Impacts of selected stimulation patterns on the perception threshold in electrocutaneous stimulation

BackgroundConsistency is one of the most important concerns to convey stable artificially induced sensory feedback. However, the constancy of perceived sensations cannot be guaranteed, as the artificially evoked sensation is a function of the interaction of stimulation parameters. The hypothesis of this study is that the selected stimulation parameters in multi-electrode cutaneous stimulation have significant impacts on the perception threshold.MethodsThe investigated parameters included the stimulated location, the number of active electrodes, the number of pulses, and the interleaved time between a pair of electrodes. Biphasic, rectangular pulses were applied via five surface electrodes placed on the forearm of 12 healthy subjects.ResultsOur main findings were: 1) the perception thresholds at the five stimulated locations were significantly different (p < 0.0001), 2) dual-channel simultaneous stimulation lowered the perception thresholds and led to smaller variance in perception thresholds compared to single-channel stimulation, 3) the perception threshold was inversely related to the number of pulses, and 4) the perception threshold increased with increasing interleaved time when the interleaved time between two electrodes was below 500 μs.ConclusionsTo maintain a consistent perception threshold, our findings indicate that dual-channel simultaneous stimulation with at least five pulses should be used, and that the interleaved time between two electrodes should be longer than 500 μs. We believe that these findings have implications for design of reliable sensory feedback codes.

[1]  R E Prior,et al.  Supplemental sensory feedback for the VA/NU myoelectric hand. Background and preliminary designs. , 1976, Bulletin of prosthetics research.

[2]  H. Schmidl The importance of information feedback in prostheses for the upper limbs. , 1977, Prosthetics and orthotics international.

[3]  A. Szeto,et al.  Electrocutaneous Pulse Rate and Pulse Width Psychometric Functions for Sensory Communications , 1979, Human factors.

[4]  Frank A. Saunders,et al.  Electrocutaneous Stimulation for Sensory Communication in Rehabilitation Engineering , 1982, IEEE Transactions on Biomedical Engineering.

[5]  B. Querleux,et al.  Assessment of aging of the human skin by in vivo ultrasonic imaging. , 1989, The Journal of investigative dermatology.

[6]  W.J. Tompkins,et al.  Electrotactile and vibrotactile displays for sensory substitution systems , 1991, IEEE Transactions on Biomedical Engineering.

[7]  Karen Milchus,et al.  Sensory Feedback for Enhancing Upper Extremity Neuromuscular Prostheses , 1991 .

[8]  W.L.C. Rutten,et al.  Sensitivity and selectivity of intraneural stimulation using a silicon electrode array , 1991, IEEE Transactions on Biomedical Engineering.

[9]  Ayse G. Canseven,et al.  Electrical Properties of The Skin , 1992 .

[10]  P E Patterson,et al.  Design and evaluation of a sensory feedback system that provides grasping pressure in a myoelectric hand. , 1992, Journal of rehabilitation research and development.

[11]  G. Alon,et al.  The effects of selected stimulus waveforms on pulse and phase characteristics at sensory and motor thresholds. , 1994, Physical therapy.

[12]  A B Vallbo,et al.  Receptive field characteristics of tactile units with myelinated afferents in hairy skin of human subjects. , 1995, The Journal of physiology.

[13]  D. Atkins,et al.  Epidemiologic Overview of Individuals with Upper-Limb Loss and Their Reported Research Priorities , 1996 .

[14]  G. Gescheider Psychophysics: The Fundamentals , 1997 .

[15]  W. Ehrenstein,et al.  Psychophysical Methods , 1999 .

[16]  Håkan Johansson,et al.  Modern Techniques in Neuroscience Research , 1999, Springer Berlin Heidelberg.

[17]  H. Flor,et al.  Effect of sensory discrimination training on cortical reorganisation and phantom limb pain , 2001, The Lancet.

[18]  Herta Flor,et al.  Phantom-limb pain: characteristics, causes, and treatment , 2002, The Lancet Neurology.

[19]  R. Gracely,et al.  Stability and reliability of detection thresholds for human A-Beta and A-delta sensory afferents determined by cutaneous electrical stimulation. , 2003, Journal of pain and symptom management.

[20]  Johan Wessberg,et al.  Receptive field properties of unmyelinated tactile afferents in the human skin. , 2003, Journal of neurophysiology.

[21]  G.S. Dhillon,et al.  Direct neural sensory feedback and control of a prosthetic arm , 2005, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[22]  R. Okuno,et al.  Tactile Substitution System for Transmitting a Few Words to a Prosthetic Hand User , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[23]  Ken Yoshida,et al.  Current density imaging and electrically induced skin burns under surface electrodes , 2005, IEEE Transactions on Biomedical Engineering.

[24]  E. Pfeiffer Electrical stimulation of sensory nerves with skin electrodes for research, diagnosis, communication and behavioral conditioning: A survey , 1968, Medical and biological engineering.

[25]  T. Yamamoto,et al.  Non-linear electrical properties of skin in the low frequency range , 1981, Medical and Biological Engineering and Computing.

[26]  T. Beeker,et al.  Artificial touch in a hand-prosthesis , 2006, Medical and biological engineering.

[27]  R. N. Scott,et al.  Sensory-feedback system compatible with myoelectric control , 2006, Medical and Biological Engineering and Computing.

[28]  G. Shannon A myoelectrically-controlled prosthesis with sensory feedback , 2006, Medical and Biological Engineering and Computing.

[29]  Andrew Y. J. Szeto,et al.  Electrocutaneous code pairs for artificial sensory communication systems , 2006, Annals of Biomedical Engineering.

[30]  Katja Wiech,et al.  Tactile discrimination, but not tactile stimulation alone, reduces chronic limb pain , 2008, PAIN®.

[31]  M. Jubeau,et al.  Differences in electrical stimulation thresholds between men and women , 2008, Annals of neurology.

[32]  Andreas Kuhn,et al.  Modeling transcutaneous electrical stimulation , 2008 .

[33]  G. Lundborg,et al.  SmartHand tactile display: A new concept for providing sensory feedback in hand prostheses , 2010, Scandinavian journal of plastic and reconstructive surgery and hand surgery.