresis–capacitively coupled contactless conductivity detection of inorganic cations in human saliva on a polyvinyl alcohol-coated capillary , 2012, Analytical and Bioanalytical Chemistry.

[43]  H. Engelhardt,et al.  Capillary electrophoresis of organic and inorganic cations with indirect UV detection , 1992 .

[44]  P. Sarro,et al.  Fabrication of a glass‐implemented microcapillary electrophoresis device with integrated contactless conductivity detection , 2002, Electrophoresis.

[45]  Gwo-Bin Lee,et al.  Microfabricated plastic chips by hot embossing methods and their applications for DNA separation and detection , 2000, SPIE MOEMS-MEMS.

[46]  Kelliton José Mendonça Francisco,et al.  A compact and high‐resolution version of a capacitively coupled contactless conductivity detector , 2009, Electrophoresis.

[47]  Martin Pumera,et al.  A chip-based capillary electrophoresis-contactless conductivity microsystem for fast measurements of low-explosive ionic components. , 2002, The Analyst.

[48]  Brian N. Johnson,et al.  Flexible casting of modular self-aligning microfluidic assembly blocks. , 2011, Lab on a chip.

[49]  G. Whitesides,et al.  Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane). , 1998, Analytical chemistry.

[50]  A. Karger Separation of DNA sequencing fragments using an automated capillary electrophoresis instrument , 1996, Electrophoresis.

[51]  J. Rossier,et al.  UV Laser Machined Polymer Substrates for the Development of Microdiagnostic Systems. , 1997, Analytical chemistry.

[52]  G. Whitesides,et al.  Poly(dimethylsiloxane) as a material for fabricating microfluidic devices. , 2002, Accounts of chemical research.

[53]  Andreas Neyer,et al.  A new PMMA-microchip device for isotachophoresis with integrated conductivity detector , 2001 .

[54]  W. Heineman,et al.  Study of injection bias in a simple hydrodynamic injection in microchip CE , 2007, Electrophoresis.

[55]  Frank Greer,et al.  Toward total automation of microfluidics for extraterrestial in situ analysis. , 2011, Analytical chemistry.