A Wavelet Based Technique for DFIG Harmonic Reduction in Frequency Domain Based Model of Power System Using Active Filter

This paper presents a technique to reduce the harmonics in wind turbines by using active filter. In this paper, using a frequency based model of power system and using an active filter, the power system harmon ics are decreased and consequently power quality of electrical network will be imp roved. In fact the technique is a combination of wavelet analysis and active filter in a frequency domain based model of the power netwo rk. The results show the powerfulness of the presented method for imp roving the power quality indexes of the electrical network. Vast simulations are performed by PSCAD/ EMTDC software and the results are satisfactory in all scenarios.

[1]  D. Mueller Case studies of harmonic problems, analysis, and solutions on transmission systems , 2007, 2007 9th International Conference on Electrical Power Quality and Utilisation.

[2]  J. Wasilewski,et al.  Harmonic domain modeling of a distribution system using the DIgSILENT PowerFactory software , 2005, 2005 International Conference on Future Power Systems.

[3]  Lingling Fan,et al.  Harmonic Analysis of a DFIG for a Wind Energy Conversion System , 2010, IEEE Transactions on Energy Conversion.

[4]  M. Lindholm,et al.  Harmonic analysis of doubly fed induction generators , 2003, The Fifth International Conference on Power Electronics and Drive Systems, 2003. PEDS 2003..

[5]  Sukumar Mishra,et al.  Detection and classification of power quality disturbances using S-Transform and probabilistic neural network , 2009, 2009 IEEE/PES Power Systems Conference and Exposition.

[6]  F. Choong,et al.  Expert System for Power Quality Disturbance Classifier , 2007, IEEE Transactions on Power Delivery.

[7]  S.M. Brahma,et al.  Distance Relay With Out-of-Step Blocking Function Using Wavelet Transform , 2007, IEEE Transactions on Power Delivery.

[8]  J. Dixon,et al.  A series active power filter scheme for current harmonic compensation , 2008, 2008 IEEE Power Electronics Specialists Conference.

[9]  R. E. Morrison,et al.  Minimisation of interharmonic currents from a current source AC drive by means of a selective DC side active filter , 1995 .

[10]  N. Ertugrul,et al.  Investigation of Effective Automatic Recognition Systems of Power-Quality Events , 2007, IEEE Transactions on Power Delivery.

[11]  M. Kazerani,et al.  Artificial intelligent controller for current source converter-based modular active power filters , 2004, IEEE Transactions on Power Delivery.

[12]  H. Akagi,et al.  A practical approach to harmonic compensation in power systems-series connection of passive and active filters , 1990, Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting.

[13]  John B. Shoven,et al.  I , Edinburgh Medical and Surgical Journal.

[14]  N. Kimura,et al.  Active filter action of inverter exciting induction generator for wind power generation , 2008, 2008 13th International Power Electronics and Motion Control Conference.

[15]  S. Taib,et al.  Performance for passive and active power filter in reducing harmonics in the distribution system , 2004, PECon 2004. Proceedings. National Power and Energy Conference, 2004..

[16]  A. Chilambuchelvan,et al.  Modelling and Analysis of DFIG Wind Turbine Harmonics Generated in Grids , 2010 .

[17]  Takashi Hikihara,et al.  Suppression of harmonic voltage distortion by neural network controlled active filter , 1992, Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting.

[18]  S.A. Papathanassiou,et al.  Harmonic analysis in a power system with wind generation , 2006, IEEE Transactions on Power Delivery.

[19]  Ying-Yi Hong,et al.  Locating Switched Capacitor Using Wavelet Transform and Hybrid Principal Component Analysis Network , 2007, IEEE Transactions on Power Delivery.

[21]  Abdolreza Sheikholeslami,et al.  A New Harmonic Detection Method for Shunt Active Filter Based on Wavelet Transform , 2008 .

[22]  M. Prabhakar,et al.  Harmonic detection using wavelet transform , 2005, Proceedings. 2005 IEEE International Joint Conference on Neural Networks, 2005..

[23]  F. Blaabjerg,et al.  Performance Improvement of Shunt Active Power Filter With Dual Parallel Topology , 2007, IEEE Transactions on Power Electronics.

[24]  K.S. Swarup,et al.  Computationally Efficient Wavelet-Transform-Based Digital Directional Protection for Busbars , 2007, IEEE Transactions on Power Delivery.

[25]  N.I. Elkalashy,et al.  DWT-Based Detection and Transient Power Direction-Based Location of High-Impedance Faults Due to Leaning Trees in Unearthed MV Networks , 2008, IEEE Transactions on Power Delivery.

[26]  T. Tarasiuk,et al.  Hybrid Wavelet–Fourier Method for Harmonics and Harmonic Subgroups Measurement—Case Study , 2007, IEEE Transactions on Power Delivery.