Head-repositioning does not reduce the reproducibility of fMRI activation in a block-design motor task

It is hypothesized that, based upon partial volume effects and spatial non-uniformities of the scanning environment, repositioning a subject's head inside the head coil between separate functional MRI scans will reduce the reproducibility of fMRI activation compared to a series of functional runs where the subject's head remains in the same position. Nine subjects underwent fMRI scanning where they performed a sequential, oppositional finger-tapping task. The first five runs were conducted with the subject's head remaining stable inside the head coil. Following this, four more runs were collected after the subject removed and replaced his/her head inside the head coil before each run. The coefficient of variation was calculated for four metrics: the distance from the anterior commisure to the center of mass of sensorimotor activation, maximum t-statistic, activation volume, and average percent signal change. These values were compared for five head-stabilization runs and five head-repositioning runs. Voxelwise intraclass correlation coefficients were also calculated to assess the spatial distribution of sources of variance. Interestingly, head repositioning was not seen to significantly affect the reproducibility of fMRI activation (p<0.05). In addition, the threshold level affected the reproducibility of activation volume and percent signal change.

[1]  G. Glover,et al.  Neuroimaging at 1.5 T and 3.0 T: Comparison of oxygenation‐sensitive magnetic resonance imaging , 2001, Magnetic resonance in medicine.

[2]  Michael B. Miller,et al.  How reliable are the results from functional magnetic resonance imaging? , 2010, Annals of the New York Academy of Sciences.

[3]  R L Ehman,et al.  Imaging of cerebral activation at 1.5 T: optimizing a technique for conventional hardware. , 1994, Radiology.

[4]  Lee Friedman,et al.  Report on a multicenter fMRI quality assurance protocol , 2006, Journal of magnetic resonance imaging : JMRI.

[5]  G. Glover,et al.  Physiological noise in oxygenation‐sensitive magnetic resonance imaging , 2001, Magnetic resonance in medicine.

[6]  Mark S. Cohen,et al.  Parametric Analysis of fMRI Data Using Linear Systems Methods , 1997, NeuroImage.

[7]  Thomas E. Nichols,et al.  Thresholding of Statistical Maps in Functional Neuroimaging Using the False Discovery Rate , 2002, NeuroImage.

[8]  Guy Marchal,et al.  Automated multi-moda lity image registration based on information theory , 1995 .

[9]  Paul J. Laurienti,et al.  Dietary Caffeine Consumption Modulates fMRI Measures , 2002, NeuroImage.

[10]  D. Altman,et al.  Measurement error. , 1996, BMJ.

[11]  Nick F. Ramsey,et al.  Test–retest reliability of fMRI activation during prosaccades and antisaccades , 2007, NeuroImage.

[12]  M Alecci,et al.  Radio frequency magnetic field mapping of a 3 Tesla birdcage coil: Experimental and theoretical dependence on sample properties , 2001, Magnetic resonance in medicine.

[13]  R W Cox,et al.  AFNI: software for analysis and visualization of functional magnetic resonance neuroimages. , 1996, Computers and biomedical research, an international journal.

[14]  J. Frahm,et al.  Functional MRI of human brain activation at high spatial resolution , 1993, Magnetic resonance in medicine.

[15]  Yul-Wan Sung,et al.  Functional magnetic resonance imaging , 2004, Scholarpedia.

[16]  Yu-Chung N. Cheng,et al.  Magnetic Resonance Imaging: Physical Principles and Sequence Design , 1999 .

[17]  Cornelius Weiller,et al.  Functional magnetic resonance imaging: A review of methodological aspects and clinical applications , 2003, Journal of magnetic resonance imaging : JMRI.

[18]  G H Glover,et al.  Image‐based method for retrospective correction of physiological motion effects in fMRI: RETROICOR , 2000, Magnetic resonance in medicine.

[19]  Guy Marchal,et al.  Automated multi-modality image registration based on information theory , 1995 .

[21]  R. C. Oldfield The assessment and analysis of handedness: the Edinburgh inventory. , 1971, Neuropsychologia.

[22]  Karl J. Friston,et al.  Variability in fMRI: An Examination of Intersession Differences , 2000, NeuroImage.

[23]  L. Shah,et al.  Functional magnetic resonance imaging. , 2010, Seminars in roentgenology.

[24]  S. Rombouts,et al.  Test-retest analysis with functional MR of the activated area in the human visual cortex. , 1997, AJNR. American journal of neuroradiology.

[25]  Stephen M. Smith,et al.  A global optimisation method for robust affine registration of brain images , 2001, Medical Image Anal..

[26]  Darren R. Fuerst Clinical applications of functional brain MRI, S. Rombouts, F. Barkhoff, P. Scheltens (Eds.). Oxford University Press, Great Clarendon Street, Oxford (2007), 386 pages, OX2 6DP, ISBN 978-0-19-856629-8, $245.00 (US) , 2009 .

[27]  B. Biswal,et al.  High‐resolution fMRI using multislice partial k‐space GR‐EPI with cubic voxels , 2001, Magnetic resonance in medicine.

[28]  Mark Hallett,et al.  The variability of serial fMRI data: Correlation between a visual and a motor task , 2000, Neuroreport.

[29]  J. Fleiss,et al.  Intraclass correlations: uses in assessing rater reliability. , 1979, Psychological bulletin.

[30]  Michael S. Beauchamp,et al.  A new method for improving functional-to-structural MRI alignment using local Pearson correlation , 2009, NeuroImage.

[31]  S. Rombouts,et al.  Within-subject reproducibility of visual activation patterns with functional magnetic resonance imaging using multislice echo planar imaging. , 1998, Magnetic resonance imaging.

[32]  Peter A. Bandettini,et al.  Detection versus Estimation in Event-Related fMRI: Choosing the Optimal Stimulus Timing , 2002, NeuroImage.

[33]  R W Cox,et al.  Real‐time 3D image registration for functional MRI , 1999, Magnetic resonance in medicine.

[34]  Nick F. Ramsey,et al.  Within-subject variation in BOLD-fMRI signal changes across repeated measurements: Quantification and implications for sample size , 2008, NeuroImage.

[35]  M S Cohen,et al.  Stability, repeatability, and the expression of signal magnitude in functional magnetic resonance imaging , 1999, Journal of magnetic resonance imaging : JMRI.