EMG AND MUSCLE FORCE - AN INTRODUCTION

Abstract This paper is intended as an introduction to those methods of processing and presentation of the electromyogram (EMG) that give information about the muscle force or work in human movement. The physiological origin of the EMG is treated briefly, followed by a discussion of EMG recording and preprocessing: electrodes, preamplifier, rectifier, smoothing filter. Special attention is given to the prevention and suppression of interferences. The relation between EMG, muscle length and muscle force is explained on the basis of a three-component Hill muscle model. With this background, some possibilities on how to obtain quantitative information about muscle force, work and energy consumption in various categories of movement are summed up and discussed. Some possible applications in human movement studies are suggested.

[1]  F. Bosman,et al.  Reflex sensitivity of human jaw-closing muscles during the silent period following a jaw jerk. , 1983, Archives of oral biology.

[2]  J. van den Berg,et al.  EMG to force processing I: An electrical analogue of the Hill muscle model. , 1981, Journal of biomechanics.

[3]  J. van den Berg,et al.  Calf muscle moment, work and efficiency in level walking; role of series elasticity. , 1983, Journal of biomechanics.

[4]  J. van den Berg,et al.  EMG to force processing III: Estimation of model parameters for the human triceps surae muscle and assessment of the accuracy by means of a torque plate. , 1981, Journal of biomechanics.

[5]  A. R. Lind,et al.  Evaluation of amplitude and frequency components of the surface EMG as an index of muscle fatigue. , 1982, Ergonomics.

[6]  J. van den Berg,et al.  Linearity between the weighted sum of the EMGs of the human triceps surae and the total torque. , 1977, Journal of biomechanics.

[7]  A. Huxley,et al.  The variation in isometric tension with sarcomere length in vertebrate muscle fibres , 1966, The Journal of physiology.

[8]  A. Cappozzo,et al.  The interplay of muscular and external forces in human ambulation. , 1976, Journal of biomechanics.

[9]  G. Gottlieb,et al.  Dynamic relationship between isometric muscle tension and the electromyogram in man. , 1971, Journal of applied physiology.

[10]  Julie Whelan,et al.  Human muscle fatigue: physiological mechanisms. , 1981, Ciba Foundation symposium.

[11]  Herbert Hatze,et al.  Myocybernetic control models of skeletal muscle : characteristics and applications , 1981 .

[12]  Lambert Schomaker,et al.  Motor Unit Firing Rate During Static Contraction Indicated by the Surface EMG Power Spectrum , 1983, IEEE Transactions on Biomedical Engineering.

[13]  T. Moritani,et al.  Reexamination of the relationship between the surface integrated electromyogram (IEMG) and force of isometric contraction. , 1978, American journal of physical medicine.

[14]  S. Bouisset,et al.  Integrated electromyographical activity and muscle work. , 1973, Journal of applied physiology.

[15]  J M Halbertsma,et al.  On the processing of electromyograms for computer analysis. , 1981, Journal of biomechanics.

[16]  J. Kreifeldt Signal versus noise characteristics of filtered EMG used as a control source. , 1971, IEEE transactions on bio-medical engineering.

[17]  O. Lippold,et al.  The relation between force, velocity and integrated electrical activity in human muscles , 1954, The Journal of physiology.

[18]  J C Cnockaert,et al.  Relative contribution of individual muscles to the isometric contraction of a muscular group. , 1975, Journal of biomechanics.

[19]  J. Berg,et al.  Microphonic Effect of the Larynx , 1957, Nature.

[20]  J. J. Bosch,et al.  Jaw muscle EMG-activity and static loading of the mandible. , 1978 .

[21]  J. van den Berg,et al.  EMG to force processing IV: Eccentric-concentric contractions on a spring-flywheel set up. , 1981, Journal of biomechanics.

[22]  A. Hill Production and absorption of work by muscle. , 1960, Science.

[23]  S. Bouisset EMG and Muscle Force in Normal Motor Activities , 1973 .

[24]  F. Bonde-petersen,et al.  Integrated electromyography of quadriceps femoris muscle at different exercise intensities. , 1974, Journal of applied physiology.

[25]  B Bigland-Ritchie,et al.  Integrated EMG and oxygen uptake during dynamic contractions of human muscles. , 1974, Journal of applied physiology.

[26]  Inman Vt,et al.  Comparison of electrical activity and duration of tension in the human rectus femoris muscle. , 1976 .

[27]  G. E. Goslow,et al.  Electrical activity and relative length changes of dog limb muscles as a function of speed and gait. , 1981, The Journal of experimental biology.

[28]  A. Noordergraaf,et al.  Voluntary skeletal muscles: a unifying theory on the relationship of their electrical and mechanical activities. , 1975, Archives of physical medicine and rehabilitation.

[29]  J. Mansour,et al.  The passive elastic moment at the hip. , 1982, Journal of biomechanics.

[30]  Isak Gath,et al.  Measurements of the Uptake Area of Small-Size Electromyographic Electrodes , 1979, IEEE Transactions on Biomedical Engineering.

[31]  R. H. Rozendal,et al.  Human kinesiological electromyography: Some methodological problems , 1982 .

[32]  A. Schultz,et al.  Analysis and measurement of the loads on the lumbar spine during work at a table. , 1980, Journal of biomechanics.

[33]  M I Harba,et al.  Optimizing the acquisition and processing of surface electromyographic signals. , 1981, Journal of biomedical engineering.

[34]  B Bigland-Ritchie,et al.  Integrated electromyogram and oxygen uptake during positive and negative work. , 1976, The Journal of physiology.

[35]  John V. Basmajian,et al.  Computers in electromyography , 1975 .

[36]  B Bigland-Ritchie,et al.  EMG/FORCE RELATIONS AND FATIGUE OF HUMAN VOLUNTARY CONTRACTIONS , 1981, Exercise and sport sciences reviews.

[37]  Carlo J. De Luca,et al.  Physiology and Mathematics of Myoelectric Signals , 1979 .

[38]  J. van den Berg,et al.  EMG to force processing II: Estimation of parameters of the Hill muscle model for the human triceps surae by means of a calfergometer. , 1981, Journal of biomechanics.

[39]  J Verroust,et al.  The determination of motor units characteristics from the low frequency electromyographic power spectra. , 1979, Electromyography and clinical neurophysiology.

[40]  A. Thorstensson,et al.  Lumbar back muscle activity in relation to trunk movements during locomotion in man. , 1982, Acta physiologica Scandinavica.

[41]  O C J LIPPOLD,et al.  The relation between integrated action potentials in a human muscle and its isometric tension , 1952, The Journal of physiology.

[42]  A. Hill The heat of shortening and the dynamic constants of muscle , 1938 .

[43]  J Perry,et al.  EMG-force relationships in skeletal muscle. , 1981, Critical reviews in biomedical engineering.

[44]  W. Weijs,et al.  Sarcomere length and EMG activity in some jaw muscles of the rabbit. , 1982, Acta anatomica.

[45]  H. Hatze,et al.  Neuromusculoskeletal control systems modeling--A critical survey of recent developments , 1980 .

[46]  J G Webster,et al.  60-HZ interference in electrocardiography. , 1973, IEEE transactions on bio-medical engineering.

[47]  T.W. Calvert,et al.  The relationship between the surface EMG and force transients in muscle: Simulation and experimental studies , 1977, Proceedings of the IEEE.

[48]  H. Freund Motor unit and muscle activity in voluntary motor control. , 1983, Physiological reviews.