A robust adaptive denoising framework for real-time artifact removal in scalp EEG measurements

OBJECTIVE Non-invasive measurement of human neural activity based on the scalp electroencephalogram (EEG) allows for the development of biomedical devices that interface with the nervous system for scientific, diagnostic, therapeutic, or restorative purposes. However, EEG recordings are often considered as prone to physiological and non-physiological artifacts of different types and frequency characteristics. Among them, ocular artifacts and signal drifts represent major sources of EEG contamination, particularly in real-time closed-loop brain-machine interface (BMI) applications, which require effective handling of these artifacts across sessions and in natural settings. APPROACH We extend the usage of a robust adaptive noise cancelling (ANC) scheme ([Formula: see text] filtering) for removal of eye blinks, eye motions, amplitude drifts and recording biases simultaneously. We also characterize the volume conduction, by estimating the signal propagation levels across all EEG scalp recording areas due to ocular artifact generators. We find that the amplitude and spatial distribution of ocular artifacts vary greatly depending on the electrode location. Therefore, fixed filtering parameters for all recording areas would naturally hinder the true overall performance of an ANC scheme for artifact removal. We treat each electrode as a separate sub-system to be filtered, and without the loss of generality, they are assumed to be uncorrelated and uncoupled. MAIN RESULTS Our results show over 95-99.9% correlation between the raw and processed signals at non-ocular artifact regions, and depending on the contamination profile, 40-70% correlation when ocular artifacts are dominant. We also compare our results with the offline independent component analysis and artifact subspace reconstruction methods, and show that some local quantities are handled better by our sample-adaptive real-time framework. Decoding performance is also compared with multi-day experimental data from 2 subjects, totaling 19 sessions, with and without [Formula: see text] filtering of the raw data. SIGNIFICANCE The proposed method allows real-time adaptive artifact removal for EEG-based closed-loop BMI applications and mobile EEG studies in general, thereby increasing the range of tasks that can be studied in action and context while reducing the need for discarding data due to artifacts. Significant increase in decoding performances also justify the effectiveness of the method to be used in real-time closed-loop BMI applications.

[1]  José Luis Contreras-Vidal,et al.  Decoding center-out hand velocity from MEG signals during visuomotor adaptation , 2009, NeuroImage.

[2]  José L. Contreras-Vidal,et al.  Magnetoencephalographic artifact identification and automatic removal based on independent component analysis and categorization approaches , 2006, Journal of Neuroscience Methods.

[3]  T. Ratnarajah,et al.  H/sup /spl infin// adaptive filters for eye blink artifact minimization from electroencephalogram , 2005, IEEE Signal Processing Letters.

[4]  Tzyy-Ping Jung,et al.  Real-time modeling and 3D visualization of source dynamics and connectivity using wearable EEG , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[5]  Thomas Kailath,et al.  H∞ adaptive filtering , 1995, ICASSP.

[6]  R. Barry,et al.  Removal of ocular artifact from the EEG: a review , 2000, Neurophysiologie Clinique/Clinical Neurophysiology.

[7]  Ángel Navia-Vázquez,et al.  Automatic removal of ocular artefacts using adaptive filtering and independent component analysis for electroencephalogram data , 2012, IET Signal Process..

[8]  Hasan Ayaz,et al.  A Methodology for Validating Artifact Removal Techniques for Physiological Signals , 2012, IEEE Transactions on Information Technology in Biomedicine.

[9]  Andrew H. Jazwinski,et al.  Adaptive filtering , 1969, Autom..

[10]  Saeed V. Vaseghi,et al.  Advanced Digital Signal Processing and Noise Reduction , 2006 .

[11]  S. Luck,et al.  The effects of electrode impedance on data quality and statistical significance in ERP recordings. , 2010, Psychophysiology.

[12]  Gary E. Birch,et al.  Effects of task and EEG-based reference signal on performance of on-line ocular artifact removal from real EEG , 2009, 2009 4th International IEEE/EMBS Conference on Neural Engineering.

[13]  D. Tucker,et al.  Scalp electrode impedance, infection risk, and EEG data quality , 2001, Clinical Neurophysiology.

[14]  Jose L. Contreras-Vidal,et al.  A closed-loop brain computer interface to a virtual reality avatar: Gait adaptation to visual kinematic perturbations , 2015, 2015 International Conference on Virtual Rehabilitation (ICVR).

[15]  Martin J. McKeown,et al.  Removing electroencephalographic artifacts: comparison between ICA and PCA , 1998, Neural Networks for Signal Processing VIII. Proceedings of the 1998 IEEE Signal Processing Society Workshop (Cat. No.98TH8378).

[16]  R. Ward,et al.  EMG and EOG artifacts in brain computer interface systems: A survey , 2007, Clinical Neurophysiology.

[17]  Seán F. McLoone,et al.  The Use of Ensemble Empirical Mode Decomposition With Canonical Correlation Analysis as a Novel Artifact Removal Technique , 2013, IEEE Transactions on Biomedical Engineering.

[18]  Atilla Kilicarslan,et al.  High accuracy decoding of user intentions using EEG to control a lower-body exoskeleton , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[19]  Tzyy-Ping Jung,et al.  Extended ICA Removes Artifacts from Electroencephalographic Recordings , 1997, NIPS.

[20]  Gustavo Deco,et al.  Coherent delta-band oscillations between cortical areas correlate with decision making , 2013, Proceedings of the National Academy of Sciences.

[21]  G. Wilson,et al.  Removal of ocular artifacts from electro-encephalogram by adaptive filtering , 2004, Medical and Biological Engineering and Computing.

[22]  Gary E. Birch,et al.  Quantitative evaluation of ocular artifact removal methods based on real and estimated EOG signals , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.