A Steady-Hand Robotic System for Microsurgical Augmentation

This paper reports the development of a robotic system designed to extend a human’s ability to perform small-scale (sub-millimeter) manipulation tasks requiring human judgement, sensory integration and hand-eye coordination. Our novel approach, which we call “steady hand” micromanipulation, is for tools to be held simultaneously both by the operator’s hand and a specially designed actively controlled robot arm. The robot’s controller senses forces exerted by the operator on the tool and by the tool on the environment, and uses this information in various control modes to provide smooth, tremor-free precise positional control and force scaling. Our goal is to develop a manipulation system with the precision and sensitivity of a machine, but with the manipulative transparency and immediacy of handheld tools for tasks characterized by compliant or semi-rigid contacts with the environment.

[1]  S. Sakakibara A two-armed intelligent robot assembles mini robots automatically , 1996, Proceedings of the 1996 IEEE IECON. 22nd International Conference on Industrial Electronics, Control, and Instrumentation.

[2]  C. Riviere,et al.  Intraoperative tremor monitoring for vitreoretinal microsurgery. , 2000, Studies in health technology and informatics.

[3]  Septimiu E. Salcudean,et al.  Performance measurement in scaled teleoperation for microsurgery , 1997, CVRMed.

[4]  Eugene de Juan,et al.  In-vivo microscopy using gradient index of refraction (GRIN) lens endoscopy , 1999, Photonics West - Biomedical Optics.

[5]  Hari Das,et al.  Development of a new high-dexterity manipulator for robot-assisted microsurgery , 1995, Other Conferences.

[6]  James H. Anderson,et al.  A robotic system for percutaneous renal access. , 1997, The Journal of urology.

[7]  Russell H. Taylor,et al.  An efficient needle injection technique and radiological guidance method for percutaneous procedures , 1997, CVRMed.

[8]  Thomas B. Sheridan Teleoperation, Telerobotics, and Telepresence: A Progress Report , 1992 .

[9]  Daniel E. Koditschek,et al.  Comparative experiments with a new adaptive controller for robot arms , 1991, Proceedings. 1991 IEEE International Conference on Robotics and Automation.

[10]  H. Kazerooni Human/robot interaction via the transfer of power and information signals. I. Dynamics and control analysis , 1989, Proceedings, 1989 International Conference on Robotics and Automation.

[11]  Russell H. Taylor,et al.  A Modular Surgical Robotic System for Image Guided Percutaneous Procedures , 1998, MICCAI.

[12]  E. de Juan,et al.  Quantitative measurement of the effects of caffeine and propranolol on surgeon hand tremor. , 1997, Archives of ophthalmology.

[13]  Kazuo Tanie,et al.  Discrete-event-based planning and control of telerobotic part-mating process with communication delay and geometric uncertainty , 1995, Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots.

[14]  S. Huang,et al.  Cost effectiveness of electrohydraulic lithotripsy v Candela pulsed-dye laser in management of the distal ureteral stone. , 1998, Journal of endourology.

[15]  Mamoru Mitsuishi,et al.  Dexterity enhancement for a tele-micro-surgery system with multiple macro-micro co-located operation point manipulators and understanding of the operator's intention , 1997, CVRMed.

[16]  Russell H. Taylor,et al.  Comparison of two manipulator designs for laparoscopic surgery , 1995, Other Conferences.

[17]  Russell H. Taylor,et al.  Experiments with a steady hand robot in constrained compliant motion and path following , 1999, 8th IEEE International Workshop on Robot and Human Interaction. RO-MAN '99 (Cat. No.99TH8483).

[18]  Brian L. Davies,et al.  Experiences with robotic systems for knee surgery , 1997, CVRMed.

[19]  Russell H. Taylor,et al.  A telerobotic assistant for laparoscopic surgery , 1995 .

[20]  Russell H. Taylor,et al.  A remote center of motion robotic arm for computer assisted surgery , 1996, Robotica.

[21]  Michael A. Peshkin,et al.  The use of localizers, robots and synergistic devices in CAS , 1997, CVRMed.

[22]  Homayoon Kazerooni,et al.  Human/robot interaction via the transfer of power and information signals , 1989, Images of the Twenty-First Century. Proceedings of the Annual International Engineering in Medicine and Biology Society,.

[23]  Cameron N. Riviere,et al.  Augmenting the human-machine interface: improving manual accuracy , 1997, Proceedings of International Conference on Robotics and Automation.

[24]  Janez Funda,et al.  Optimal motion control for teleoperated surgical robots , 1993, Other Conferences.

[25]  Darrell K. Root,et al.  Space Robotics: Dynamics and Control , 1996 .

[26]  Russell H. Taylor,et al.  Robot-assisted minimally invasive neurosurgical procedures: first experimental experience , 1997, CVRMed.

[27]  R. D. Hibberd,et al.  Robot assisted knee surgery , 1995 .

[28]  Tzyh Jong Tarn,et al.  Fusion of human and machine intelligence for telerobotic systems , 1995, Proceedings of 1995 IEEE International Conference on Robotics and Automation.

[29]  C. Pournaras,et al.  New ocular micromanipulator for measurements of retinal and vitreous physiologic parameters in the mammalian eye. , 1991, Experimental eye research.

[30]  A. Guerrouad,et al.  SMOS: stereotaxical microtelemanipulator for ocular surgery , 1989, Images of the Twenty-First Century. Proceedings of the Annual International Engineering in Medicine and Biology Society,.

[31]  Suguru Arimoto,et al.  Adaptive model-based hybrid control of geometrically constrained robot arms , 1997, IEEE Trans. Robotics Autom..

[32]  Xiaoping Yun,et al.  Coordinated task execution of a human and a mobile manipulator , 1996, Proceedings of IEEE International Conference on Robotics and Automation.

[33]  Robert D. Howe,et al.  Tactile Display of High-Frequency Information in Teleoperation and Virtual Environments. , 1995 .

[34]  Yorktown Heights,et al.  An Image-directed Robotic System for Precise Orthopaedic Surgery , 1990 .

[35]  Cameron N. Riviere,et al.  Microscale Tracking of Surgical Instrument Motion , 1999, MICCAI.

[36]  D. Stoianovici,et al.  Stereotactic mechanical percutaneous renal access. , 1998, Journal of endourology.

[37]  Suguru Arimoto,et al.  Visual control of autonomous mobile robot based on self-organizing model for pattern learning , 1988, J. Field Robotics.

[38]  Jocelyne Troccaz,et al.  CVRMed-MRCAS'97 , 1997, Lecture Notes in Computer Science.

[39]  Russell H. Taylor,et al.  Performance of Robotic Augmentation in Microsurgery-Scale Motions , 1999, MICCAI.

[40]  Hajime Morikawa,et al.  Ground experiment system for space robots based on predictive bilateral control , 1996, Proceedings of IEEE International Conference on Robotics and Automation.

[41]  Reid G. Simmons,et al.  Performance of a six-legged planetary rover: power, positioning, and autonomous walking , 1992, Proceedings 1992 IEEE International Conference on Robotics and Automation.

[42]  Cameron N. Riviere,et al.  Modeling and canceling tremor in human-machine interfaces , 1996 .

[43]  Robert D. Howe,et al.  Tactile Display of Vibratory Information in Teleoperation and Virtual Environments , 1995, Presence: Teleoperators & Virtual Environments.

[44]  W. M. Grant,et al.  Outflow facility studies in the perfused human ocular anterior segment. , 1991, Experimental eye research.

[45]  P J Hunter,et al.  Ophthalmic microsurgical robot and associated virtual environment. , 1995, Computers in biology and medicine.