The squeaking hip: a phenomenon of ceramic-on-ceramic total hip arthroplasty.

BACKGROUND Early reports on modern ceramic-on-ceramic total hip replacements have demonstrated excellent clinical and radiographic results with few cases of catastrophic failure, which, in the case of earlier designs, often had been caused by implant fracture. Several reports, however, have noted the presence of audible squeaking. The purpose of the present study was to determine the incidence of squeaking in association with the use of this bearing couple. METHODS During the period from March 2003 to May 2005, three surgeons performed 159 total hip arthroplasties in 143 patients with use of a ceramic-on-ceramic bearing. One hundred and forty-nine hips (131 patients) were available for review after at least one year of follow-up. These patients were followed prospectively with use of the modified Hospital for Special Surgery hip score and a patient-administered questionnaire. Additionally, a control group of sixty hips (forty-eight patients) with a metal-on-polyethylene bearing was matched to the ceramic group on the basis of age, sex, and body mass index to compare the incidence of squeaking and other noises. Radiographic evaluations were performed according to previously established criteria. RESULTS Fourteen (10.7%) of 131 patients described an audible squeak during normal activities. However, squeaking was reproducible clinically in only four patients, and only one patient complained of squeaking before being presented with the questionnaire. The average Hospital for Special Surgery score improved from 19.8 preoperatively to 38.4 at the time of the latest follow-up, indicating excellent clinical results. Ninety-five percent of the patients had a satisfaction score of > or =8 of 10. Three hips dislocated. One of those three hips squeaked and was revised because of recurrent dislocations. One patient was considering revision because of squeaking. In the matched metal-on-polyethylene cohort, there were no cases of squeaking. CONCLUSIONS The squeaking hip is a phenomenon that is unique to total hip replacements with hard-on-hard bearings. The incidence of squeaking in association with ceramic-on-ceramic bearings may be higher than previously reported as <1% of the patients in the present study reported this finding before being queried. The causes and implications of squeaking are yet to be determined. The use of hard-on-hard bearings offers many advantages in terms of wear reduction, especially for young and active patients. Nonetheless, patients considering ceramic-on-ceramic bearings should be counseled with regard to this phenomenon.

[1]  Kate Sutton,et al.  The role of stripe wear in causing acoustic emissions from alumina ceramic-on-ceramic bearings. , 2007, The Journal of arthroplasty.

[2]  G Willmann,et al.  Mismatched wear couple zirconium oxide and aluminum oxide in total hip arthroplasty. , 2001, The Journal of arthroplasty.

[3]  M. Ritter,et al.  The effect of retropatellar fat pad excision on patellar tendon contracture and functional outcomes after total knee arthroplasty. , 2007, The Journal of arthroplasty.

[4]  M. Boehler,et al.  Long-term results of uncemented alumina acetabular implants. , 1994, The Journal of bone and joint surgery. British volume.

[5]  A. Carr,et al.  Outcomes evaluation in orthopaedics. , 2001, The Journal of bone and joint surgery. British volume.

[6]  F. Sim Surgical Exposures in Orthopaedics: The Anatomic Approach , 1985 .

[7]  P. Boutin,et al.  [Total arthroplasty of the hip by fritted aluminum prosthesis. Experimental study and 1st clinical applications]. , 1972, Revue de chirurgie orthopedique et reparatrice de l'appareil moteur.

[8]  L. Sedel,et al.  Ceramics in orthopaedics. , 2000, The Journal of bone and joint surgery. British volume.

[9]  B. Bierbaum,et al.  Ceramic-on-Ceramic Bearings in Total Hip Arthroplasty , 2002, Clinical orthopaedics and related research.

[10]  O. Holubowycz,et al.  Comparison of Patient and Doctor Responses to a Total Hip Arthroplasty Clinical Evaluation Questionnaire , 2002, The Journal of bone and joint surgery. American volume.

[11]  L. Sedel,et al.  Prevention of Wear and Osteolysis: Alumina-on-Alumina Bearing , 2001, Clinical orthopaedics and related research.

[12]  A. Roquancourt,et al.  The use of dense alumina-alumina ceramic combination in total hip replacement. , 1988, Journal of biomedical materials research.

[13]  R. Trousdale,et al.  Fracture of a Ceramic Femoral Head after a Revision Operation. A Case Report* , 1997, The Journal of bone and joint surgery. American volume.

[14]  J. Jacobs,et al.  Alternative bearing surfaces in total joint replacement , 1998 .

[15]  B. W. Schreurs,et al.  High Incidence of Squeaking in THAs with Alumina Ceramic-on-ceramic Bearings , 2008, Clinical orthopaedics and related research.

[16]  P. D. Wilson,et al.  Total hip replacement with fixation by acrylic cement. A preliminary study of 100 consecutive McKee-Farrar prosthetic replacements. , 1972, The Journal of bone and joint surgery. American volume.

[17]  H. Skinner,et al.  Concerns about ceramics in THA. , 2004, Clinical orthopaedics and related research.

[18]  V. Pathania Surgical Exposures in Orthopaedics : The Anatomic Approach , 2001 .

[19]  W. Capello,et al.  A Titanium-encased Alumina Ceramic Bearing for Total Hip Arthroplasty: 3- to 5-Year Results , 2005, Clinical orthopaedics and related research.

[20]  C. Ranawat,et al.  A self-administered hip-rating questionnaire for the assessment of outcome after total hip replacement. , 1992, The Journal of bone and joint surgery. American volume.

[21]  S Berdia,et al.  Determination of Polyethylene Wear in Total Hip Replacements with Use of Digital Radiographs* , 1997, The Journal of bone and joint surgery. American volume.

[22]  U. Wyss,et al.  Clinical Wear Performance of Metal-on-Metal Hip Arthroplasties , 1998 .

[23]  S. MacDonald,et al.  Metal-on-metal total hip arthroplasty: the concerns. , 2004, Clinical orthopaedics and related research.

[24]  J. Garino Modern Ceramic-on-Ceramic Total Hip Systems in the United States: Early Results , 2000, Clinical orthopaedics and related research.

[25]  I. Clarke,et al.  Squeaking in a Ceramic on Ceramic Total Hip , 2003 .

[26]  S. Kurtz,et al.  The noisy ceramic hip: is component malpositioning the cause? , 2008, The Journal of arthroplasty.

[27]  I. Clarke,et al.  Role of ceramic implants. Design and clinical success with total hip prosthetic ceramic-to-ceramic bearings. , 1992, Clinical orthopaedics and related research.

[28]  S. Jaglal,et al.  The effect of hospital type and surgical delay on mortality after surgery for hip fracture. , 2005, The Journal of bone and joint surgery. British volume.

[29]  W. Capello,et al.  Alumina Ceramic Bearings for Total Hip Arthroplasty: Five-year Results of a Prospective Randomized Study , 2005, Clinical orthopaedics and related research.

[30]  L. Sedel,et al.  Evolution of alumina-on-alumina implants: a review. , 2000, Clinical orthopaedics and related research.

[31]  J. Jacobs,et al.  Alternate bearing surfaces in total joint arthroplasty: biologic considerations. , 2000, Clinical orthopaedics and related research.

[32]  R. K. Peterson,et al.  The spinoglenoid ligament. Anatomy, morphology, and histological findings. , 2005, The Journal of bone and joint surgery. American volume.