Ultrasensitive detection technique for tunable diode laser spectrometers: application to detection of NO2 and H2O

Recent advances in room-temperature tunable diode lasers and ultrasensitive electronic noise quieting detection techniques now enable a new generation of compact, optoelectronic, ultrasensitive trace gas sensors. These advances are key to producing sensors capable of routine and extended field use. We achieve near shot noise-limited signal detection using a novel, balanced ratiometric detector (BRD) which permits measurements of absorbances of 1:106. High sensitivity is achieved by coupling this technology with an extended optical pathlength. The BRD is characterized by a wide linear dynamic range. A 10 Hz measurement rate enables ground level flux measurements or airborne concentration measurements. We will present an overview of two applications of our ultrasensitive detection technology to in situ atmospheric sensing. The first sensor is being developed to monitor boundary layer NO2 fluxes. This sensor operates at 670 nm, utilizes an open multipass optical cell, and has a sub-ppbv detection sensitivity. The second sensor is an airborne, near IR diode laser hygrometer. The sensor uses an in-situ air measurement probe housing a 50 cm, open optical path to circumvent problems inherent in extractive sampling. The sensor is capable of measuring water vapor throughout the troposphere and has a sensitivity of 0.5 ppmv at the tropopause.

[1]  R. Zare,et al.  Spectral atlas of nitrogen dioxide, 5530 to 6480 Å , 1978 .

[2]  W. Lenth,et al.  Sensitive detection of NO2 using high‐frequency heterodyne spectroscopy with a GaAlAs diode laser , 1985 .

[3]  V. M. Devi,et al.  THE HITRAN MOLECULAR DATABASE: EDITIONS OF 1991 AND 1992 , 1992 .

[4]  B K Garside,et al.  Sensitivity limits of a tunable diode laser spectrometer, with application to the detection of NO(2) at the 100-ppt level. , 1980, Applied optics.

[5]  J. Burrows,et al.  Absorption cross-sections of NO2 in the UV and visible region (200 – 700 nm) at 298 K , 1987 .

[6]  Philip C. D. Hobbs,et al.  Double-beam laser absorption spectroscopy: shot noise-limited performance at baseband with a novel electronic noise canceler , 1991, Photonics West - Lasers and Applications in Science and Engineering.

[7]  W. Kessler,et al.  Ultrasensitive dual-beam absorption and gain spectroscopy: applications for near-infrared and visible diode laser sensors. , 1995, Applied optics.

[8]  R. May,et al.  Aircraft (ER-2) laser infrared absorption spectrometer (ALIAS) for in-situ stratospheric measurements of HCI, N(2)O, CH(4), NO(2), and HNO(3). , 1994, Applied optics.

[9]  L. W. Carr,et al.  Design of an open path near-infrared diode laser sensor: application to oxygen, water, and carbon dioxide vapor detection. , 1994, Applied optics.

[10]  M. Allen,et al.  Ultrasensitive, visible tunable diode laser detection of NO(2). , 1996, Applied optics.

[11]  J. A. Silver,et al.  Airborne measurements of humidity using a single-mode Pb-salt diode laser. , 1987, Applied optics.

[12]  Philip C. D. Hobbs,et al.  Shot noise limited optical measurements at baseband with noisy lasers (proceedings Only) , 1991, Other Conferences.

[13]  J. A. Silver,et al.  Near‐infrared diode laser airborne hygrometer , 1994 .