Fatal Cardiac Tamponade Associated With Posterior Spinal Instrumentation: A Case Report

Study Design. Case report of a fatal complication of pedicle screw instrumentation and review of the literature. Objective. To describe the clinical and postmortem findings in a 35‐year‐old man who sustained a T11 burst fracture that was managed by transpedicular posterior instrumentation and who died 12 days after surgery of cardiac tamponade caused by a prick injury of the right coronary artery. Summary of Background Data. Posterior pedicle screw instrumentation is considered a safe and effective method for stabilizing a spinal motion segment. Nevertheless, there are several rare but significant complications that may occur. This is the first report of a heart tamponade after transpedicular screw insertion. Methods. A 35‐year‐old man was treated for a T11 burst fracture with posterior transpedicular stabilization. The surgery was uncomplicated. Results. Twelve days after the intervention, the patient died of cardiogenic shock. Postmortem examination showed a heart tamponade of 350 mL blood originating in a prick injury of the right coronary artery. Histologic findings showed evidence that the injury was caused during surgery by a Kirschner wire. Conclusion. There are numerous possible intraoperative complications in posterior pedicle screw fixation, such as nerve root and spinal cord injuries. This case of a fatal heart tamponade after transpedicular screw insertion is rare. It shows that the surgeon must be aware of potential risks associated with such a procedure and have a comprehensive three‐dimensional understanding of the anatomic structures involved.

[1]  H. Matsuzaki,et al.  Problems and Solutions of Pedicle Screw Plate Fixation of Lumbar Spine , 1990, Spine.

[2]  O. Böstman,et al.  Complications Of Transpedicular Lumbosacral Fixation For Non-traumatic Disorders , 1997 .

[3]  S. Esses,et al.  Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. , 1993, Spine.

[4]  D. Gerlach,et al.  [2 cases of pericardial tamponade caused by migration of fracture wires from the sternoclavicular joint]. , 1984, Zeitschrift fur Rechtsmedizin. Journal of legal medicine.

[5]  M. Yahiro Comprehensive literature review. Pedicle screw fixation devices. , 1994, Spine.

[6]  D. Bradford,et al.  Complications of the Variable Screw Plate Pedicle Screw Fixation , 1991, Spine.

[7]  Matthew J. Crawford,et al.  Indications for Pedicle Fixation: Results of NASS/SRS Faculty Questionnaire , 1994, Spine.

[8]  C. Dickman,et al.  A Historical Cohort Study of Pedicle Screw Fixation in Thoracic, Lumbar, and Sacral Spinal Fusions. , 1994, Spine.

[9]  M M Panjabi,et al.  Internal Architecture of the Thoracic Pedicle: An Anatomic Study , 1996, Spine.

[10]  T N Bernard,et al.  Pedicle Diameter Determined by Computed Tomography: Its Relevance to Pedicle Screw Fixation in the Lumbar Spine , 1992, Spine.

[11]  P. Pech,et al.  CT analysis of pedicles and screw tracts after implant removal in thoracolumbar fractures. , 1993, Journal of spinal disorders.

[12]  D. Clements,et al.  Semirigid Instrumentation in the Management of Lumbar Spinal Conditions Combined With Circumferential Fusion: A Multicenter Study , 1996, Spine.

[13]  I. Redlund‐Johnell,et al.  Complications After Transpedicular Stabilization of the Spine: A Survivorship Analysis of 163 Cases , 1994, Spine.

[14]  S. Ogbuihi,et al.  Über zwei Fälle von Herzbeuteltamponade infolge Migration von Spickdrähten aus dem Sternoclaviculargelenk , 2004, Zeitschrift für Rechtsmedizin.

[15]  J. Weinstein,et al.  Spinal Pedicle Fixation: Reliability and Validity of Roentgenogram-Based Assessment and Surgical Factors on Successful Screw Placement , 1988, Spine.

[16]  A. Vaccaro,et al.  Potential Large Vessel Injury During Thoracolumbar Pedicle Screw Removal: A Case Report , 1997, Spine.

[17]  H. An,et al.  Placement of pedicle screws in the thoracic spine. Part I: Morphometric analysis of the thoracic vertebrae. , 1995, The Journal of bone and joint surgery. American volume.

[18]  F. Langlotz,et al.  Accuracy of Computer‐Assisted Pedicle Screw Placement: An In Vivo Computed Tomography Analysis , 1997, Spine.