A multi-beam x-ray imaging system based on carbon nanotube field emitters

In this study, we report a multi-beam x-ray imaging system that can generate a scanning x-ray beam to image an object from multiple projection angles without mechanical motion. The key part of this imaging system is a multi-beam field emission x-ray (MBFEX) source which comprises a linear array of gated electron emitting pixels. The pixels are individually addressable via a MOSFET (metal-oxide-semiconductor field effect transistor) based electronic circuit. The device can provide a tube current of 0.1-1 mA at 40 kVp with less than 300 μm focal spot size from each of the emitting pixels. Multilayer images of different phantoms were reconstructed to demonstrate its potential applications in tomographic imaging. Since no mechanical motion is needed and the electronic switching time is generally negligible the MBFEX system has the potential to simplify the system design and lead to a fast data acquisition for tomographic imaging.

[1]  C. Morgan,et al.  Basic Principles of Computed Tomography , 1983 .

[2]  Yuan Cheng,et al.  Fabrication and electron field emission properties of carbon nanotube films by electrophoretic deposition , 2001 .

[3]  E. Ritenour,et al.  Medical Imaging Physics , 1992 .

[4]  Benjamin M. W. Tsui,et al.  Principles of Medical Imaging , 1992 .

[5]  I. I. Rushakov,et al.  Computed Tomography , 2019, Compendium of Biomedical Instrumentation.

[6]  Otto Zhou,et al.  Stationary scanning x-ray source based on carbon nanotube field emitters , 2005 .

[7]  G. Hounsfield Computerized transverse axial scanning (tomography): Part I. Description of system. 1973. , 1973, The British journal of radiology.

[8]  G. Hounsfield Computerized transverse axial scanning (tomography). 1. Description of system. , 1973, The British journal of radiology.

[9]  James T Dobbins,et al.  Digital x-ray tomosynthesis: current state of the art and clinical potential. , 2003, Physics in medicine and biology.

[10]  E Klotz,et al.  Coronary angiography with flashing tomosynthesis. , 1985, European heart journal.

[11]  E Klotz,et al.  First clinical results with digital flashing tomosynthesis in coronary angiography. , 1985, European heart journal.

[12]  R. A. Brooks,et al.  Principles of computer assisted tomography (CAT) in radiographic and radioisotopic imaging , 1976, Physics in medicine and biology.

[13]  D. Vanderstraeten,et al.  Three-dimensional x-ray laminography as a tool for detection and characterization of BGA package defects , 2002 .

[14]  A. Cormack Reconstruction of densities from their projections, with applications in radiological physics. , 1973, Physics in medicine and biology.

[15]  E Klotz,et al.  Work in progress. Flashing tomosynthesis: a tomographic technique for quantitative coronary angiography. , 1982, Radiology.

[16]  Yuan Cheng,et al.  A nanotube-based field emission x-ray source for microcomputed tomography , 2005 .

[17]  E. Klotz,et al.  Flashing tomosynthesis — A new tomographic method , 1980, Neuroradiology.

[18]  John A. Rumberger,et al.  Ultrafast Computed Tomography in Cardiac Imaging: Principles and Practice , 1992 .