A low-friction passive fluid transmission and fluid-tendon soft actuator

We present a passive fluid transmission based on antagonist pairs of rolling diaphragm cylinders. The transmission fluid working volume is completely sealed, forming a closed, passive system, ensuring input-output symmetry and complete backdrivability. Rolling diaphragm-sealed cylinders provide leak-free operation without the stiction of a traditional sliding seal. Fluid pressure preloading allows for bidirectional operation and also serves to preload the gears or belts in the linear-to-rotary output coupler, eliminating system backlash end-to-end. A prototype transmission is built and tested for stiffness, bandwidth, and frictional properties using either air or water as working fluids. Torque transmission is smooth over the entire stroke and stiction is measured to be one percent of full-range torque or less. We also present a tendon-coupled design where the rolling diaphragm is inverted from its normal orientation; this design does not require shaft support bushings, tolerates misalignment, and can be made out of substantially soft materials. Actuator units and a passive transmission are demonstrated using this new soft cylinder design.

[1]  Matthew M. Williamson,et al.  Series elastic actuators , 1995, Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots.

[2]  Clément Gosselin,et al.  On the design of a statically balanced serial robot using remote counterweights , 2013, 2013 IEEE International Conference on Robotics and Automation.

[3]  H. Das,et al.  Dexterity-enhanced telerobotic microsurgery , 1997, 1997 8th International Conference on Advanced Robotics. Proceedings. ICAR'97.

[4]  Hiroshi Kaminaga,et al.  Development of backdrivable hydraulic joint mechanism for knee joint of humanoid robots , 2009, 2009 IEEE International Conference on Robotics and Automation.

[5]  Etienne Burdet,et al.  Dynamics and control of an MRI compatible master-slave system with hydrostatic transmission , 2004, IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004.

[6]  Giulio Sandini,et al.  Robots and Biological Systems: Towards a New Bionics? , 2012, NATO ASI Series.

[7]  Ian W. Hunter,et al.  A comparative analysis of actuator technologies for robotics , 1992 .

[8]  Michael B Binnard,et al.  Design of a small pneumatic walking robot , 1995 .

[9]  Frans C. T. van der Helm,et al.  Bowden Cable Actuator for Force-Feedback Exoskeletons , 2006, 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[10]  Nikolaos G. Tsagarakis,et al.  Development and Control of a ‘Soft-Actuated’ Exoskeleton for Use in Physiotherapy and Training , 2003, Auton. Robots.

[11]  Stephen Paul Buerger,et al.  Stable, high-force, low-impedance robotic actuators for human-interactive machines , 2005 .

[12]  Albert Wang,et al.  Design principles for highly efficient quadrupeds and implementation on the MIT Cheetah robot , 2013, 2013 IEEE International Conference on Robotics and Automation.

[13]  B. Yao,et al.  Modeling of a closed loop cable-conduit transmission system , 2008, 2008 IEEE International Conference on Robotics and Automation.

[14]  J. Kenneth Salisbury,et al.  Mechanical Design for Whole-Arm Manipulation , 1993 .