Suitability of miniature inductively coupled RF coils as MR-visible markers for clinical purposes.

PURPOSE MR-visible markers have already been used for various purposes such as image registration, motion detection, and device tracking. Inductively coupled RF (ICRF) coils, in particular, provide a high contrast and do not require connecting wires to the scanner, which makes their application highly flexible and safe. This work aims to thoroughly characterize the MR signals of such ICRF markers under various conditions with a special emphasis on fully automatic detection. METHODS The small markers consisted of a solenoid coil that was wound around a glass tube containing the MR signal source and tuned to the resonance frequency of a 1.5 T MRI. Marker imaging was performed with a spoiled gradient echo sequence (FLASH) and a balanced steady-state free precession (SSFP) sequence (TrueFISP) in three standard projections. The signal intensities of the markers were recorded for both pulse sequences, three source materials (tap water, distilled water, and contrast agent solution), different flip angles and coil alignments with respect to the B(0) direction as well as for different marker positions in the entire imaging volume (field of view, FOV). Heating of the ICRF coils was measured during 10-min RF expositions to three conventional pulse sequences. Clinical utility of the markers was assessed from their performance in computer-aided detection and in defining double oblique scan planes. RESULTS For almost the entire FOV (±215 mm) and an estimated 82% of all possible RF coil alignments with respect to B(0), the ICRF markers generated clearly visible MR signals and could be reliably localized over a large range of flip angles, in particular with the TrueFISP sequence (0.3°-4.0°). Generally, TrueFISP provided a higher marker contrast than FLASH. RF exposition caused a moderate heating (≤5 °C) of the ICRF coils only. CONCLUSIONS Small ICRF coils, imaged at low flip angles with a balanced SSFP sequence showed an excellent performance under a variety of experimental conditions and therefore make for a reliable, compact, flexible, and relatively safe marker for clinical use.

[1]  R Lufkin,et al.  A technique for MR-guided needle placement. , 1988, AJR. American journal of roentgenology.

[2]  G A Coutts,et al.  Integrated and interactive position tracking and imaging of interventional tools and internal devices using small fiducial receiver coils , 1998, Magnetic resonance in medicine.

[3]  Rebecca Fahrig,et al.  Pair of resonant fiducial markers for localization of endovascular catheters at all catheter orientations , 2003, Journal of magnetic resonance imaging : JMRI.

[4]  A Shankaranarayanan,et al.  A method for fast 3D tracking using tuned fiducial markers and a limited projection reconstruction FISP (LPR‐FISP) sequence , 2001, Journal of magnetic resonance imaging : JMRI.

[5]  C. C. Parkera,et al.  Magnetic resonance imaging in the radiation treatment planning of localized prostate cancer using intra-prostatic fiducial markers for computed tomography co-registration , 2003 .

[6]  Sebastian Meister,et al.  Improved multimodality imaging using alginate molding in xenograft tumor models , 2010, Journal of magnetic resonance imaging : JMRI.

[7]  Michael Lamperth,et al.  Sub-pixel localisation of passive micro-coil fiducial markers in interventional MRI , 2009, Magnetic Resonance Materials in Physics, Biology and Medicine.

[8]  M A Viergever,et al.  MR-guided endovascular interventions: susceptibility-based catheter and near-real-time imaging technique. , 1997, Radiology.

[9]  Wolfgang Kainz,et al.  MR heating tests of MR critical implants , 2007, Journal of magnetic resonance imaging : JMRI.

[10]  Ergin Atalar,et al.  A catheter tracking method using reverse polarization for MR‐guided interventions , 2007, Magnetic resonance in medicine.

[11]  M. Bock,et al.  Automatic passive tracking of an endorectal prostate biopsy device using phase‐only cross‐correlation , 2008, Magnetic resonance in medicine.

[12]  Sascha Krueger,et al.  Prospective real‐time correction for arbitrary head motion using active markers , 2009, Magnetic resonance in medicine.

[13]  K. Scheffler,et al.  Principles and applications of balanced SSFP techniques , 2003, European Radiology.

[14]  Deming Wang,et al.  Geometric distortion in clinical MRI systems Part I: evaluation using a 3D phantom. , 2004, Magnetic resonance imaging.

[15]  Robert Trampel,et al.  Navigation concepts for MR image‐guided interventions , 2008, Journal of magnetic resonance imaging : JMRI.

[16]  Thomas Kahn,et al.  Flexible add‐on solution for MR image‐guided interventions in a closed‐bore scanner environment , 2010, Magnetic resonance in medicine.

[17]  Robert Trampel,et al.  Method for automatic localization of MR‐visible markers using morphological image processing and conventional pulse sequences: Feasibility for image‐guided procedures , 2007, Journal of magnetic resonance imaging : JMRI.

[18]  R. Lederman,et al.  Robust automatic rigid registration of MRI and X-ray using external fiducial markers for XFM-guided interventional procedures. , 2010, Medical physics.

[19]  C J Bakker,et al.  Heating Around Intravascular Guidewires by Resonating RF Waves , 2000, Journal of magnetic resonance imaging : JMRI.

[20]  E. Yorke,et al.  A new fiducial alignment system to overlay abdominal computed tomography or magnetic resonance anatomical images with radiolabeled antibody single‐photon emission computed tomographic scans , 1994, Cancer.

[21]  Christopher Nimsky,et al.  Application Accuracy of Automatic Registration in Frameless Stereotaxy , 2006, Stereotactic and Functional Neurosurgery.

[22]  I R Young,et al.  Tuned fiducial markers to identify body locations with minimal perturbation of tissue magnetization , 1996, Magnetic resonance in medicine.

[23]  Michael O Zenge,et al.  Interventional magnetic resonance angiography with no strings attached: Wireless active catheter visualization , 2005, Magnetic resonance in medicine.

[24]  David M. Doddrell,et al.  Geometric distortion in clinical MRI systems Part II: correction using a 3D phantom. , 2004, Magnetic resonance imaging.

[25]  T Haycocks,et al.  Magnetic resonance imaging in the radiation treatment planning of localized prostate cancer using intra-prostatic fiducial markers for computed tomography co-registration. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[26]  Frank G Shellock,et al.  Comments on MR heating tests of critical implants , 2007, Journal of magnetic resonance imaging : JMRI.

[27]  Roland Ladurner,et al.  Assessment of colonic transit time using MRI: a feasibility study , 2007, European Radiology.

[28]  Mehmet Z. Unlu,et al.  Computerized method for nonrigid MR-to-PET breast-image registration , 2010, Comput. Biol. Medicine.

[29]  Wolfhard Semmler,et al.  MR‐guided intravascular procedures: Real‐time parameter control and automated slice positioning with active tracking coils , 2004, Journal of magnetic resonance imaging : JMRI.