A new active position sensing method for ropeless elevator

Traditional cable driven elevators perform poorly in high-rise buildings because the weight of the cable limits the payload, and its elasticity degrades control performance. Further, it is not mechanically possible to include several elevator cars in the same hoistway because of the cable. However such multi-car elevator systems are desirable since they reduce passenger waiting time and reduce the space requirements of the elevator system. A promising solution is to use long armature linear motors spanning the hoistway to directly drive elevator cages. In such applications, the mover position sensing method must be explicitly addressed since most active position sensing methods require traveling cables, which are also an obstacle for multi-car elevator systems. In this paper, the linear-motor active position sensing method is formally introduced and the principle of operation, design and real-time operation methods are presented. The proposed method is used to measure the position of the mover of a long armature permanent magnet linear synchronous motor requiring no active components on the mover, thus traveling cables are eliminated. The principle of operation is inspired by linear variable differential transformer: A magnetic shunt positioned at a fixed distance ahead of the mover deforms the magnetic field created by one of the armature coils. The deformation can be determined by measuring the induced voltages on the neighboring coils, and the position of the shunt, and thus the mover, can be calculated. A design method for the optimal dimensions of the shunt for a given armature to provide long measurement range and small maximum position error is presented, accompanied by a real-time measurement algorithm that will enable the motor to be driven using the method. Finally the method is verified by simulations and experimental results conducted on a full scale linear-motor elevator prototype that was constructed in the laboratory.

[1]  Alessandro Masi,et al.  Automatic Test Bench for Measurement of Magnetic Interference on LVDTs , 2011, IEEE Transactions on Instrumentation and Measurement.

[2]  Masafumi Miyatake,et al.  A Proposal of a Ropeless Lift System and Evaluation of its Feasibility , 1999 .

[3]  A Onat,et al.  Design and Implementation of a Linear Motor for Multicar Elevators , 2010, IEEE/ASME Transactions on Mechatronics.

[4]  T. Lipo,et al.  Vector Control and Dynamics of AC Drives , 1996 .

[5]  S. Markon,et al.  Linear motor coils as brake actuators for Multi-car elevators , 2007, 2007 International Conference on Electrical Machines and Systems (ICEMS).

[6]  Ivor. Dulk,et al.  Modelling of a linear proportional electromagnetic actuator and possibilities of sensorless plunger position estimation , 2011, 2011 12th International Carpathian Control Conference (ICCC).

[7]  Yoshiko Wakabayashi,et al.  Algorithms for two-dimensional cutting stock and strip packing problems using dynamic programming and column generation , 2008, Eur. J. Oper. Res..

[8]  Toshiya Yoshida,et al.  Position detection for shaft-type linear motor by measurement of shaft surface magnetic flux , 2009, 2009 International Conference on Electrical Machines and Systems.

[9]  Yaonan Wang,et al.  Position-Sensorless Hybrid Sliding-Mode Control of Electric Vehicles With Brushless DC Motor , 2011, IEEE Transactions on Vehicular Technology.

[10]  Yu-wu Zhu,et al.  Structure selection of permanent magnet linear synchronous motor for ropeless elevator system , 2010, Digests of the 2010 14th Biennial IEEE Conference on Electromagnetic Field Computation.

[11]  T. Ishii Elevators for skyscrapers , 1994, IEEE Spectrum.

[12]  D. Meeker,et al.  Finite Element Method Magnetics , 2002 .

[13]  W.D. Jones How to Build a Mile-High Skyscraper , 2007, IEEE Spectrum.

[14]  Mickaël Hilairet,et al.  Design of a Fault-Tolerant Controller Based on Observers for a PMSM Drive , 2011, IEEE Transactions on Industrial Electronics.

[15]  Cláudio Alves,et al.  Arc-flow model for the two-dimensional guillotine cutting stock problem , 2010, Comput. Oper. Res..

[16]  Somboon Sangwongwanich,et al.  Stability and Dynamic Performance Improvement of Adaptive Full-Order Observers for Sensorless PMSM Drive , 2012, IEEE Transactions on Power Electronics.

[17]  Roberto Leidhold,et al.  Magnetic guiding and capacitive sensing for a passive vehicle of a long-primary linear motor , 2010, Proceedings of 14th International Power Electronics and Motion Control Conference EPE-PEMC 2010.

[18]  G Pellegrino,et al.  Sensorless Position Control of Permanent-Magnet Motors With Pulsating Current Injection and Compensation of Motor End Effects , 2011, IEEE Transactions on Industry Applications.

[19]  Tau Meng Lim,et al.  Magnetic levitation of a one DOF system using simultaneous actuation and displacement sensing technique , 2011 .

[20]  J. Y. Lee,et al.  Parametric design of magnetic sensor for transverse flux linear motors , 2011, 8th International Conference on Power Electronics - ECCE Asia.

[21]  Ahmad Amiri,et al.  Standstill and low speed sensorless control of SMPMSM by using digital FIR filter in the HF signal injection method , 2011, 2011 19th Iranian Conference on Electrical Engineering.