Study on Magnetic Probe Calibration in Near-field Measurement System for EMI Application

Near-field measurement, as an efficient method for studying the electromagnetic interference (EMI) problem, is becoming increasingly important. The calibration of the near-field probe is a critical part in the measurement procedure. This paper presents a fast and effective calibration method of magnetic probe. The factors that influence the calibration method is analyzed and discussed. Two kinds of calibration structures are designed and fabricated to determine the probe factor (PF) of two magnetic probes, which are horizontal magnetic field probe and vertical magnetic field probe, respectively. Moreover, PF is obtained through comparing the measurement data with the simulation data of the same calibration structure. Another sample is designed and fabricated to verify the obtained PF and the calibration method. The measurement results match simulation results well with the relative errors at the “large signal region” less than 20%, which indicates a good accuracy of the calibration method.

[1]  B. Mazari,et al.  Modeling Magnetic Radiations of Electronic Circuits Using Near-Field Scanning Method , 2007, IEEE Transactions on Electromagnetic Compatibility.

[2]  Liqiang Cao,et al.  A shielding structure with conductive adhesive coated on molding compound in 3D package , 2013, 2013 IEEE 15th Electronics Packaging Technology Conference (EPTC 2013).

[3]  T. Sarkar,et al.  Planar near-field to far-field transformation using an equivalent magnetic current approach , 1992 .

[4]  A. Louis,et al.  A Radiated Emission Model Compatible to a Commercial Electromagnetic Simulation Tool , 2009, 2009 20th International Zurich Symposium on Electromagnetic Compatibility.

[5]  B. Mazari,et al.  Applications of the Near-Field Techniques in EMC Investigations , 2007, IEEE Transactions on Electromagnetic Compatibility.

[6]  Jun Fan Near-field scanning for EM emission characterization , 2015, IEEE Electromagnetic Compatibility Magazine.

[7]  D. M. Kerns Correction of near-field antenna measurements made with an arbitrary but known measuring antenna , 1970 .

[8]  W. Joseph,et al.  The influence of the measurement probe on the evaluation of electromagnetic fields , 2003 .

[9]  Ji Zhang,et al.  An Effective Method of Probe Calibration in Phase-Resolved Near-Field Scanning for EMI Application , 2013, IEEE Transactions on Instrumentation and Measurement.

[10]  Fengman Liu,et al.  Study on a Conformal Shielding Structure With Conductive Adhesive Coated on Molding Compound in 3-D Packages , 2016, IEEE Transactions on Electromagnetic Compatibility.

[11]  Tapan K. Sarkar,et al.  Near-field to near/far-field transformation for arbitrary near-field geometry utilizing an equivalent electric current and MoM , 1999 .

[12]  R. King,et al.  The loop antenna as a probe , 1964 .