Continuous charge restoration in semiconductor detectors by means of the gate-to-drain current of the integrated front-end JFET

A continuous reset method for discharging the leakage current and the signal charge in semiconductor radiation detectors with on-chip electronics has been studied and experimentally verified. The charge collected at the output electrode of the detector is discharged by means of the gate-to-drain current of the front-end JFET integrated in the detector itself. The suitable value of gate current is reached by means of a "weak" avalanche breakdown mechanism which occurs in a high-field region of the transistor channel. When the JFET is operated in a source follower configuration, this mechanism is self-adapting to new values of leakage or signal currents.

[1]  Pavel Rehak,et al.  Semiconductor drift chamber: an application of a novel charge transport scheme , 1984 .

[2]  Heike Soltau,et al.  Silicon drift detectors for high resolution room temperature X-ray spectroscopy , 1996 .

[3]  U. Prechtel,et al.  The MPI/AIT X-ray imager (MAXI) — High speed pn CCDs for X-ray detection , 1989 .

[4]  P. Holl,et al.  Charge-sensitive amplifier front-end with an nJFET and a forward-biased reset diode , 1996 .

[5]  Norbert Meidinger,et al.  The pn-CCD on-chip electronics , 1993 .

[6]  Marco Sampietro,et al.  Source follower or charge amplifier? An experimental comparison using a detector with integrated electronics , 1996 .

[7]  M. Sampietro,et al.  Novel p-JFET embedded in silicon radiation detectors that avoids preamplifier feedback resistor , 1995, IEEE Electron Device Letters.

[8]  Richard H. Pehl,et al.  Recent Results on the Optoelectronic Feedback Preamplifier , 1970 .

[9]  K. Kano Semiconductor Devices , 1997 .

[10]  Carlo Fiorini,et al.  A new detection system for x-ray microanalysis based on a silicon drift detector with Peltier cooling , 1997 .

[11]  F. Olschner,et al.  Low noise charge sensitive preamplifier using drain current feedback , 1992, IEEE Conference on Nuclear Science Symposium and Medical Imaging.

[12]  Carlo Fiorini,et al.  Gamma ray spectroscopy with CsI(Tl) scintillator coupled to silicon drift chamber , 1997 .

[13]  S. Kavadias,et al.  A high resolution, 6 channels, silicon drift detector array with integrated JFET's designed for XAFS spectroscopy: first X-ray fluorescence excitation spectra recorded at the ESRF , 1996 .

[14]  E. Elad,et al.  Drain Feedback - A Novel Feedback Technique for Low-Noise Cryogenic Preamplifiers , 1972 .

[15]  Carlo Fiorini,et al.  Silicon drift detector with integrated p-JFET for continuous discharge of collected electrons through the gate junction , 1996 .

[16]  U. Prechtel,et al.  Experimental confirmation of a new semiconductor detector principle , 1990 .

[17]  Norbert Meidinger,et al.  New DEPMOS applications , 1993 .

[18]  S. M. Sze,et al.  Physics of semiconductor devices , 1969 .