Controller Design for a Stance-control Knee-ankle-foot Orthosis based on Optimization Techniques

Design of active orthosis is a challenging problem from both the dynamic simulation and control points of view. The redundancy problem of the simultaneous human-orthosis actuation is an interesting exercise to solve concerning the analytical and computational cost effectiveness. The physiological static optimization approach tries to solve the actuation sharing problem. Its objective is to quantify the contributions of muscles and active orthosis to the net joint torques in order to select the proper actuator for the joint. Depending on the disability of each patient, different controllers can be designed. As a matter of fact, the duration of the gait cycle for each patient should be different. In this paper, a PI controller is designed whose parameters are tuned by optimizing a cost function which takes into account the patients muscle power and the error of the knee angle with the reference value. Moreover, the final time is obtained by minimizing the mean of integral squared errors. The performance of the method is shown by designing the controller for three types of patients, ordered from low to high disability. The objective of this work is to use optimal control techniques based on physiological static optimization approach to the design of active orthosis and its control.

[1]  Werner Schiehlen,et al.  Dynamic Analysis of Human Gait Disorder and Metabolical Cost Estimation , 2006 .

[2]  C. K. Thomas,et al.  Muscle atrophy after human spinal cord injury , 2005 .

[3]  M K Lebiedowska,et al.  Passive dynamics of the knee joint in healthy children and children affected by spastic paresis. , 1999, Clinical biomechanics.

[4]  Aaron M. Dollar,et al.  Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art , 2008, IEEE Transactions on Robotics.

[5]  F. Romero,et al.  A simple approach to estimate muscle forces and orthosis actuation in powered assisted walking of spinal cord-injured subjects , 2011 .

[6]  Giulio Rosati,et al.  Low-cost Enzyme-based Biosensor for Lactic Acid Amperometric Detection - Electrical Modeling and Validation for Clinical and Food Processing Applications , 2012, BIODEVICES.

[7]  Daniel P Ferris,et al.  Invariant ankle moment patterns when walking with and without a robotic ankle exoskeleton. , 2010, Journal of biomechanics.

[8]  Paulo Mateus Mendes,et al.  Towards Wearable and Continuous 12-lead Electrocardiogram Monitoring - Synthesis of the 12-lead Electrocardiogram using 3 Wireless Single-lead Sensors , 2012, BIODEVICES.

[9]  Urbano Lugrís,et al.  Simulation and design of an active orthosis for an incomplete spinal cord injured subject , 2011 .

[10]  D W Moran,et al.  A computationally efficient method for solving the redundant problem in biomechanics. , 1995, Journal of biomechanics.

[11]  F. Zajac Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control. , 1989, Critical reviews in biomedical engineering.

[12]  D. Winter Biomechanics and motor control of human gait: normal, elderly and pathological - 2nd edition , 1991 .

[13]  Jorge Martins,et al.  Evaluation of the contact forces developed in the lower limb/orthosis interface for comfort design , 2010 .

[14]  Marko Ackermann,et al.  Dynamics and Energetics of Walking with Prostheses , 2007 .

[15]  Robert Riener,et al.  Analysis of passive elastic joint moment in paraplegics , 2000, IEEE Transactions on Biomedical Engineering.

[16]  R. Triolo,et al.  Effects of spinal cord injury on lower-limb passive joint moments revealed through a nonlinear viscoelastic model. , 2004, Journal of rehabilitation research and development.

[17]  R. Brand,et al.  The biomechanics and motor control of human gait: Normal, elderly, and pathological , 1992 .

[18]  Josep M. Font-Llagunes,et al.  HYBRID MODELING AND FRACTIONAL CONTROL OF A SCKAFO ORTHOSIS FOR GAIT ASSISTANCE , 2011 .