Transient Analysis of Symmetrical Networks by the Method of Symmetrical Components

The canonical equations of a general, linear, bilateral symmetrical network of n meshes on which are impressed Laplacian transformation. The transformed equations are then subjected to a symmetrical component transformation. By the use of these transformations the transient behavior of an n mesh symmetrical network subject to impressed arbitrary voltages and initial currents and charges is readily obtained. The solution of the usual determinantal equation is avoided.

[1]  Norbert Wiener,et al.  The operational calculus , 1926 .

[2]  L. A. Pipes,et al.  Matrices in Engineering , 1937, Transactions of the American Institute of Electrical Engineers.

[3]  Louis A. Pipes,et al.  The Operational Calculus. I , 1939 .