Effect of truncated projections on defect detection in attenuation-compensated fanbeam cardiac SPECT.

UNLABELLED For some camera systems used in cardiac SPECT, the limited field of view of fanbeam-collimated detectors produces truncation in the projection data. This truncation may generate artifacts and distortions in the transmission CT images and in the attenuation-corrected myocardial SPECT images (that use the transmission CT images as attenuation maps), thus affecting clinical diagnosis. Concern over this problem stimulated us to evaluate the effect of truncation with human observer performance studies. METHODS A three-dimensional mathematical cardiac-torso phantom that realistically models the attenuation and 201Tl uptake distributions in different organs of the upper torso was used for the investigation. Five degrees of truncation (from 0% to 40% truncation) in the projection data were simulated by the use of five different detector sizes collimated by fanbeam collimators. The attenuation maps were obtained by reconstructing the truncated transmission data generated from these fanbeam geometries. The emission data obtained with the same fanbeam geometries were reconstructed by using the maximum likelihood-expectation maximization algorithm and were corrected for attenuation using the reconstructed attenuation maps. Two observer performance studies were performed. In Study 1, the images were reconstructed without using the body contour as support, whereas in Study 2, the exact body contour was used in reconstructing both the attenuation maps and the attenuation-corrected SPECT images. RESULTS The results of the receiver operating characteristics analysis indicate that there is very little difference between detection for the various degrees of truncation, and this difference only becomes noticeable for severe truncation of greater than 40%. CONCLUSION Using the acquisition and processing methods, we found the use of the body contour as support in reconstructing truncated transmission CT and SPECT data reduces the loss of defect detectability in attenuation-compensated myocardial SPECT images due to truncated data.

[1]  C. Metz ROC Methodology in Radiologic Imaging , 1986, Investigative radiology.

[2]  G T Gullberg,et al.  SPECT liver imaging using an iterative attenuation correction algorithm and an external flood source. , 1986, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[3]  D. Bailey,et al.  Improved SPECT using simultaneous emission and transmission tomography. , 1987, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[4]  M Schwaiger,et al.  Comparison of americium-241 and technetium-99m as transmission sources for attenuation correction of thallium-201 SPECT imaging of the heart. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[5]  F D Thomas,et al.  Imaging of the human torso using cone-beam transmission CT implemented on a rotating gamma camera. , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[6]  D R Gilland,et al.  Design and clinical utility of a fan beam collimator for SPECT imaging of the head. , 1986, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[7]  B M Tsui,et al.  Evaluation of cardiac cone-beam single photon emission computed tomography using observer performance experiments and receiver operating characteristic analysis. , 1993, Investigative radiology.

[8]  G T Gullberg,et al.  Review of convergent beam tomography in single photon emission computed tomography. , 1992, Physics in medicine and biology.

[9]  K. Lange,et al.  EM reconstruction algorithms for emission and transmission tomography. , 1984, Journal of computer assisted tomography.

[10]  Lee-Tzuu Chang,et al.  Attenuation Correction and Incomplete Projection in Single Photon Emission Computed Tomography , 1979, IEEE Transactions on Nuclear Science.

[11]  F S Prato,et al.  Transmission computed tomography imaging of the head with a SPECT system and a collimated line source. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[12]  Eric C. Frey,et al.  Comparison between ML-EM and WLS-CG algorithms for SPECT image reconstruction , 1991 .

[13]  C. Metz,et al.  Maximum likelihood estimation of receiver operating characteristic (ROC) curves from continuously-distributed data. , 1998, Statistics in medicine.

[14]  K. Lange,et al.  A Theoretical Study of Some Maximum Likelihood Algorithms for Emission and Transmission Tomography , 1987, IEEE Transactions on Medical Imaging.

[15]  G.L. Zeng,et al.  Non-uniform attenuation correction using simultaneous transmission and emission converging tomography , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.

[16]  N. Pelc,et al.  An attenuated projector-backprojector for iterative SPECT reconstruction. , 1985, Physics in medicine and biology.

[17]  E C Frey,et al.  Simultaneous acquisition of emission and transmission data for improved thallium-201 cardiac SPECT imaging using a technetium-99m transmission source. , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[18]  S H Manglos,et al.  Truncation artifact suppression in cone-beam radionuclide transmission CT using maximum likelihood techniques: evaluation with human subjects. , 1992, Physics in medicine and biology.

[19]  J R Perry,et al.  Correction of nonuniform attenuation in cardiac SPECT imaging. , 1989, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[20]  T G Turkington,et al.  An evaluation of lesion detectability with cone-beam, fanbeam and parallel-beam collimation in SPECT by continuous ROC study. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[21]  R. Jaszczak,et al.  Single Photon Emission Computed Tomography Using Multi-Slice Fan Beam Collimators , 1979 .

[22]  Eric C. Frey,et al.  Reconstruction of truncated TCT and SPECT data from a right-angle dual-camera system for myocardial SPECT , 1996, 1996 IEEE Nuclear Science Symposium. Conference Record.

[23]  D R Gilland,et al.  Fast transmission CT for determining attenuation maps using a collimated line source, rotatable air-copper-lead attenuators and fan-beam collimation. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[24]  B F Hutton,et al.  A scanning line source for simultaneous emission and transmission measurements in SPECT. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[25]  H. Atkins,et al.  Thallium-201 for medical use. II: Biologic behavior. , 1975, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[26]  C E Metz,et al.  Some practical issues of experimental design and data analysis in radiological ROC studies. , 1989, Investigative radiology.