BackgroundFlow volume quantification in the great thoracic vessels is used in the assessment of several cardiovascular diseases. Clinically, it is often based on semi-automatic segmentation of a vessel throughout the cardiac cycle in 2D cine phase-contrast Cardiovascular Magnetic Resonance (CMR) images. Three-dimensional (3D), time-resolved phase-contrast CMR with three-directional velocity encoding (4D flow CMR) permits assessment of net flow volumes and flow patterns retrospectively at any location in a time-resolved 3D volume. However, analysis of these datasets can be demanding. The aim of this study is to develop and evaluate a fully automatic method for segmentation and analysis of 4D flow CMR data of the great thoracic vessels.MethodsThe proposed method utilizes atlas-based segmentation to segment the great thoracic vessels in systole, and registration between different time frames of the cardiac cycle in order to segment these vessels over time. Additionally, net flow volumes are calculated automatically at locations of interest. The method was applied on 4D flow CMR datasets obtained from 11 healthy volunteers and 10 patients with heart failure. Evaluation of the method was performed visually, and by comparison of net flow volumes in the ascending aorta obtained automatically (using the proposed method), and semi-automatically. Further evaluation was done by comparison of net flow volumes obtained automatically at different locations in the aorta, pulmonary artery, and caval veins.ResultsVisual evaluation of the generated segmentations resulted in good outcomes for all the major vessels in all but one dataset. The comparison between automatically and semi-automatically obtained net flow volumes in the ascending aorta resulted in very high correlation (r2=0.926). Moreover, comparison of the net flow volumes obtained automatically in other vessel locations also produced high correlations where expected: pulmonary trunk vs. proximal ascending aorta (r2=0.955), pulmonary trunk vs. pulmonary branches (r2=0.808), and pulmonary trunk vs. caval veins (r2=0.906).ConclusionsThe proposed method allows for automatic analysis of 4D flow CMR data, including vessel segmentation, assessment of flow volumes at locations of interest, and 4D flow visualization. This constitutes an important step towards facilitating the clinical utility of 4D flow CMR.

[1]  Heinz-Otto Peitgen,et al.  Fast interactive exploration of 4D MRI flow data , 2011, Medical Imaging.

[2]  Ilja Bezrukov,et al.  MRI-Based Attenuation Correction for Whole-Body PET/MRI: Quantitative Evaluation of Segmentation- and Atlas-Based Methods , 2011, The Journal of Nuclear Medicine.

[3]  Philipp Beerbaum,et al.  Systemic-to-pulmonary collateral flow in patients with palliated univentricular heart physiology: measurement using cardiovascular magnetic resonance 4D velocity acquisition , 2012, Journal of Cardiovascular Magnetic Resonance.

[4]  Raad Mohiaddin,et al.  How we perform cardiovascular magnetic resonance flow assessment using phase-contrast velocity mapping. , 2005, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[5]  Daniel Rueckert,et al.  Atlas-Based Segmentation and Tracking of 3D Cardiac MR Images Using Non-rigid Registration , 2002, MICCAI.

[6]  Petter Dyverfeldt,et al.  Higher order weighted least-squares phase offset correction for improved accuracy in phase-contrast MRI , 2008 .

[7]  Michael Lustig,et al.  Inlet and outlet valve flow and regurgitant volume may be directly and reliably quantified with accelerated, volumetric phase‐contrast MRI , 2015, Journal of magnetic resonance imaging : JMRI.

[8]  Hans Knutsson,et al.  Morphons: Paint on Priors and Elastic Canvas for Segmentation and Registration , 2005, SCIA.

[9]  J Valk,et al.  An in vivo validation of quantitative blood flow imaging in arteries and veins using magnetic resonance phase-shift techniques. , 1991, European heart journal.

[10]  Kecheng Liu,et al.  A review on MR vascular image processing: skeleton versus nonskeleton approaches: part II , 2002, IEEE Transactions on Information Technology in Biomedicine.

[11]  Isabelle Bloch,et al.  A review of 3D vessel lumen segmentation techniques: Models, features and extraction schemes , 2009, Medical Image Anal..

[12]  V. Lee,et al.  Cardiovascular applications of phase-contrast MRI. , 2009, AJR. American journal of roentgenology.

[13]  Torsten Rohlfing,et al.  Quo Vadis, Atlas-Based Segmentation? , 2005 .

[14]  P. Turski,et al.  Four-dimensional phase contrast magnetic resonance angiography: potential clinical applications. , 2011, European journal of radiology.

[15]  Hans Knutsson,et al.  Morphons: segmentation using elastic canvas and paint on priors , 2005, IEEE International Conference on Image Processing 2005.

[16]  P. Walker,et al.  Evaluation of the precision of magnetic resonance phase velocity mapping for blood flow measurements. , 2001, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[17]  Marcel Breeuwer,et al.  Interactive Virtual Probing of 4D MRI Blood-Flow , 2011, IEEE Transactions on Visualization and Computer Graphics.

[18]  I. T. Jolliffe,et al.  Springer series in statistics , 1986 .

[19]  Meritxell Bach Cuadra,et al.  A review of atlas-based segmentation for magnetic resonance brain images , 2011, Comput. Methods Programs Biomed..

[20]  Huy Nguyen,et al.  Automated segmentation of blood-flow regions in large thoracic arteries using 3D-cine PC-MRI measurements , 2012, International Journal of Computer Assisted Radiology and Surgery.

[21]  Steffen Ringgaard,et al.  Three dimensional three component whole heart cardiovascular magnetic resonance velocity mapping: comparison of flow measurements from 3D and 2D acquisitions , 2009, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[22]  S. Ley,et al.  Magnetic resonance assessment of pulmonary (QP) to systemic (QS) flows using 4D phase-contrast imaging: pilot study comparison with standard through-plane 2D phase-contrast imaging. , 2014, Academic radiology.

[23]  Hans Knutsson,et al.  Using the Local Phase of the Magnitude of the Local Structure Tensor for Image Registration , 2011, SCIA.

[24]  Q. Xiang,et al.  Temporal phase unwrapping for cine velocity imaging , 1995, Journal of magnetic resonance imaging : JMRI.

[25]  Hans Knutsson,et al.  Phase-Based Non-Rigid 3D Image Registration - From Minutes to Seconds Using CUDA , 2011, HPDC 2011.

[26]  Hans Knutsson,et al.  Non-rigid Registration Using Morphons , 2005, SCIA.

[27]  J. Hennig,et al.  4D phase contrast MRI at 3 T: Effect of standard and blood‐pool contrast agents on SNR, PC‐MRA, and blood flow visualization , 2010, Magnetic resonance in medicine.

[28]  Daniel Forsberg,et al.  Robust Image Registration for Improved Clinical Efficiency : Using Local Structure Analysis and Model-Based Processing , 2013 .

[29]  Valerie Duay,et al.  Atlas-based Segmentation , 2015 .

[30]  J. Hennig,et al.  Quantitative 2D and 3D phase contrast MRI: Optimized analysis of blood flow and vessel wall parameters , 2008, Magnetic resonance in medicine.

[31]  David Saloner,et al.  Clinical evaluation of aortic coarctation with 4D flow MR imaging , 2010, Journal of magnetic resonance imaging : JMRI.