Evaluation of capillary haemoglobin determination for anaemia screening in blood donation settings.

BACKGROUND An accurate assessment of hemoglobin (Hb) values before donation is unavoidable for safeguarding donors' safety and fulfilling the current specifications of Hb content in blood bags. This study was hence aimed to compare a finger-prick method for Hb measurement in capillary blood with Hb assessment in venous blood using a hematological analyser. MATERIALS AND METHODS The study populations consisted in 1,014 consecutive blood donors, who had paired measurement of Hb values with HemoCue on capillary blood and UniCel DxH800 in venous blood. RESULTS A significant overestimation was found with HemoCue compared to UniCel DxH800, but the correlation between methods was significant (comprised between 0.600 and 0.759; all p<0.01) and the bias always lower than the quality specifications. The prevalence of Hb values below the gender-specific thresholds for blood donation was also not significantly different (p=0.186). DISCUSSION It can hence be concluded that the finger-prick method evaluated is a safe and reliable means for screening blood donors.

[1]  P. Tazzari,et al.  A non-invasive strategy for haemoglobin screening of blood donors. , 2014, Blood transfusion = Trasfusione del sangue.

[2]  Blood collection from intravenous lines: is one drawing site better than others? , 2014, Laboratory medicine.

[3]  S. Leitman,et al.  Capillary versus venous haemoglobin determination in the assessment of healthy blood donors , 2013, Vox sanguinis.

[4]  M. Ziemann,et al.  Reliability of capillary hemoglobin screening under routine conditions , 2011, Transfusion.

[5]  M. Keeney,et al.  Initial performance evaluation of the UniCel® DxH 800 Coulter® cellular analysis system , 2011, International journal of laboratory hematology.

[6]  G. Liumbruno,et al.  Recommendations for the transfusion of red blood cells. , 2009, Blood transfusion = Trasfusione del sangue.

[7]  J. Corral,et al.  Evaluation of four rapid methods for hemoglobin screening of whole blood donors in mobile collection settings. , 2007, Transfusion and apheresis science : official journal of the World Apheresis Association : official journal of the European Society for Haemapheresis.

[8]  R. Sawant,et al.  Evaluation of hemoglobin of blood donors deferred by the copper sulphate method for hemoglobin estimation. , 2007, Transfusion and apheresis science : official journal of the World Apheresis Association : official journal of the European Society for Haemapheresis.

[9]  G. Lippi,et al.  Preanalytical variability: the dark side of the moon in laboratory testing , 2006, Clinical chemistry and laboratory medicine.

[10]  C Ricós,et al.  Current databases on biological variation: pros, cons and progress. , 1999, Scandinavian journal of clinical and laboratory investigation.

[11]  Napier Guide to the Preparation, Use and Quality Assurance of Blood Components. , 1998 .