Phase-based direct average strain estimation for elastography

In this paper, a phase-based direct average strain estimation method is developed. A mathematical model is presented to calculate axial strain directly from the phase of the zero-lag cross-correlation function between the windowed precompression and stretched post-compression analytic signals. Unlike phase-based conventional strain estimators, for which strain is computed from the displacement field, strain in this paper is computed in one step using the secant algorithm by exploiting the direct phase-strain relationship. To maintain strain continuity, instead of using the instantaneous phase of the interrogative window alone, an average phase function is defined using the phases of the neighboring windows with the assumption that the strain is essentially similar in a close physical proximity to the interrogative window. This method accounts for the effect of lateral shift but without requiring a prior estimate of the applied strain. Moreover, the strain can be computed both in the compression and relaxation phases of the applied pressure. The performance of the proposed strain estimator is analyzed in terms of the quality metrics elastographic signal-to-noise ratio (SNRe), elastographic contrast-to-noise ratio (CNRe), and mean structural similarity (MSSIM), using a finite element modeling simulation phantom. The results reveal that the proposed method performs satisfactorily in terms of all the three indices for up to 2.5% applied strain. Comparative results using simulation and experimental phantom data, and in vivo breast data of benign and malignant masses also demonstrate that the strain image quality of our method is better than the other reported techniques.

[1]  L. Pallwein,et al.  Prostate ultrasound—for urologists only? , 2005, Cancer imaging : the official publication of the International Cancer Imaging Society.

[2]  A.H. Gee,et al.  Phase-based ultrasonic deformation estimation , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[3]  Jonathan Ophir,et al.  Elastography: Imaging the elastic properties of soft tissues with ultrasound , 2002, Journal of Medical Ultrasonics.

[4]  K. Boone,et al.  Effect of skin impedance on image quality and variability in electrical impedance tomography: a model study , 1996, Medical and Biological Engineering and Computing.

[5]  Martin J. Yaffe,et al.  Biomechanical 3-D finite element modeling of the human breast using MRI data , 2001, IEEE Transactions on Medical Imaging.

[6]  Tatsuya Higashi,et al.  Cervical lymph node metastases: diagnosis at sonoelastography--initial experience. , 2007, Radiology.

[7]  J. Ophir,et al.  Reduction of Image Noise in Elastography , 1993 .

[8]  Graham M. Treece,et al.  Estimation of Displacement Location for Enhanced Strain Imaging , 2007, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[9]  H. Ermert,et al.  A time-efficient and accurate strain estimation concept for ultrasonic elastography using iterative phase zero estimation , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  Panagiotis Samaras,et al.  Real-time elastography for noninvasive assessment of liver fibrosis in chronic viral hepatitis. , 2007, AJR. American journal of roentgenology.

[11]  C. Merritt,et al.  Toward a standardized breast ultrasound lexicon, BI-RADS: ultrasound. , 2001, Seminars in roentgenology.

[12]  Tomy Varghese,et al.  Adaptive Spectral Strain Estimators for Elastography , 2004, Ultrasonic imaging.

[13]  H. Ermert,et al.  Axial Strain Imaging Using a Local Estimation of the Scaling Factor from RF Ultrasound Signals , 2000, Ultrasonic imaging.

[14]  Tsuyoshi Shiina,et al.  Real time tissue elasticity imaging using the combined autocorrelation method , 2002, Journal of Medical Ultrasonics.

[15]  Ole Gemeinhardt,et al.  Real-time sonoelastography of the cervix: tissue elasticity of the normal and abnormal cervix. , 2007, Academic radiology.

[16]  Eero P. Simoncelli,et al.  Image quality assessment: from error visibility to structural similarity , 2004, IEEE Transactions on Image Processing.

[17]  B. Garra,et al.  Elastography of breast lesions: initial clinical results. , 1997, Radiology.

[18]  Sebastian Wojcinski,et al.  Significant differentiation of focal breast lesions: calculation of strain ratio in breast sonoelastography. , 2010, Academic radiology.

[19]  M. Bilgen,et al.  Deformation models and correlation analysis in elastography. , 1996, The Journal of the Acoustical Society of America.

[20]  J Ophir,et al.  An analysis of elastographic contrast-to-noise ratio. , 1998, Ultrasound in medicine & biology.

[21]  Chris L. de Korte,et al.  Intravascular ultrasound elastography: an overview. , 2002 .

[22]  J. Ophir,et al.  An adaptive strain estimator for elastography , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[23]  T. Krouskop,et al.  Elastic Moduli of Breast and Prostate Tissues under Compression , 1998, Ultrasonic imaging.

[24]  E. M. A. Anas,et al.  Direct mean strain estimation for elastography using nearest-neighbor weighted least-squares approach in the frequency domain. , 2012, Ultrasound in medicine & biology.

[25]  Septimiu E. Salcudean,et al.  Motion Estimation in Ultrasound Images Using Time Domain Cross Correlation With Prior Estimates , 2006, IEEE Transactions on Biomedical Engineering.

[26]  J. Arendt Paper presented at the 10th Nordic-Baltic Conference on Biomedical Imaging: Field: A Program for Simulating Ultrasound Systems , 1996 .

[27]  T. Varghese,et al.  Direct strain estimation in elastography using spectral cross-correlation. , 2000, Ultrasound in medicine & biology.

[28]  J. Ophir,et al.  A new elastographic method for estimation and imaging of lateral displacements, lateral strains, corrected axial strains and Poisson's ratios in tissues. , 1998, Ultrasound in medicine & biology.

[29]  A. Pesavento,et al.  Time-efficient and exact algorithms for adaptive temporal stretching and 2D-correlation for elastographic imaging using phase information , 1998, 1998 IEEE Ultrasonics Symposium. Proceedings (Cat. No. 98CH36102).

[30]  F. Kallel,et al.  A Least-Squares Strain Estimator for Elastography , 1997, Ultrasonic imaging.

[31]  A. Pinchera,et al.  Elastography: new developments in ultrasound for predicting malignancy in thyroid nodules. , 2007, The Journal of clinical endocrinology and metabolism.

[32]  H. Ermert,et al.  A new system for the acquisition of ultrasonic multicompression strain images of the human prostate in vivo , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[33]  J. Ophir,et al.  Elastography: Elasticity Imaging Using Ultrasound with Application to Muscle and Breast in Vivo , 1993, Ultrasonic imaging.

[34]  Mohammad Arafat Hussain,et al.  Robust Strain-Estimation Algorithm Using Combined Radiofrequency and Envelope Cross-Correlation with Diffusion Filtering , 2012, Ultrasonic imaging.

[35]  A. Gefen,et al.  Mechanics of the normal woman's breast. , 2007, Technology and health care : official journal of the European Society for Engineering and Medicine.

[36]  J. Ophir,et al.  Elastography: A Quantitative Method for Imaging the Elasticity of Biological Tissues , 1991, Ultrasonic imaging.

[37]  Gregory D. Hager,et al.  Real-Time Regularized Ultrasound Elastography , 2011, IEEE Transactions on Medical Imaging.

[38]  K. Togashi,et al.  Thyroid gland tumor diagnosis at US elastography. , 2005, Radiology.