Performance evaluation of an integrated automotive air conditioning and heat pump system

This study deals with the performance characteristics of an R134a automotive air conditioning system capable of operating as an air-to-air heat pump using ambient air as a heat source. For this aim, an experimental analysis has been performed on a plant made up of original components from an automobile air conditioning system and some extra equipment employed to operate the system in the reverse direction. The system has been tested in the air conditioning and heat pump modes by varying the compressor speed and air temperatures at the inlets of the indoor and outdoor coils. Evaluation of the data gathered in steady state test runs has shown the effects of the operating conditions on the capacity, coefficient of performance, compressor discharge temperature and the rate of exergy destroyed by each component of the system for both operation modes. It has been observed that the heat pump operation provides adequate heating only in mild weather conditions, and the heating capacity drops sharply with decreasing outdoor temperature. However, compared with the air conditioning operation, the heat pump operation usually yields a higher coefficient of performance and a lower rate of exergy destruction per unit capacity. It is also possible to improve the heating mode performance of the system by redesigning the indoor coil, using another refrigerant with a higher heat rejection rate in the condenser and employing a better heat source such as the engine coolant or exhaust gases.

[1]  Khalid A. Joudi,et al.  Experimental and computer performance study of an automotive air conditioning system with alternative refrigerants , 2003 .

[2]  Hans W. Wienholt,et al.  Visco® Heater for Low Consumption Vehicles , 2003 .

[3]  Omar M. Al-Rabghi,et al.  Retrofitting R-12 car air conditioner with R-134a refrigerant , 2000 .

[4]  M. S. Bhatti Riding in comfort : Part I , 1999 .

[5]  M. S. Bhatti Enhancement of R-134a automotive air-conditioning system , 1999 .

[6]  Mahmoud Ghodbane,et al.  An Investigation of R152a and Hydrocarbon Refrigerants in Mobile Air Conditioning , 1999 .

[7]  J. Jabardo,et al.  Modeling and experimental evaluation of an automotive air conditioning system with a variable capacity compressor , 2002 .

[8]  Dongsoo Jung,et al.  Evaluation of supplementary/retrofit refrigerants for automobile air-conditioners charged with CFC12 , 1999 .

[9]  J. Yoo,et al.  Performance analysis and simulation of automobile air conditioning system , 2000 .

[10]  Prasad Shripad Kadle,et al.  On-Vehicle Performance Comparison of an R-152a and R-134a Heat Pump System , 2003 .

[11]  O. Kaynakli,et al.  An experimental analysis of automotive air conditioning system , 2003 .

[12]  John J. Meyer,et al.  R134a Heat Pump for Improved Passenger Comfort , 2004 .

[13]  Piotr A. Domanski,et al.  Comparitive analysis of an automotive air conditioning systems operating with CO2 and R134a , 2002 .

[14]  Eric B. Ratts,et al.  An experimental analysis of the effect of refrigerant charge level on an automotive refrigeration system , 2000 .