The Current Role of Image Compression Standards in Medical Imaging

With the increasing utilization of medical imaging in clinical practice and the growing dimensions of data volumes generated by various medical imaging modalities, the distribution, storage, and management of digital medical image data sets requires data compression. Over the past few decades, several image compression standards have been proposed by international standardization organizations. This paper discusses the current status of these image compression standards in medical imaging applications together with some of the legal and regulatory issues surrounding the use of compression in medical settings.

[1]  Victor Sanchez Sample-based edge prediction based on gradients for lossless screen content coding in HEVC , 2015, 2015 Picture Coding Symposium (PCS).

[2]  Bostjan Likar,et al.  The impact of image information on compressibility and degradation in medical image compression. , 2006, Medical physics.

[3]  S. Sujatha,et al.  3D Medical Image Compression: A Review , 2015 .

[4]  N. Hassani,et al.  Principles of computerized tomography. , 1976, Journal of the National Medical Association.

[5]  Yo-Sung Ho,et al.  Differential Pixel Value Coding for HEVC Lossless Compression , 2013 .

[6]  Michael W. Marcellin,et al.  JPEG2000 - image compression fundamentals, standards and practice , 2002, The Kluwer International Series in Engineering and Computer Science.

[7]  V.R.Vijayakuymar,et al.  A Survey on Various Compression Methods for Medical Images , 2012 .

[8]  Chandrashekhar Kamargaonkar,et al.  A SURVEY ON VARIOUS MEDICAL IMAGE COMPRESSION TECHNIQUES , 2013 .

[9]  Joan L. Mitchell,et al.  JPEG: Still Image Data Compression Standard , 1992 .

[10]  Chuohao Yeo,et al.  Residual DPCM for lossless coding in HEVC , 2013, 2013 IEEE International Conference on Acoustics, Speech and Signal Processing.

[11]  Kyle J. Myers,et al.  Model observers for assessment of image quality , 1993 .

[12]  Sheila S. Hemami,et al.  Visually lossless compression of digitized radiographs based on contrast sensitivity and visual masking , 2005, SPIE Medical Imaging.

[13]  David A Koff,et al.  An overview of digital compression of medical images: can we use lossy image compression in radiology? , 2006, Canadian Association of Radiologists journal = Journal l'Association canadienne des radiologistes.

[14]  Samy Ait-Aoudia,et al.  Lossless Compression of Volumetric Medical Data , 2006, ISCIS.

[15]  Zhen Liu,et al.  JPEG2000 encoding with perceptual distortion control , 2006, IEEE Transactions on Image Processing.

[16]  Miguel P. Eckstein,et al.  Automated optimization of JPEG 2000 encoder options based on model observer performance for detecting variable signals in X-ray coronary angiograms , 2004, IEEE Transactions on Medical Imaging.

[17]  Limin Luo,et al.  Extended PCJO for the Detection-Localization of Hypersignals and Hyposignals in CT Images , 2017, IEEE Access.

[18]  Wolfgang Heidrich,et al.  HDR-VDP-2: a calibrated visual metric for visibility and quality predictions in all luminance conditions , 2011, SIGGRAPH 2011.

[19]  Bradley James Erickson,et al.  Irreversible Compression of Medical Images , 2002, Journal of Digital Imaging.

[20]  Guillermo Sapiro,et al.  LOCO-I: a low complexity, context-based, lossless image compression algorithm , 1996, Proceedings of Data Compression Conference - DCC '96.

[21]  J. A. M. Nijhof,et al.  Compressed Medical Images And Enhanced Fault Detection Within An ARC-NEMA Compatidle Picture Archiving And Communications System , 1987, Medical Imaging.

[22]  R. F. Wagner,et al.  Statistics of Speckle in Ultrasound B-Scans , 1983, IEEE Transactions on Sonics and Ultrasonics.

[23]  Charilaos A. Christopoulos,et al.  Region of interest coding in JPEG 2000 , 2002, Signal Process. Image Commun..

[24]  Michael W. Marcellin,et al.  Compression of multislice CT: 2D vs. 3D JPEG2000 and effects of slice thickness , 2005, SPIE Medical Imaging.

[25]  Nam Ling,et al.  Lossy and lossless intra coding performance evaluation: HEVC, H.264/AVC, JPEG 2000 and JPEG LS , 2012, Proceedings of The 2012 Asia Pacific Signal and Information Processing Association Annual Summit and Conference.

[26]  Thomas Richter,et al.  JPEG2000 2D and 3D reversible compressions of thin-section chest CT images: improving compressibility by increasing data redundancy outside the body region. , 2011, Radiology.

[27]  Michael W. Marcellin,et al.  Image compression based on task-specific information , 2014, 2014 IEEE International Conference on Image Processing (ICIP).

[28]  Ajay Luthra,et al.  The H.264/AVC Advanced Video Coding standard: overview and introduction to the fidelity range extensions , 2004, SPIE Optics + Photonics.

[29]  H.H. Barrett,et al.  Model observers for assessment of image quality , 1993, 2002 IEEE Nuclear Science Symposium Conference Record.

[30]  Mrs. S. Sridevi,et al.  A Survey on Various Compression Methods for Medical Images , 2016 .

[31]  Nuno M. M. Rodrigues,et al.  Lossless Compression of Medical Images Using 3-D Predictors , 2017, IEEE Transactions on Medical Imaging.

[32]  Joan Bartrina-Rapesta,et al.  Lossless compression of medical images based on HEVC intra coding , 2014, 2014 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP).

[33]  Susan S. Young,et al.  JPEG 2000 compression of medical imagery , 2000, Medical Imaging.

[34]  Francesc Aulí Llinàs,et al.  Improvements to HEVC Intra Coding for Lossless Medical Image Compression , 2014, 2014 Data Compression Conference.

[35]  Solomon W. Golomb,et al.  Run-length encodings (Corresp.) , 1966, IEEE Trans. Inf. Theory.

[36]  Eero P. Simoncelli,et al.  Image quality assessment: from error visibility to structural similarity , 2004, IEEE Transactions on Image Processing.

[37]  S. Cherry,et al.  Physics in Nuclear Medicine , 2004 .

[38]  Elsa D. Angelini,et al.  Specificities of Physiological Signals and Medical Images , 2010 .

[39]  Francesc Aulí Llinàs,et al.  HEVC-based lossless compression of Whole Slide pathology images , 2014, 2014 IEEE Global Conference on Signal and Information Processing (GlobalSIP).

[40]  Nico Karssemeijer,et al.  Lossless Compression of Digital Mammograms , 2006, Digital Mammography / IWDM.

[41]  Mike May,et al.  A better lens on disease. , 2010, Scientific American.

[42]  Amine Nait-Ali,et al.  Compression of Biomedical Images and Signals , 2008 .

[43]  F. Rawson Medical Imaging : Is the Growth Boom Over ? , 2022 .

[44]  Joan Bartrina-Rapesta,et al.  Rate control for lossless region of interest coding in HEVC intra-coding with applications to digital pathology images , 2015, 2015 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP).

[45]  Jeffrey C. Bamber,et al.  Physical principles of medical ultrasonics , 2004 .

[46]  H. Gudbjartsson,et al.  The rician distribution of noisy mri data , 1995, Magnetic resonance in medicine.

[47]  D. Hughes,et al.  Trends in the utilization of medical imaging from 2003 to 2011: clinical encounters offer a complementary patient-centered focus. , 2013, Journal of the American College of Radiology : JACR.

[48]  Wen Gao,et al.  HEVC Lossless Coding and Improvements , 2012, IEEE Transactions on Circuits and Systems for Video Technology.

[49]  Gloria Menegaz,et al.  Trends in Medical Image Compression , 2006 .

[50]  Michael W. Marcellin,et al.  Visually Lossless Encoding for JPEG2000 , 2013, IEEE Transactions on Image Processing.

[51]  Wen Gao,et al.  On lossless coding for HEVC , 2013, Electronic Imaging.

[52]  Mark A Helvie,et al.  Digital mammography imaging: breast tomosynthesis and advanced applications. , 2010, Radiologic clinics of North America.

[53]  Yeong-Gil Shin,et al.  Advantage in image fidelity and additional computing time of JPEG2000 3D in comparison to JPEG2000 in compressing abdomen CT image datasets of different section thicknesses. , 2010, Medical physics.

[54]  Peter Schelkens,et al.  HEVC-based video coding with lossless region of interest for telemedicine applications , 2013, 2013 20th International Conference on Systems, Signals and Image Processing (IWSSIP).

[55]  Hari Kalva,et al.  High Bit-Depth Medical Image Compression With HEVC , 2018, IEEE Journal of Biomedical and Health Informatics.

[56]  H. K. Huang,et al.  Radiologic image compression-a review , 1995, Proc. IEEE.

[57]  Miguel Hernandez-Cabronero Feng Liu Image Data Used in the Simulations of The Role of Image Compression Standards in Medical Imaging: Current Status and Future Trends , 2016 .

[58]  V. Sridhar,et al.  A Review of the Effective Techniques of Compression in Medical Image Processing , 2014 .

[59]  Bruce I. Reiner,et al.  Discrete cosine transform JPEG compression vs. 2D JPEG2000 compression: JNDmetrix visual discrimination model image quality analysis , 2005, SPIE Medical Imaging.

[60]  S. Bhavani A Survey On Coding Algorithms In Medical Image Compression , 2010 .

[61]  Ukrit M.Ferni,et al.  A Survey on Lossless Compression for Medical Images , 2011 .

[62]  Patrick Le Callet,et al.  A Perceptually Relevant Channelized Joint Observer (PCJO) for the Detection-Localization of Parametric Signals , 2012, IEEE Transactions on Medical Imaging.

[63]  Detlev Marpe,et al.  Overview of the Range Extensions for the HEVC Standard: Tools, Profiles, and Performance , 2016, IEEE Transactions on Circuits and Systems for Video Technology.

[64]  S. Golomb Run-length encodings. , 1966 .

[65]  Gary J. Sullivan,et al.  HD Photo: a new image coding technology for digital photography , 2007, SPIE Optical Engineering + Applications.

[66]  Weili Lin Principles of magnetic resonance imaging: a signal processing perspective [Book Review] , 2000, IEEE Engineering in Medicine and Biology Magazine.

[67]  Miguel P Eckstein,et al.  Task-based model/human observer evaluation of SPIHT wavelet compression with human visual system-based quantization. , 2005, Academic radiology.

[68]  Roman Starosolski Performance evaluation of lossless medical and natural continuous tone image compression algorithms , 2005, SPIE Optics + Optoelectronics.

[69]  Pablo G. Tahoces,et al.  Effects of JPEG2000 data compression on an automated system for detecting clustered microcalcifications in digital mammograms , 2006, IEEE Transactions on Information Technology in Biomedicine.

[70]  David A. Clunie,et al.  Lossless compression of grayscale medical images: effectiveness of traditional and state-of-the-art approaches , 2000, Medical Imaging.

[71]  Gary J. Sullivan,et al.  Comparison of the Coding Efficiency of Video Coding Standards—Including High Efficiency Video Coding (HEVC) , 2012, IEEE Transactions on Circuits and Systems for Video Technology.

[72]  April Khademi,et al.  Pan-Canadian Evaluation of Irreversible Compression Ratios (“Lossy” Compression) for Development of National Guidelines , 2008, Journal of Digital Imaging.

[73]  Peter Mildenberger,et al.  Kompression digitaler Bilddaten in der Radiologie – Ergebnisse einer Konsensuskonferenz , 2009 .

[74]  D. Robinson,et al.  Properties of Noise in Positron Emission Tomography Images Reconstructed with Filtered-Backprojection and Row-Action Maximum Likelihood Algorithm , 2013, Journal of Digital Imaging.

[75]  Guillermo Sapiro,et al.  The LOCO-I lossless image compression algorithm: principles and standardization into JPEG-LS , 2000, IEEE Trans. Image Process..