The polarization Sagnac interferometer for gravitational wave detection

Future advanced interferometric gravitational wave detectors will be limited by thermal distortions induced by high circulating power. An all-reflective configuration based on the Sagnac interferometer, presented here, is well suited to operation with high circulating power. A polarization scheme is presented that allows the interferometer to be used in a reciprocal configuration, so that static imperfections and thermally induced distortions of the beamsplitter and optics have a minimal effect on the interference contrast. The necessary low-frequency response of the interferometer requires delay-lines in the arms. To deal with the noise introduced by scattered light in the delay lines, a laser frequency sweep is presented that frequency shifts the scattered light so that it does not produce noise in the measurement band. The control requirements and alignment tolerances are calculated for the components of the detector and they are compared with the levels necessary for an alternative interferometer configuration, the Fabry-Perot Michelson, to highlight the advantages and disadvantages of the polarization Sagnac interferometer. The all-reflective delay-line polarization Sagnac interferometer design is demonstrated on-a 10 m prototype interferometer with suspended optics that incorpe rates the Bser frequency sweep to provide a shot-noise-limited phase sensitivity of A+ = l ~ ~ r a d ~ z ~ / ~ at frequencies as low as 200 Hz. Scaling this prototype to several kilometers with kilowatts of circulating power requires several technical improvements in high-power solid-state lasers, second harmonic generation, and the fabrication of large mirrors, which are likely to be made in the next 10 years.

[1]  M. Fejer,et al.  Estimation of thermal noise in the mirrors of laser interferometric gravitational wave detectors: Two point correlation function , 1997 .

[2]  M. Regehr Signal Extraction and Control for an Interferometric Gravitational Wave Detector. , 1995 .

[3]  M. Fejer,et al.  Balanced heterodyne signal extraction in a postmodulated Sagnac interferometer at low frequency. , 1997, Optics letters.

[4]  Carlton M. Caves,et al.  Quantum-Mechanical Radiation-Pressure Fluctuations in an Interferometer , 1980 .

[5]  M. Fejer,et al.  Polarization Sagnac interferometer with a reflective grating beam splitter. , 2000, Optics letters.

[6]  C. Caves Quantum Mechanical Noise in an Interferometer , 1981 .

[7]  D. McClelland,et al.  Experimental demonstration of resonant sideband extraction in a sagnac interferometer. , 1998, Applied optics.

[8]  R. J. Sandeman,et al.  AIGO: A southern hemisphere second generation gravitational wave observatory , 1994 .

[9]  J B McManus,et al.  Astigmatic mirror multipass absorption cells for long-path-length spectroscopy. , 1995, Applied optics.

[10]  J. Armstrong,et al.  Theory of Interferometric Analysis of Laser Phase Noise , 1966 .

[11]  M. Fejer,et al.  Quasi-phase-matched second harmonic generation: tuning and tolerances , 1992 .

[12]  Gustafson,et al.  Sagnac interferometer for gravitational-wave detection. , 1996, Physical review letters.

[13]  D. McClelland,et al.  Analysis of light noise sources in a recycled Michelson interferometer with Fabry-Perot arms. , 2000, Journal of the Optical Society of America. A, Optics, image science, and vision.

[14]  Herwig Kogelnik,et al.  Off-Axis Paths in Spherical Mirror Interferometers , 1964 .

[15]  Bernard F. Schutz,et al.  A First Course in General Relativity , 2022 .

[16]  M. Fejer,et al.  Polarization Sagnac interferometer with a common-path local oscillator for heterodyne detection , 1999 .

[17]  R. Chiao,et al.  Gravitational radiation antennas using the Sagnac effect , 1982 .

[18]  M. Regehr,et al.  Demonstration of a power-recycled Michelson interferometer with Fabry-Perot arms by frontal modulation. , 1995, Optics letters.