A Wavelet Based Technique for DFIG Harmonic Reduction in Frequency Domain Based Model of Power System Using Active Filter
暂无分享,去创建一个
[1] D. Mueller. Case studies of harmonic problems, analysis, and solutions on transmission systems , 2007, 2007 9th International Conference on Electrical Power Quality and Utilisation.
[2] J. Wasilewski,et al. Harmonic domain modeling of a distribution system using the DIgSILENT PowerFactory software , 2005, 2005 International Conference on Future Power Systems.
[3] Lingling Fan,et al. Harmonic Analysis of a DFIG for a Wind Energy Conversion System , 2010, IEEE Transactions on Energy Conversion.
[4] M. Lindholm,et al. Harmonic analysis of doubly fed induction generators , 2003, The Fifth International Conference on Power Electronics and Drive Systems, 2003. PEDS 2003..
[5] Sukumar Mishra,et al. Detection and classification of power quality disturbances using S-Transform and probabilistic neural network , 2009, 2009 IEEE/PES Power Systems Conference and Exposition.
[6] F. Choong,et al. Expert System for Power Quality Disturbance Classifier , 2007, IEEE Transactions on Power Delivery.
[7] S.M. Brahma,et al. Distance Relay With Out-of-Step Blocking Function Using Wavelet Transform , 2007, IEEE Transactions on Power Delivery.
[8] J. Dixon,et al. A series active power filter scheme for current harmonic compensation , 2008, 2008 IEEE Power Electronics Specialists Conference.
[9] R. E. Morrison,et al. Minimisation of interharmonic currents from a current source AC drive by means of a selective DC side active filter , 1995 .
[10] N. Ertugrul,et al. Investigation of Effective Automatic Recognition Systems of Power-Quality Events , 2007, IEEE Transactions on Power Delivery.
[11] M. Kazerani,et al. Artificial intelligent controller for current source converter-based modular active power filters , 2004, IEEE Transactions on Power Delivery.
[12] H. Akagi,et al. A practical approach to harmonic compensation in power systems-series connection of passive and active filters , 1990, Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting.
[13] John B. Shoven,et al. I , Edinburgh Medical and Surgical Journal.
[14] N. Kimura,et al. Active filter action of inverter exciting induction generator for wind power generation , 2008, 2008 13th International Power Electronics and Motion Control Conference.
[15] S. Taib,et al. Performance for passive and active power filter in reducing harmonics in the distribution system , 2004, PECon 2004. Proceedings. National Power and Energy Conference, 2004..
[16] A. Chilambuchelvan,et al. Modelling and Analysis of DFIG Wind Turbine Harmonics Generated in Grids , 2010 .
[17] Takashi Hikihara,et al. Suppression of harmonic voltage distortion by neural network controlled active filter , 1992, Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting.
[18] S.A. Papathanassiou,et al. Harmonic analysis in a power system with wind generation , 2006, IEEE Transactions on Power Delivery.
[19] Ying-Yi Hong,et al. Locating Switched Capacitor Using Wavelet Transform and Hybrid Principal Component Analysis Network , 2007, IEEE Transactions on Power Delivery.
[21] Abdolreza Sheikholeslami,et al. A New Harmonic Detection Method for Shunt Active Filter Based on Wavelet Transform , 2008 .
[22] M. Prabhakar,et al. Harmonic detection using wavelet transform , 2005, Proceedings. 2005 IEEE International Joint Conference on Neural Networks, 2005..
[23] F. Blaabjerg,et al. Performance Improvement of Shunt Active Power Filter With Dual Parallel Topology , 2007, IEEE Transactions on Power Electronics.
[24] K.S. Swarup,et al. Computationally Efficient Wavelet-Transform-Based Digital Directional Protection for Busbars , 2007, IEEE Transactions on Power Delivery.
[25] N.I. Elkalashy,et al. DWT-Based Detection and Transient Power Direction-Based Location of High-Impedance Faults Due to Leaning Trees in Unearthed MV Networks , 2008, IEEE Transactions on Power Delivery.
[26] T. Tarasiuk,et al. Hybrid Wavelet–Fourier Method for Harmonics and Harmonic Subgroups Measurement—Case Study , 2007, IEEE Transactions on Power Delivery.